VAR-201807-1860

Vulnerability from variot - Updated: 2023-12-18 11:49

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. A stack-based buffer-overflow vulnerability 2. An OS command-injection vulnerability 3. A cross-site scripting vulnerability 4. An information-disclosure vulnerability Exploiting these issues could allow an attacker to bypass authentication mechanism, to execute arbitrary script code in the browser of an unsuspecting user, obtain sensitive information, execute arbitrary code and perform unauthorized actions. Failed exploits can result in a denial-of-service condition. Versions prior to U.motion Builder 1.3.4 are vulnerable

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1860",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "u.motion builder",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "1.3.4"
      },
      {
        "model": "u.motion builder",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "schneider electric",
        "version": "1.2.1"
      },
      {
        "model": "u.motion builder software",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "1.3.4"
      },
      {
        "model": "electric u.motion builder",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "1.3.4"
      },
      {
        "model": "u.motion builder",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "1.0.1"
      },
      {
        "model": "u.motion builder",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "1.3.4"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "u motion builder",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "BID",
        "id": "104447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "1.3.4",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Wei Gao of Ixia and bigric3@360A-TEAM",
    "sources": [
      {
        "db": "BID",
        "id": "104447"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-7787",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": true,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2018-7787",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-11390",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2018-7787",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-7787",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-11390",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201806-1169",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. A stack-based buffer-overflow vulnerability\n2. An OS command-injection vulnerability\n3. A cross-site scripting vulnerability\n4. An information-disclosure vulnerability\nExploiting these issues could allow an attacker to bypass authentication mechanism, to execute arbitrary script code in the browser of an unsuspecting user, obtain sensitive information, execute arbitrary code and perform unauthorized actions. Failed exploits can result in a denial-of-service condition. \nVersions prior to U.motion Builder 1.3.4 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "BID",
        "id": "104447"
      },
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      }
    ],
    "trust": 2.61
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-7787",
        "trust": 3.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-163-01",
        "trust": 2.3
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2018-151-01",
        "trust": 1.9
      },
      {
        "db": "BID",
        "id": "104447",
        "trust": 1.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "40191",
        "trust": 0.6
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2017-178-01",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "E2F293D1-39AB-11E9-AC4A-000C29342CB1",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "BID",
        "id": "104447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "id": "VAR-201807-1860",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      }
    ],
    "trust": 1.8
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:49:26.670000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SEVD-2018-151-01",
        "trust": 0.8,
        "url": "https://www.schneider-electric.com/en/download/document/sevd-2018-151-01/"
      },
      {
        "title": "Patch for Schneider Electric U.motion Builder Information Disclosure Vulnerability (CNVD-2018-11390)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/131855"
      },
      {
        "title": "Schneider Electric U.motion Builder Enter the fix for the verification vulnerability",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=81474"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-163-01"
      },
      {
        "trust": 1.9,
        "url": "https://www.schneider-electric.com/en/download/document/sevd-2018-151-01/"
      },
      {
        "trust": 1.0,
        "url": "http://www.securityfocus.com/bid/104447"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7787"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7787"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/40191"
      },
      {
        "trust": 0.3,
        "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
      },
      {
        "trust": 0.3,
        "url": "http://www.schneider-electric.com/en/download/document/sevd-2017-178-01/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "BID",
        "id": "104447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "db": "BID",
        "id": "104447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-06-13T00:00:00",
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "date": "2018-06-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "date": "2018-06-12T00:00:00",
        "db": "BID",
        "id": "104447"
      },
      {
        "date": "2018-09-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "date": "2018-07-03T14:29:01.680000",
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "date": "2018-06-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-06-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-11390"
      },
      {
        "date": "2018-06-12T00:00:00",
        "db": "BID",
        "id": "104447"
      },
      {
        "date": "2018-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      },
      {
        "date": "2018-08-28T13:45:30.080000",
        "db": "NVD",
        "id": "CVE-2018-7787"
      },
      {
        "date": "2018-06-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider Electric U.motion Builder Software Input validation vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007239"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation",
    "sources": [
      {
        "db": "IVD",
        "id": "e2f293d1-39ab-11e9-ac4a-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1169"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…