Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime. Philips Intellispace Portal Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Philips Intellispace Portal can process clinical images from different modes and enables advanced visualization of the images. ISP systems are deployed in the healthcare and public health sectors. 1. A remote code-execution vulnerability 2. Multiple privilege-escalation vulnerabilities 3. A cryptographic security vulnerability Attackers can exploit these issues to execute arbitrary code within the context of affected device, cause a denial-of-service condition, bypass certain security restrictions, obtain sensitive information or gain unauthorized access to the device and perform unauthorized actions. This may lead to complete compromise of the device. Intellispace Portal versions 8.0.x and 7.0.x are vulnerable. The system provides viewing of echographic images and a single point of access for physicians. Permission and access control vulnerabilities exist in Philips ISP versions 8.0.x and 7.0.x
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201803-2082", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "intellispace portal", "scope": "eq", "trust": 1.9, "vendor": "philips", "version": "8.0" }, { "model": "intellispace portal", "scope": "eq", "trust": 1.6, "vendor": "philips", "version": "9.0" }, { "model": "intellispace portal", "scope": "eq", "trust": 1.4, "vendor": "philips", "version": "8.0.x" }, { "model": "intellispace portal", "scope": "eq", "trust": 1.4, "vendor": "philips", "version": "7.0.x" }, { "model": "intellispace portal", "scope": "eq", "trust": 0.3, "vendor": "philips", "version": "7.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "BID", "id": "103182" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-5454" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vendor reported this issue.", "sources": [ { "db": "BID", "id": "103182" } ], "trust": 0.3 }, "cve": "CVE-2018-5454", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2018-5454", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-03810", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-135485", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-5454", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-5454", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2018-03810", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201803-775", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-135485", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "VULHUB", "id": "VHN-135485" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime. Philips Intellispace Portal Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Philips Intellispace Portal can process clinical images from different modes and enables advanced visualization of the images. ISP systems are deployed in the healthcare and public health sectors. \n1. A remote code-execution vulnerability\n2. Multiple privilege-escalation vulnerabilities\n3. A cryptographic security vulnerability\nAttackers can exploit these issues to execute arbitrary code within the context of affected device, cause a denial-of-service condition, bypass certain security restrictions, obtain sensitive information or gain unauthorized access to the device and perform unauthorized actions. This may lead to complete compromise of the device. \nIntellispace Portal versions 8.0.x and 7.0.x are vulnerable. The system provides viewing of echographic images and a single point of access for physicians. Permission and access control vulnerabilities exist in Philips ISP versions 8.0.x and 7.0.x", "sources": [ { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "BID", "id": "103182" }, { "db": "VULHUB", "id": "VHN-135485" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-5454", "trust": 3.4 }, { "db": "ICS CERT", "id": "ICSMA-18-058-02", "trust": 3.4 }, { "db": "BID", "id": "103182", "trust": 2.0 }, { "db": "JVNDB", "id": "JVNDB-2018-003324", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201803-775", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2018-03810", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-135485", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "VULHUB", "id": "VHN-135485" }, { "db": "BID", "id": "103182" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "id": "VAR-201803-2082", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-135485" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T11:38:32.327000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Philips IntelliSpace Portal Vulnerabilities (26-FEB-2018)", "trust": 0.8, "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security" }, { "title": "Patch for Philips Intellispace Portal Arbitrary Code Execution Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/119247" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-264", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-135485" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "https://ics-cert.us-cert.gov/advisories/icsma-18-058-02" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/103182" }, { "trust": 1.7, "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5454" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-5454" }, { "trust": 0.3, "url": "http://www.usa.philips.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "VULHUB", "id": "VHN-135485" }, { "db": "BID", "id": "103182" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2018-03810" }, { "db": "VULHUB", "id": "VHN-135485" }, { "db": "BID", "id": "103182" }, { "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "db": "NVD", "id": "CVE-2018-5454" }, { "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-02-28T00:00:00", "db": "CNVD", "id": "CNVD-2018-03810" }, { "date": "2018-03-26T00:00:00", "db": "VULHUB", "id": "VHN-135485" }, { "date": "2018-02-27T00:00:00", "db": "BID", "id": "103182" }, { "date": "2018-05-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "date": "2018-03-26T14:29:00.213000", "db": "NVD", "id": "CVE-2018-5454" }, { "date": "2018-03-22T00:00:00", "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-02-28T00:00:00", "db": "CNVD", "id": "CNVD-2018-03810" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-135485" }, { "date": "2018-02-27T00:00:00", "db": "BID", "id": "103182" }, { "date": "2018-05-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-003324" }, { "date": "2019-10-09T23:41:23.500000", "db": "NVD", "id": "CVE-2018-5454" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201803-775" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201803-775" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Philips Intellispace Portal Vulnerabilities related to authorization, permissions, and access control", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-003324" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "permissions and access control issues", "sources": [ { "db": "CNNVD", "id": "CNNVD-201803-775" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.