VAR-202103-0433
Vulnerability from variot - Updated: 2023-12-18 13:47Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service condition. The FAULT LED will flash RED and communications may be lost. Recovery from denial-of-service condition requires the fault to be cleared by the user. Rockwell Automation Provided by the company MicroLogix 1400 Received Modbus Buffer overflow vulnerability due to packet processing (CWE-120) Exists. As a result, a buffer overflow occurs, and FAULT LED Flashes red and communication may be lost.Service operation obstruction by a remote third party (DoS) You may be attacked. Micrologix 1400 is a programmable logic controller introduced by Rockwell Automation
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202103-0433",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "micrologix 1400",
"scope": "lte",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "21.6"
},
{
"model": "micrologix",
"scope": "eq",
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "micrologix",
"scope": "lte",
"trust": 0.8,
"vendor": "rockwell automation",
"version": "1400 all series version 21.6 and earlier"
},
{
"model": "automation micrologix",
"scope": "eq",
"trust": 0.6,
"vendor": "rockwell",
"version": "1400\u003c=21.6"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "21.6",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22659"
}
]
},
"cve": "CVE-2021-22659",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-34433",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2021-22659",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"exploitabilityScore": 3.9,
"impactScore": 4.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "IPA",
"availabilityImpact": "High",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2021-001018",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22659",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "IPA",
"id": "JVNDB-2021-001018",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-34433",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-213",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-22659",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service condition. The FAULT LED will flash RED and communications may be lost. Recovery from denial-of-service condition requires the fault to be cleared by the user. Rockwell Automation Provided by the company MicroLogix 1400 Received Modbus Buffer overflow vulnerability due to packet processing (CWE-120) Exists. As a result, a buffer overflow occurs, and FAULT LED Flashes red and communication may be lost.Service operation obstruction by a remote third party (DoS) You may be attacked. Micrologix 1400 is a programmable logic controller introduced by Rockwell Automation",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "VULMON",
"id": "CVE-2021-22659"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22659",
"trust": 3.1
},
{
"db": "ICS CERT",
"id": "ICSA-21-033-01",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU93359735",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-34433",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0383",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-22659",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"id": "VAR-202103-0433",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
}
],
"trust": 1.4076923
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
}
]
},
"last_update_date": "2023-12-18T13:47:12.176000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Rockwell\u00a0Automation\u00a0Security\u00a0Advisory\u00a0PN1545\u00a0( Login required )",
"trust": 0.8,
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1"
},
{
"title": "Patch for Rockwell Automation MicroLogix 1400 buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/264596"
},
{
"title": "Allen-Bradley Flex IO Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140420"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [IPA Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-01"
},
{
"trust": 1.7,
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1129877/loc/en_us#__highlight"
},
{
"trust": 0.8,
"url": "http://jvn.jp/cert/jvnvu93359735"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0383/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"date": "2021-03-25T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"date": "2021-02-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"date": "2021-03-25T16:15:14.040000",
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"date": "2021-02-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-34433"
},
{
"date": "2021-03-31T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22659"
},
{
"date": "2021-03-25T07:28:00",
"db": "JVNDB",
"id": "JVNDB-2021-001018"
},
{
"date": "2021-03-31T15:56:20.927000",
"db": "NVD",
"id": "CVE-2021-22659"
},
{
"date": "2021-04-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rockwell\u00a0Automation\u00a0 Made \u00a0MicroLogix\u00a01400\u00a0 Buffer overflow vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-001018"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-213"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.