VAR-201903-0906
Vulnerability from variot - Updated: 2023-12-18 12:01An exploitable buffer overflow vulnerability exists in the PubNub message handler Insteon Hub 2245-222 - Firmware version 1012 for the cc channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker can send an authenticated HTTP request At 0x9d014dd8 the value for the id key is copied using strcpy to the buffer at $sp+0x290. This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. An attacker could exploit the vulnerability to cover any data by sending an authenticated request
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0906",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hub",
"scope": "eq",
"trust": 2.4,
"vendor": "insteon",
"version": "1012"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:insteon:hub:2245-222:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-16253"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Discovered by Claudio Bozzato of Cisco Talos.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
],
"trust": 0.6
},
"cve": "CVE-2017-16253",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.5,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-16253",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-13144",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-107157",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "talos-cna@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-16253",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-16253",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2017-16253",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-16253",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2019-13144",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201711-175",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-107157",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An exploitable buffer overflow vulnerability exists in the PubNub message handler Insteon Hub 2245-222 - Firmware version 1012 for the cc channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker can send an authenticated HTTP request At 0x9d014dd8 the value for the id key is copied using strcpy to the buffer at $sp+0x290. This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. An attacker could exploit the vulnerability to cover any data by sending an authenticated request",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "TALOS",
"id": "TALOS-2017-0483",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2017-16253",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201711-175",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-13144",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-107157",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"id": "VAR-201903-0906",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
}
],
"trust": 1.3825397
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": "Gateway / Hub: Open Ecosystem",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
}
]
},
"last_update_date": "2023-12-18T12:01:21.580000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Insteon Hub",
"trust": 0.8,
"url": "https://www.insteon.com/insteon-hub"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-107157"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2017-0483"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-16253"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16253"
},
{
"trust": 0.6,
"url": "https://www.talosintelligence.com/vulnerability_reports/talos-2017-0483"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"db": "VULHUB",
"id": "VHN-107157"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"date": "2019-03-21T00:00:00",
"db": "VULHUB",
"id": "VHN-107157"
},
{
"date": "2019-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"date": "2019-03-21T17:29:00.243000",
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"date": "2017-10-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-13144"
},
{
"date": "2022-12-09T00:00:00",
"db": "VULHUB",
"id": "VHN-107157"
},
{
"date": "2019-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014405"
},
{
"date": "2022-12-09T02:33:07.640000",
"db": "NVD",
"id": "CVE-2017-16253"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Insteon Hub Firmware buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014405"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-175"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.