var-201912-1828
Vulnerability from variot
Insufficient access control in hardware abstraction driver for MEInfo software for Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45, 13.0.0, 14.0.10; TXEInfo software for Intel(R) TXE before versions 3.1.70 and 4.0.20; INTEL-SA-00086 Detection Tool version 1.2.7.0 or before; INTEL-SA-00125 Detection Tool version 1.0.45.0 or before may allow an authenticated user to potentially enable escalation of privilege via local access. plural Intel There are unspecified vulnerabilities in the product.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Intel Converged Security and Management Engine (CSME) and others are products of Intel Corporation of the United States. Intel Converged Security and Management Engine is a security management engine. Intel TXE is a trusted execution engine with hardware authentication function used in CPU (Central Processing Unit). INTEL-SA-00086 Detection Tool is a detection tool for detecting INTEL-SA-00086 security issues. A security vulnerability exists in several Intel products. The vulnerability is caused by the program's insufficient access control. A local attacker could exploit this vulnerability to elevate privileges. The following products and versions are affected: Intel CSME before 11.8.70, before 11.11.70, before 11.22.70, before 12.0.45, before 13.0.0, before 14.0.10; Intel TXE 3.1.70 Previous versions, versions before 4.0.20; INTEL-SA-00086 Detection Tool 1.2.7.0 and earlier versions; INTEL-SA-00125 Detection Tool 1.0.45.0 and earlier versions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201912-1828", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "11.11.70" }, { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "11.22.70" }, { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "11.8.70" }, { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "12.0.45" }, { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "13.0.0" }, { "model": "converged security management engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "14.0.10" }, { "model": "trusted execution engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "3.1.70" }, { "model": "trusted execution engine", "scope": "lt", "trust": 1.8, "vendor": "intel", "version": "4.0.20" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "11.10" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "13.0" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "11.20" }, { "model": "intel-sa-00125 detection tool", "scope": "lte", "trust": 1.0, "vendor": "intel", "version": "1.0.45.0" }, { "model": "trusted execution engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "3.0" }, { "model": "sa-00086 detection tool", "scope": "lte", "trust": 1.0, "vendor": "intel", "version": "1.2.7.0" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "14.0.0" }, { "model": "trusted execution engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "4.0" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "11.0" }, { "model": "converged security management engine", "scope": "gte", "trust": 1.0, "vendor": "intel", "version": "12.0" }, { "model": "intel-sa-00086 detection tool", "scope": null, "trust": 0.8, "vendor": "intel", "version": null }, { "model": "intel-sa-00125 detection tool", "scope": null, "trust": 0.8, "vendor": "intel", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:intel:intel-sa-00125_detection_tool:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.0.45.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:intel:sa-00086_detection_tool:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.2.7.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "11.8.70", "versionStartIncluding": "11.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "11.11.70", "versionStartIncluding": "11.10", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "11.22.70", "versionStartIncluding": "11.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "12.0.45", "versionStartIncluding": "12.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.0.0", "versionStartIncluding": "13.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.0.10", "versionStartIncluding": "14.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1.70", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0.20", "versionStartIncluding": "4.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-11147" } ] }, "cve": "CVE-2019-11147", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 4.6, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2019-11147", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "VHN-142764", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-11147", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-11147", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201911-655", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-142764", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-142764" }, { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" }, { "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Insufficient access control in hardware abstraction driver for MEInfo software for Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45, 13.0.0, 14.0.10; TXEInfo software for Intel(R) TXE before versions 3.1.70 and 4.0.20; INTEL-SA-00086 Detection Tool version 1.2.7.0 or before; INTEL-SA-00125 Detection Tool version 1.0.45.0 or before may allow an authenticated user to potentially enable escalation of privilege via local access. plural Intel There are unspecified vulnerabilities in the product.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Intel Converged Security and Management Engine (CSME) and others are products of Intel Corporation of the United States. Intel Converged Security and Management Engine is a security management engine. Intel TXE is a trusted execution engine with hardware authentication function used in CPU (Central Processing Unit). INTEL-SA-00086 Detection Tool is a detection tool for detecting INTEL-SA-00086 security issues. A security vulnerability exists in several Intel products. The vulnerability is caused by the program\u0027s insufficient access control. A local attacker could exploit this vulnerability to elevate privileges. The following products and versions are affected: Intel CSME before 11.8.70, before 11.11.70, before 11.22.70, before 12.0.45, before 13.0.0, before 14.0.10; Intel TXE 3.1.70 Previous versions, versions before 4.0.20; INTEL-SA-00086 Detection Tool 1.2.7.0 and earlier versions; INTEL-SA-00125 Detection Tool 1.0.45.0 and earlier versions", "sources": [ { "db": "NVD", "id": "CVE-2019-11147" }, { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "VULHUB", "id": "VHN-142764" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-11147", "trust": 2.5 }, { "db": "JVN", "id": "JVNVU90354904", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-013695", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201911-655", "trust": 0.7 }, { "db": "LENOVO", "id": "LEN-27716", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.2344", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2020-18612", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-142764", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-142764" }, { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" }, { "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "id": "VAR-201912-1828", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-142764" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T11:15:13.364000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "INTEL-SA-00241", "trust": 0.8, "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html" }, { "title": "Multiple Intel Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=103867" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "CWE-Other", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-11147" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-11147" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90354904/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/intel-csme-amt-dal-sps-txe-multiple-vulnerabilities-31014" }, { "trust": 0.6, "url": "https://support.lenovo.com/us/en/product_security/len-27716" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2344/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-142764" }, { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" }, { "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-142764" }, { "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "db": "NVD", "id": "CVE-2019-11147" }, { "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-12-18T00:00:00", "db": "VULHUB", "id": "VHN-142764" }, { "date": "2020-01-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "date": "2019-12-18T22:15:13.457000", "db": "NVD", "id": "CVE-2019-11147" }, { "date": "2019-11-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-01-02T00:00:00", "db": "VULHUB", "id": "VHN-142764" }, { "date": "2020-01-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-013695" }, { "date": "2020-01-02T19:03:35.980000", "db": "NVD", "id": "CVE-2019-11147" }, { "date": "2020-07-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201911-655" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201911-655" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Intel Product vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-013695" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-201911-655" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.