var-201807-1850
Vulnerability from variot
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server. Schneider Electric U.motion Builder Software Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. U.motion Builder is a generator product from Schneider Electric, France
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1850", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "u.motion builder", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "1.3.4" }, { "model": "u.motion builder software", "scope": "lt", "trust": 0.8, "vendor": "schneider electric", "version": "1.3.4" }, { "model": "electric u.motion builder", "scope": "lt", "trust": 0.6, "vendor": "schneider", "version": "1.3.4" }, { "model": "u.motion builder", "scope": "eq", "trust": 0.6, "vendor": "schneider electric", "version": "1.2.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "u motion builder", "version": "*" } ], "sources": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.4", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-7777" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cosmin Craciun", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-149" } ], "trust": 0.6 }, "cve": "CVE-2018-7777", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2018-7777", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2018-07816", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "e2ebb601-39ab-11e9-b061-000c29342cb1", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-7777", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-7777", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2018-07816", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201807-149", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1", "trust": 0.2, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server. Schneider Electric U.motion Builder Software Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. U.motion Builder is a generator product from Schneider Electric, France", "sources": [ { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-7777", "trust": 3.2 }, { "db": "SCHNEIDER", "id": "SEVD-2018-095-01", "trust": 2.2 }, { "db": "PACKETSTORM", "id": "156184", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2018-07816", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201807-149", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-180-02", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-007236", "trust": 0.8 }, { "db": "EXPLOIT-DB", "id": "47991", "trust": 0.6 }, { "db": "IVD", "id": "E2EBB601-39AB-11E9-B061-000C29342CB1", "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "id": "VAR-201807-1850", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" } ], "trust": 1.8 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" } ] }, "last_update_date": "2023-12-18T10:59:33.665000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SEVD-2018-095-01", "trust": 0.8, "url": "https://www.schneider-electric.com/en/download/document/sevd-2018-095-01/" }, { "title": "Patch for Schneider Electric U.motion Builder Remote Code Execution Vulnerability (CNVD-2018-07816)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/125973" }, { "title": "Schneider Electric U.motion Builder Repair measures for software security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=81718" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "http://packetstormsecurity.com/files/156184/schneider-electric-u.motion-builder-1.3.4-command-injection.html" }, { "trust": 1.6, "url": "https://www.schneider-electric.com/en/download/document/sevd-2018-095-01/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7777" }, { "trust": 0.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-180-02" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7777" }, { "trust": 0.6, "url": "https://download.schneider-electric.com/files?p_endoctype=technical+leaflet\u0026p_file_id=9607472623\u0026p_file_name=sevd-2018-095-01+u.motion.pdf\u0026p_reference=sevd-2018-095-01" }, { "trust": 0.6, "url": "https://www.exploit-db.com/exploits/47991" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-07816" }, { "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "db": "NVD", "id": "CVE-2018-7777" }, { "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-04-18T00:00:00", "db": "IVD", "id": "e2ebb601-39ab-11e9-b061-000c29342cb1" }, { "date": "2018-04-18T00:00:00", "db": "CNVD", "id": "CNVD-2018-07816" }, { "date": "2018-09-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "date": "2018-07-03T14:29:01.163000", "db": "NVD", "id": "CVE-2018-7777" }, { "date": "2018-07-04T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-04-18T00:00:00", "db": "CNVD", "id": "CNVD-2018-07816" }, { "date": "2019-01-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-007236" }, { "date": "2020-02-03T19:15:11.897000", "db": "NVD", "id": "CVE-2018-7777" }, { "date": "2020-02-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-149" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-149" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Schneider Electric U.motion Builder Software Input validation vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-007236" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-149" } ], "trust": 0.6 } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.