var-202010-1047
Vulnerability from variot
A vulnerability in the host input API daemon of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper certificate validation. An attacker could exploit this vulnerability by sending a crafted data stream to the host input daemon of the affected device. A successful exploit could allow the attacker to cause the host input daemon to restart. The attacker could use repeated attacks to cause the daemon to continuously reload, creating a DoS condition for the API
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-1047", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "firepower management center", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "6.6.1" }, { "model": "cisco firepower management center", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.6.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-3557" } ] }, "cve": "CVE-2020-3557", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2020-3557", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-181682", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "Low", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2020-3557", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-3557", "trust": 1.8, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2020-3557", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202010-1165", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-181682", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2020-3557", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-181682" }, { "db": "VULMON", "id": "CVE-2020-3557" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the host input API daemon of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper certificate validation. An attacker could exploit this vulnerability by sending a crafted data stream to the host input daemon of the affected device. A successful exploit could allow the attacker to cause the host input daemon to restart. The attacker could use repeated attacks to cause the daemon to continuously reload, creating a DoS condition for the API", "sources": [ { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "VULHUB", "id": "VHN-181682" }, { "db": "VULMON", "id": "CVE-2020-3557" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-3557", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2020-012618", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-1165", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.3637", "trust": 0.6 }, { "db": "NSFOCUS", "id": "50162", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-181682", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2020-3557", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181682" }, { "db": "VULMON", "id": "CVE-2020-3557" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "id": "VAR-202010-1047", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-181682" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T12:16:48.823000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-fmc-dos-3WymYWKh", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-fmc-dos-3wymywkh" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012618" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-295", "trust": 1.1 }, { "problemtype": "Bad certificate verification (CWE-295) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-181682" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-fmc-dos-3wymywkh" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-3557" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3637/" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/50162" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/295.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULHUB", "id": "VHN-181682" }, { "db": "VULMON", "id": "CVE-2020-3557" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-181682" }, { "db": "VULMON", "id": "CVE-2020-3557" }, { "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "db": "NVD", "id": "CVE-2020-3557" }, { "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-21T00:00:00", "db": "VULHUB", "id": "VHN-181682" }, { "date": "2020-10-21T00:00:00", "db": "VULMON", "id": "CVE-2020-3557" }, { "date": "2021-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "date": "2020-10-21T19:15:17.607000", "db": "NVD", "id": "CVE-2020-3557" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-28T00:00:00", "db": "VULHUB", "id": "VHN-181682" }, { "date": "2020-10-28T00:00:00", "db": "VULMON", "id": "CVE-2020-3557" }, { "date": "2021-05-17T09:06:00", "db": "JVNDB", "id": "JVNDB-2020-012618" }, { "date": "2023-11-07T03:22:54.610000", "db": "NVD", "id": "CVE-2020-3557" }, { "date": "2020-11-04T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-1165" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-1165" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco\u00a0Firepower\u00a0Management\u00a0Center\u00a0 Certificate validation vulnerabilities in software", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012618" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "trust management problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-1165" } ], "trust": 0.6 } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.