A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. SPPA-T3000 Application Server Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. Application Server is one of the application servers that provides the main system services, including access control, data distribution to thin clients, and archiving.

There is a security vulnerability in the Siemens SPPA-T3000 Application Server

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201912-1280",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sppa-t3000 application server",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sppa-t3000 application server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "r8.2"
      },
      {
        "model": "sppa-t3000 application server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "r8.2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sppa t3000 application server",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sppa-t3000_application_server:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "r8.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      }
    ]
  },
  "cve": "CVE-2019-18314",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2019-18314",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-45374",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-18314",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2019-18314",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-45374",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201912-629",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5",
            "trust": 0.2,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. SPPA-T3000 Application Server Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. Application Server is one of the application servers that provides the main system services, including access control, data distribution to thin clients, and archiving. \n\nThere is a security vulnerability in the Siemens SPPA-T3000 Application Server",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-18314",
        "trust": 3.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-451445",
        "trust": 2.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-351-02",
        "trust": 1.4
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.4705",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "FF9F3EB8-3DCA-4195-AFC6-D691F20746A5",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "id": "VAR-201912-1280",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      }
    ],
    "trust": 1.4666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:59:06.579000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-451445",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
      },
      {
        "title": "Patch for Siemens SPPA-T3000 Application Server Improper Authentication Vulnerability (CNVD-2019-45374)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/194231"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-351-02"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18314"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18314"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.4705/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-12-16T00:00:00",
        "db": "IVD",
        "id": "ff9f3eb8-3dca-4195-afc6-d691f20746a5"
      },
      {
        "date": "2019-12-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "date": "2019-12-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "date": "2019-12-12T19:15:18.157000",
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "date": "2019-12-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-12-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-45374"
      },
      {
        "date": "2019-12-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      },
      {
        "date": "2022-03-04T20:09:30.263000",
        "db": "NVD",
        "id": "CVE-2019-18314"
      },
      {
        "date": "2022-02-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SPPA-T3000 Application Server Authentication vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013101"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201912-629"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.