Vulnerability from variot - Updated: 2023-12-18 13:52Dell WMS versions 1.1 and prior are impacted by multiple unquoted service path vulnerabilities. Affected software installs multiple services incorrectly by specifying the paths to the service executables without quotes. This could potentially allow a low-privileged local user to execute arbitrary executables with elevated privileges. Dell Wyse Management Suite (WMS) is a scalable solution for managing and optimizing Wyse endpoints from Dell. The offering includes centralized Wyse endpoint management, asset tracking and automatic device discovery, among others
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0598",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wyse management suite",
"scope": "lte",
"trust": 1.8,
"vendor": "dell",
"version": "1.1"
},
{
"model": "wyse management suite",
"scope": "eq",
"trust": 0.6,
"vendor": "dell",
"version": "1.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:pro:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:standard:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11063"
}
]
},
"cve": "CVE-2018-11063",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.6,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-11063",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-120885",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-11063",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-11063",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-280",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-120885",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-120885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell WMS versions 1.1 and prior are impacted by multiple unquoted service path vulnerabilities. Affected software installs multiple services incorrectly by specifying the paths to the service executables without quotes. This could potentially allow a low-privileged local user to execute arbitrary executables with elevated privileges. Dell Wyse Management Suite (WMS) is a scalable solution for managing and optimizing Wyse endpoints from Dell. The offering includes centralized Wyse endpoint management, asset tracking and automatic device discovery, among others",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "VULHUB",
"id": "VHN-120885"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-11063",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-120885",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-120885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"id": "VAR-201808-0598",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-120885"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:52:33.655000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Wyse Management Suite Multiple Unquoted Service Path Vulnerabilities",
"trust": 0.8,
"url": "https://www.dell.com/support/article/jp/ja/jpbsd1/sln313398/dell-wyse-management-suite-multiple-unquoted-service-path-vulnerabilities?lang=en"
},
{
"title": "Dell Wyse Management Suite Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=83906"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-428",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-120885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://www.dell.com/support/article/us/en/19/sln313398/dell-wyse-management-suite-multiple-unquoted-service-path-vulnerabilities?lang=en"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11063"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-11063"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-120885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-120885"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-10T00:00:00",
"db": "VULHUB",
"id": "VHN-120885"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"date": "2018-08-10T20:29:00.353000",
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"date": "2018-08-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-16T00:00:00",
"db": "VULHUB",
"id": "VHN-120885"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009205"
},
{
"date": "2018-10-16T17:09:36.080000",
"db": "NVD",
"id": "CVE-2018-11063"
},
{
"date": "2018-08-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell WMS Vulnerabilities related to unquoted search paths or elements",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009205"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "lack of information",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-280"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…