VAR-201910-0808
Vulnerability from variot - Updated: 2023-12-18 12:50An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.). Mitsubishi Electric ME-RTU Device and INEA ME-RTU A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Inea ME-RTU is an intelligent communication gateway product from Inea Company of Slovenia. The vulnerability originates from a program with an undocumented account (using hard-coded credentials). An attacker could exploit this vulnerability to Elevated to root
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201910-0808",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "me-rtu",
"scope": "lte",
"trust": 1.0,
"vendor": "inea",
"version": "3.0"
},
{
"model": "smartrtu",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "2.02"
},
{
"model": "me-rtu",
"scope": null,
"trust": 0.8,
"vendor": "inea d o o",
"version": null
},
{
"model": "smartrtu",
"scope": null,
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": null
},
{
"model": "electric mitsubishi electric smartrtu",
"scope": "lte",
"trust": 0.6,
"vendor": "mitsubishi",
"version": "\u003c=2.02"
},
{
"model": "me-rtu",
"scope": "lte",
"trust": 0.6,
"vendor": "inea",
"version": "\u003c=3.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "smartrtu",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "me rtu",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.02",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-14930"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mark Cross (@xerubus) reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
],
"trust": 0.6
},
"cve": "CVE-2019-14930",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-14930",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-47031",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-14930",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-14930",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-47031",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201910-1541",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48",
"trust": 0.2,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.). Mitsubishi Electric ME-RTU Device and INEA ME-RTU A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Inea ME-RTU is an intelligent communication gateway product from Inea Company of Slovenia. The vulnerability originates from a program with an undocumented account (using hard-coded credentials). An attacker could exploit this vulnerability to Elevated to root",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-14930",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-252-03",
"trust": 1.4
},
{
"db": "CNVD",
"id": "CNVD-2019-47031",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1541",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU93054759",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2021.3043",
"trust": 0.6
},
{
"db": "IVD",
"id": "5D9E3906-45AF-46CF-8EB3-1DB53E8E8B48",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"id": "VAR-201910-0808",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
}
],
"trust": 1.59411765
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
}
]
},
"last_update_date": "2023-12-18T12:50:01.300000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ME\u00a0RTU Mitsubishi Electric MITSUBISHI\u00a0ELECTRIC\u00a0AUTOMATION",
"trust": 0.8,
"url": "http://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://www.mogozobo.com/?p=3593"
},
{
"trust": 1.6,
"url": "https://www.mogozobo.com/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-14930"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-03"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu93054759/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.3043"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-26T00:00:00",
"db": "IVD",
"id": "5d9e3906-45af-46cf-8eb3-1db53e8e8b48"
},
{
"date": "2019-12-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"date": "2019-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"date": "2019-10-28T13:15:10.993000",
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"date": "2019-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-47031"
},
{
"date": "2021-09-14T05:56:00",
"db": "JVNDB",
"id": "JVNDB-2019-011333"
},
{
"date": "2019-10-30T17:50:31.817000",
"db": "NVD",
"id": "CVE-2019-14930"
},
{
"date": "2021-09-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mitsubishi\u00a0Electric\u00a0ME-RTU\u00a0 Device and \u00a0INEA\u00a0ME-RTU\u00a0 Vulnerability in using hard-coded credentials on devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-011333"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201910-1541"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.