GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

VAR-201903-0182

Vulnerability from variot - Updated: 2023-12-18 13:33

ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition. ENTTEC Datagate MK2 , Storm 24 , Pixelator Is vulnerable to a lack of authentication for critical functions.Service operation interruption (DoS) There is a possibility of being put into a state. ENTTECDatagateMK2 and other products are products of Australian ENTTEC company. The ENTTECDatagateMK2 is a lighting controller. The ENTTECStorm24 is an Ethernet to DMX512 converter. The ENTTECPixelator is a pixel controller. ENTTEC Lighting Controllers are prone to a remote denial-of-service vulnerability. Attackers can exploit this issue to reboot the affected device, denying service to legitimate users. The following ENTTEC products and versions are affected: Datagate MK2 all versions prior to 70044-update-05032019-482, Storm 24 all versions prior to 70050-update-05032019-482, and Pixelator all versions prior to 70060-update-05032019-482

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201903-0182",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "datagate mk2",
        "scope": "lt",
        "trust": 1.8,
        "vendor": "enttec",
        "version": "70044_update_05032019-482"
      },
      {
        "model": "pixelator",
        "scope": "lt",
        "trust": 1.8,
        "vendor": "enttec",
        "version": "70060_update_05032019-482"
      },
      {
        "model": "storm 24",
        "scope": "lt",
        "trust": 1.8,
        "vendor": "enttec",
        "version": "70050_update_05032019-482"
      },
      {
        "model": "datagate mk2 \u003c70044 update 05032019-482",
        "scope": null,
        "trust": 0.6,
        "vendor": "enttec",
        "version": null
      },
      {
        "model": "storm \u003c70050 update 05032019-482",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "enttec",
        "version": "24"
      },
      {
        "model": "pixelator \u003c70060 update 05032019-482",
        "scope": null,
        "trust": 0.6,
        "vendor": "enttec",
        "version": null
      },
      {
        "model": "storm",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "240"
      },
      {
        "model": "pixelator",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "0"
      },
      {
        "model": "datagate mk2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "0"
      },
      {
        "model": "storm update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "24700500503201"
      },
      {
        "model": "pixelator update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "700600503201"
      },
      {
        "model": "datagate mk2 update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "enttec",
        "version": "700440503201"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "datagate mk2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "storm 24",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pixelator",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "BID",
        "id": "107592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:enttec:datagate_mk2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "70044_update_05032019-482",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:enttec:datagate_mk2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:enttec:storm_24_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "70050_update_05032019-482",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:enttec:storm_24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:enttec:pixelator_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "70060_update_05032019-482",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:enttec:pixelator:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ankit Anubhav of NewSky Security reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6542",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6542",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-08969",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "ce3903e4-75e5-4a41-9971-a43166124523",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6542",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2019-6542",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-08969",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201903-1045",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "ce3903e4-75e5-4a41-9971-a43166124523",
            "trust": 0.2,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition. ENTTEC Datagate MK2 , Storm 24 , Pixelator Is vulnerable to a lack of authentication for critical functions.Service operation interruption (DoS) There is a possibility of being put into a state. ENTTECDatagateMK2 and other products are products of Australian ENTTEC company. The ENTTECDatagateMK2 is a lighting controller. The ENTTECStorm24 is an Ethernet to DMX512 converter. The ENTTECPixelator is a pixel controller. ENTTEC Lighting Controllers are prone to a remote denial-of-service vulnerability. \nAttackers can exploit this issue to reboot the affected device, denying service to legitimate users. \nThe following ENTTEC products and versions are affected:\nDatagate MK2 all versions prior to 70044-update-05032019-482,\nStorm 24 all versions prior to 70050-update-05032019-482, and\nPixelator all versions prior to 70060-update-05032019-482",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "BID",
        "id": "107592"
      },
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      }
    ],
    "trust": 2.61
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6542",
        "trust": 3.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-085-03",
        "trust": 3.3
      },
      {
        "db": "BID",
        "id": "107592",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1012",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "CE3903E4-75E5-4A41-9971-A43166124523",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "BID",
        "id": "107592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "id": "VAR-201903-0182",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      }
    ],
    "trust": 1.8
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:33:33.455000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Datagate MK2",
        "trust": 0.8,
        "url": "https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/advanced-lighting-data-control/"
      },
      {
        "title": "Storm 24",
        "trust": 0.8,
        "url": "https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/ethernet-to-dmx-converter/"
      },
      {
        "title": "Pixelator",
        "trust": 0.8,
        "url": "https://www.enttec.com/product/controls/addressable-led-pixel-control/24-port-ethernet-pixel-controller/"
      },
      {
        "title": "Patch for ENTTECDatagateMK2, Storm24, and Pixelator Denial of Service Vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/158069"
      },
      {
        "title": "ENTTEC Datagate MK2 , Storm 24  and Pixelator Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=90466"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-085-03-0"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6542"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6542"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/77906"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/107592"
      },
      {
        "trust": 0.3,
        "url": "https://www.enttec.com/products/network-and-distribution/dmx512-conversion/advanced-lighting-data-control/"
      },
      {
        "trust": 0.3,
        "url": "https://www.enttec.com/as/"
      },
      {
        "trust": 0.3,
        "url": "https://www.enttec.com/products/led-pixel-drivers/led-pixel-strip-driver/ethernet-to-pixel-converter/"
      },
      {
        "trust": 0.3,
        "url": "https://www.enttec.com/products/network-and-distribution/dmx512-conversion/ethernet-to-dmx-converter/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "BID",
        "id": "107592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "db": "BID",
        "id": "107592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-03T00:00:00",
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "date": "2019-04-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "BID",
        "id": "107592"
      },
      {
        "date": "2019-05-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "date": "2019-03-28T14:29:00.367000",
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-08969"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "BID",
        "id": "107592"
      },
      {
        "date": "2019-05-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      },
      {
        "date": "2023-01-31T21:04:05.680000",
        "db": "NVD",
        "id": "CVE-2019-6542"
      },
      {
        "date": "2019-10-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  ENTTEC Vulnerability related to lack of certification for critical functions in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003105"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Access control error",
    "sources": [
      {
        "db": "IVD",
        "id": "ce3903e4-75e5-4a41-9971-a43166124523"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-1045"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…