VAR-201805-0519
Vulnerability from variot - Updated: 2023-12-18 14:05A vulnerability in the detection engine of Cisco Firepower System Software could allow an unauthenticated, remote attacker to restart an instance of the Snort detection engine on an affected device, resulting in a brief denial of service (DoS) condition. The vulnerability is due to the incorrect handling of Transport Layer Security (TLS) TCP connection setup for the affected software. An attacker could exploit this vulnerability by sending crafted TLS traffic to an affected device. A successful exploit could allow the attacker to cause the Snort detection engine on the affected device to restart, resulting in a DoS condition. Cisco Bug IDs: CSCvg99327. Cisco Firepower System The software contains cryptographic vulnerabilities. Vendors have confirmed this vulnerability Bug ID CSCvg99327 It is released as.Service operation interruption (DoS) There is a possibility of being put into a state. The detection engine is one of the intrusion detection engines
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201805-0519",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "firepower management center",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "6.2.3"
},
{
"model": "firepower management center",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "6.2.2"
},
{
"model": "firepower management center",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "6.1.0"
},
{
"model": "firepower management center",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "6.2.0"
},
{
"model": "firepower management center",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "firepower system software",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "0"
}
],
"sources": [
{
"db": "BID",
"id": "104121"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.2.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.2.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-0283"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "104121"
}
],
"trust": 0.3
},
"cve": "CVE-2018-0283",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-0283",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-118485",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "Low",
"baseScore": 5.8,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2018-0283",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-0283",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201805-077",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-118485",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118485"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the detection engine of Cisco Firepower System Software could allow an unauthenticated, remote attacker to restart an instance of the Snort detection engine on an affected device, resulting in a brief denial of service (DoS) condition. The vulnerability is due to the incorrect handling of Transport Layer Security (TLS) TCP connection setup for the affected software. An attacker could exploit this vulnerability by sending crafted TLS traffic to an affected device. A successful exploit could allow the attacker to cause the Snort detection engine on the affected device to restart, resulting in a DoS condition. Cisco Bug IDs: CSCvg99327. Cisco Firepower System The software contains cryptographic vulnerabilities. Vendors have confirmed this vulnerability Bug ID CSCvg99327 It is released as.Service operation interruption (DoS) There is a possibility of being put into a state. The detection engine is one of the intrusion detection engines",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "BID",
"id": "104121"
},
{
"db": "VULHUB",
"id": "VHN-118485"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-0283",
"trust": 2.8
},
{
"db": "BID",
"id": "104121",
"trust": 2.0
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-118485",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118485"
},
{
"db": "BID",
"id": "104121"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"id": "VAR-201805-0519",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-118485"
}
],
"trust": 0.6369458
},
"last_update_date": "2023-12-18T14:05:27.642000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-20180502-fpwr-codp",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20180502-fpwr-codp"
},
{
"title": "Cisco Firepower System Software detection Fixes for engine encryption problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79813"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.1
},
{
"problemtype": "CWE-310",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118485"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20180502-fpwr-codp"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/104121"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-0283"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-0283"
},
{
"trust": 0.3,
"url": "http://www.cisco.com/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118485"
},
{
"db": "BID",
"id": "104121"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-118485"
},
{
"db": "BID",
"id": "104121"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-05-02T00:00:00",
"db": "VULHUB",
"id": "VHN-118485"
},
{
"date": "2018-05-02T00:00:00",
"db": "BID",
"id": "104121"
},
{
"date": "2018-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"date": "2018-05-02T22:29:01.120000",
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"date": "2018-05-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-118485"
},
{
"date": "2018-05-02T00:00:00",
"db": "BID",
"id": "104121"
},
{
"date": "2018-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-004608"
},
{
"date": "2019-10-09T23:31:38.443000",
"db": "NVD",
"id": "CVE-2018-0283"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Firepower System Cryptographic vulnerabilities in software",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-004608"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201805-077"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.