VAR-201910-0345
Vulnerability from variot - Updated: 2023-12-18 11:59A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to access sensitive information on an affected device. The vulnerability is due to unsafe handling of user credentials. An attacker could exploit this vulnerability by viewing portions of the web-based management interface of an affected device. A successful exploit could allow the attacker to access administrative credentials and potentially gain elevated privileges by reusing stolen credentials on the affected device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201910-0345",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "spa122",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "1.4.1"
},
{
"model": "spa112",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "1.4.1"
},
{
"model": "spa122",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.1"
},
{
"model": "spa112",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.1"
},
{
"model": "spa 112",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "spa 122",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "spa100 series sr3",
"scope": "lte",
"trust": 0.6,
"vendor": "cisco",
"version": "\u003c=1.4.1"
},
{
"model": "spa112",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": null
},
{
"model": "spa122",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:spa112:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:spa122:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-12708"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Andrew Orr and Alex Weber of Tenable Inc. .",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
],
"trust": 0.6
},
"cve": "CVE-2019-12708",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-12708",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-36893",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ykramarz@cisco.com",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-12708",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-12708",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "ykramarz@cisco.com",
"id": "CVE-2019-12708",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-36893",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201910-1091",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to access sensitive information on an affected device. The vulnerability is due to unsafe handling of user credentials. An attacker could exploit this vulnerability by viewing portions of the web-based management interface of an affected device. A successful exploit could allow the attacker to access administrative credentials and potentially gain elevated privileges by reusing stolen credentials on the affected device",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "CNVD",
"id": "CNVD-2019-36893"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-12708",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2019-44",
"trust": 1.6
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-36893",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2019.3878",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"id": "VAR-201910-0345",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
}
]
},
"last_update_date": "2023-12-18T11:59:21.576000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-20191016-spa-credentials",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-credentials"
},
{
"title": "Patch for Cisco SPA100 Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/186441"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-credentials"
},
{
"trust": 1.6,
"url": "https://www.tenable.com/security/research/tra-2019-44"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-12708"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-12708"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-ui-disclosure"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-webui-dos"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-running-config"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-rce"
},
{
"trust": 0.6,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-reflected-xss"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/cisco-spa100-series-ata-information-disclosure-via-web-management-interface-30650"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2019.3878/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"date": "2019-10-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"date": "2019-10-16T19:15:11.847000",
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"date": "2019-10-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-36893"
},
{
"date": "2019-10-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-011136"
},
{
"date": "2019-10-21T17:01:59.493000",
"db": "NVD",
"id": "CVE-2019-12708"
},
{
"date": "2019-10-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco SPA100 Series Analog Telephone Adapters Vulnerable to information disclosure",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-011136"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1091"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…