var-201906-0289
Vulnerability from variot
A vulnerability in the BIOS upgrade utility of Cisco Unified Computing System (UCS) C-Series Rack Servers could allow an authenticated, local attacker to install compromised BIOS firmware on an affected device. The vulnerability is due to insufficient validation of the firmware image file. An attacker could exploit this vulnerability by executing the BIOS upgrade utility with a specific set of options. A successful exploit could allow the attacker to bypass the firmware signature-verification process and install compromised BIOS firmware on an affected device. Cisco Unified Computing System (UCS) C-Series Rack Server Contains vulnerabilities related to insufficient validation of data reliability.Information may be tampered with. Cisco Unified Computing System Central Software is prone to a security-bypass Vulnerability. Attackers can exploit this issue to bypass certain security restrictions to perform unauthorized actions. This issue being tracked by Cisco Bug IDs CSCvp12824, CSCvp12840
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201906-0289", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "unified computing system server", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "3.0\\(4l\\)" }, { "model": "unified computing system server", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "4.0\\(4c\\)" }, { "model": "unified computing system server", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "4.0\\(2g\\)" }, { "model": "unified computing system server", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "4.0" }, { "model": "industrial network director", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "unified computing system 4.0 s7", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "unified computing system 3.0 h", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "ucs c-series rack servers 4.0 hs3", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null } ], "sources": [ { "db": "BID", "id": "108680" }, { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(2g\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c125_m5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(2g\\)", "versionStartIncluding": "4.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.0\\(4l\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c220_m4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(4c\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c220_m5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(2g\\)", "versionStartIncluding": "4.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.0\\(4l\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c240_m4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(4c\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c240_m5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(2g\\)", "versionStartIncluding": "4.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.0\\(4l\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c460_m4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:unified_computing_system_server_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0\\(4c\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:unified_computing_system_c480_m5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-1880" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco", "sources": [ { "db": "BID", "id": "108680" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ], "trust": 0.9 }, "cve": "CVE-2019-1880", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 2.1, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-1880", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 0.8, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.4, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-1880", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-1880", "trust": 1.8, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2019-1880", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201906-153", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the BIOS upgrade utility of Cisco Unified Computing System (UCS) C-Series Rack Servers could allow an authenticated, local attacker to install compromised BIOS firmware on an affected device. The vulnerability is due to insufficient validation of the firmware image file. An attacker could exploit this vulnerability by executing the BIOS upgrade utility with a specific set of options. A successful exploit could allow the attacker to bypass the firmware signature-verification process and install compromised BIOS firmware on an affected device. Cisco Unified Computing System (UCS) C-Series Rack Server Contains vulnerabilities related to insufficient validation of data reliability.Information may be tampered with. Cisco Unified Computing System Central Software is prone to a security-bypass Vulnerability. \nAttackers can exploit this issue to bypass certain security restrictions to perform unauthorized actions. \nThis issue being tracked by Cisco Bug IDs CSCvp12824, CSCvp12840", "sources": [ { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "BID", "id": "108680" } ], "trust": 1.89 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-1880", "trust": 2.7 }, { "db": "BID", "id": "108680", "trust": 1.9 }, { "db": "JVNDB", "id": "JVNDB-2019-005281", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2020.0766", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.2028", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201906-153", "trust": 0.6 } ], "sources": [ { "db": "BID", "id": "108680" }, { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "id": "VAR-201906-0289", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.53846157 }, "last_update_date": "2023-12-18T11:06:59.241000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20190605-ucs-biossig-bypass", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190605-ucs-biossig-bypass" }, { "title": "Cisco Unified Computing System C-Series Rack Servers Repair measures for data forgery problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=93245" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-345", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "http://www.securityfocus.com/bid/108680" }, { "trust": 1.9, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190605-ucs-biossig-bypass" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-1880" }, { "trust": 0.9, "url": "http://www.cisco.com/c/en/us/support/servers-unified-computing/ucs-central-software/tsd-products-support-series-home.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-1880" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.0766/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.2028/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/cisco-unified-computing-system-privilege-escalation-via-bios-upgrade-29477" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "BID", "id": "108680" }, { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "BID", "id": "108680" }, { "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "db": "NVD", "id": "CVE-2019-1880" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-06-05T00:00:00", "db": "BID", "id": "108680" }, { "date": "2019-06-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "date": "2019-06-05T17:29:00.647000", "db": "NVD", "id": "CVE-2019-1880" }, { "date": "2019-06-05T00:00:00", "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-06-05T00:00:00", "db": "BID", "id": "108680" }, { "date": "2019-06-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-005281" }, { "date": "2019-10-09T23:48:25.190000", "db": "NVD", "id": "CVE-2019-1880" }, { "date": "2020-03-04T00:00:00", "db": "CNNVD", "id": "CNNVD-201906-153" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "BID", "id": "108680" }, { "db": "CNNVD", "id": "CNNVD-201906-153" } ], "trust": 0.9 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Unified Computing System C-Series Rack Server Vulnerabilities related to insufficient validation of data reliability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-005281" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "data forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-201906-153" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.