var-201910-0345
Vulnerability from variot
A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to access sensitive information on an affected device. The vulnerability is due to unsafe handling of user credentials. An attacker could exploit this vulnerability by viewing portions of the web-based management interface of an affected device. A successful exploit could allow the attacker to access administrative credentials and potentially gain elevated privileges by reusing stolen credentials on the affected device
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-0345", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "spa122", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "1.4.1" }, { "model": "spa112", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "1.4.1" }, { "model": "spa122", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "1.4.1" }, { "model": "spa112", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "1.4.1" }, { "model": "spa 112", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "spa 122", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "spa100 series sr3", "scope": "lte", "trust": 0.6, "vendor": "cisco", "version": "\u003c=1.4.1" }, { "model": "spa112", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": null }, { "model": "spa122", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:spa112:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:spa122_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:spa122:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-12708" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Andrew Orr and Alex Weber of Tenable Inc. .", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1091" } ], "trust": 0.6 }, "cve": "CVE-2019-12708", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2019-12708", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CNVD-2019-36893", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "ykramarz@cisco.com", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-12708", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-12708", "trust": 1.8, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2019-12708", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2019-36893", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201910-1091", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to access sensitive information on an affected device. The vulnerability is due to unsafe handling of user credentials. An attacker could exploit this vulnerability by viewing portions of the web-based management interface of an affected device. A successful exploit could allow the attacker to access administrative credentials and potentially gain elevated privileges by reusing stolen credentials on the affected device", "sources": [ { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "CNVD", "id": "CNVD-2019-36893" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-12708", "trust": 3.0 }, { "db": "TENABLE", "id": "TRA-2019-44", "trust": 1.6 }, { "db": "JVNDB", "id": "JVNDB-2019-011136", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2019-36893", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.3878", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201910-1091", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "id": "VAR-201910-0345", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" } ] }, "last_update_date": "2023-12-18T11:59:21.576000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20191016-spa-credentials", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-credentials" }, { "title": "Patch for Cisco SPA100 Information Disclosure Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/186441" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-credentials" }, { "trust": 1.6, "url": "https://www.tenable.com/security/research/tra-2019-44" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-12708" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-12708" }, { "trust": 0.6, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-ui-disclosure" }, { "trust": 0.6, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-webui-dos" }, { "trust": 0.6, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-running-config" }, { "trust": 0.6, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-rce" }, { "trust": 0.6, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20191016-spa-reflected-xss" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/cisco-spa100-series-ata-information-disclosure-via-web-management-interface-30650" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3878/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-36893" }, { "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "db": "NVD", "id": "CVE-2019-12708" }, { "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2019-36893" }, { "date": "2019-10-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "date": "2019-10-16T19:15:11.847000", "db": "NVD", "id": "CVE-2019-12708" }, { "date": "2019-10-16T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-24T00:00:00", "db": "CNVD", "id": "CNVD-2019-36893" }, { "date": "2019-10-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-011136" }, { "date": "2019-10-21T17:01:59.493000", "db": "NVD", "id": "CVE-2019-12708" }, { "date": "2019-10-22T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-1091" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1091" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco SPA100 Series Analog Telephone Adapters Vulnerable to information disclosure", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-011136" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1091" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.