var-202009-1544
Vulnerability from variot
Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. CodeMeter Contains a cryptographic vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SIMATIC WinCC OA (Open Architecture) is a set of SCADA system of Siemens (Siemens), Germany, and it is also an integral part of HMI series. The system is mainly suitable for industries such as rail transit, building automation and public power supply. Information Server is used to report and visualize the process data stored in the Process Historian. SINEC INS is a web-based application that combines various network services in one tool. SPPA-S2000 simulates the automation component (S7) of the nuclear DCS system SPPA-T2000. SPPA-S3000 simulates the automation components of DCS system SPPA-T3000. SPPA-T3000 is a distributed control system, mainly used in fossil and large renewable energy power plants.
Many Siemens products have security vulnerabilities. Attackers can use the vulnerability to communicate with CodeMeter API remotely
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202009-1544", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "codemeter", "scope": "lt", "trust": 1.0, "vendor": "wibu", "version": "6.90" }, { "model": "codemeter", "scope": null, "trust": 0.8, "vendor": "wibu", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": "6.90" }, { "model": "information server sp1", "scope": "lte", "trust": 0.6, "vendor": "siemens", "version": "\u003c=2019" }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.17" }, { "model": "sinec ins", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sppa-s2000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.04" }, { "model": "sppa-s2000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.06" }, { "model": "sppa-t3000 r8.2 sp2", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sppa-s3000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.05" }, { "model": "sppa-s3000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.04" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.90", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14517" } ] }, "cve": "CVE-2020-14517", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-14517", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.7, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2020-51242", "impactScore": 9.5, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-14517", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14517", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2020-51242", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202009-489", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. CodeMeter Contains a cryptographic vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SIMATIC WinCC OA (Open Architecture) is a set of SCADA system of Siemens (Siemens), Germany, and it is also an integral part of HMI series. The system is mainly suitable for industries such as rail transit, building automation and public power supply. Information Server is used to report and visualize the process data stored in the Process Historian. SINEC INS is a web-based application that combines various network services in one tool. SPPA-S2000 simulates the automation component (S7) of the nuclear DCS system SPPA-T2000. SPPA-S3000 simulates the automation components of DCS system SPPA-T3000. SPPA-T3000 is a distributed control system, mainly used in fossil and large renewable energy power plants. \n\r\n\r\nMany Siemens products have security vulnerabilities. Attackers can use the vulnerability to communicate with CodeMeter API remotely", "sources": [ { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNVD", "id": "CNVD-2020-51242" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14517", "trust": 3.8 }, { "db": "ICS CERT", "id": "ICSA-20-203-01", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU90770748", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU94568336", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-011222", "trust": 0.8 }, { "db": "SIEMENS", "id": "SSA-455843", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2020-51242", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076.2", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076.3", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022021806", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202009-489", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "id": "VAR-202009-1544", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" } ], "trust": 1.3399059128571427 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" } ] }, "last_update_date": "2023-12-18T10:57:30.677000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "CodeMeter", "trust": 0.8, "url": "https://www.wibu.com/products/codemeter.html" }, { "title": "Patch for Vulnerabilities in insufficient encryption strength of many Siemens products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/233344" }, { "title": "ARC and MATIO Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=127910" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-327", "trust": 1.0 }, { "problemtype": "Inadequate encryption strength (CWE-326) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14517" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu94568336/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90770748/" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-six-vulnerabilities-via-wibu-systems-codemeter-runtime-33282" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022021806" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076.2/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076.3/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-09-10T00:00:00", "db": "CNVD", "id": "CNVD-2020-51242" }, { "date": "2021-03-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "date": "2020-09-16T20:15:13.647000", "db": "NVD", "id": "CVE-2020-14517" }, { "date": "2020-09-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-09-10T00:00:00", "db": "CNVD", "id": "CNVD-2020-51242" }, { "date": "2022-03-15T05:10:00", "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "date": "2021-11-04T18:15:08.017000", "db": "NVD", "id": "CVE-2020-14517" }, { "date": "2022-02-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202009-489" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "CodeMeter\u00a0 Vulnerability in cryptography", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-011222" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202009-489" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.