VAR-202104-1582
Vulnerability from variot - Updated: 2023-12-18 12:26A potential security vulnerability has been identified in HPE Superdome Flex server. A denial of service attack can be remotely exploited leaving hung connections to the BMC web interface. The monarch BMC must be rebooted to recover from this situation. Other BMC management is not impacted. HPE has made the following software update to resolve the vulnerability in HPE Superdome Flex Server: Superdome Flex Server Firmware 3.30.142 or later
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202104-1582",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "superdome flex server",
"scope": "lt",
"trust": 1.0,
"vendor": "hpe",
"version": "3.30.142"
},
{
"model": "\u65e5\u7acb\u9ad8\u4fe1\u983c\u30b5\u30fc\u30d0 rv3000",
"scope": null,
"trust": 0.8,
"vendor": "\u65e5\u7acb",
"version": null
},
{
"model": "hpe superdome flex server",
"scope": null,
"trust": 0.8,
"vendor": "\u30d2\u30e5\u30fc\u30ec\u30c3\u30c8 \u30d1\u30c3\u30ab\u30fc\u30c9 \u30a8\u30f3\u30bf\u30fc\u30d7\u30e9\u30a4\u30ba",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hpe:superdome_flex_server_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.30.142",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hpe:superdome_flex_server:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-26581"
}
]
},
"cve": "CVE-2021-26581",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2021-26581",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2021-26581",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-26581",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202104-061",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2021-26581",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A potential security vulnerability has been identified in HPE Superdome Flex server. A denial of service attack can be remotely exploited leaving hung connections to the BMC web interface. The monarch BMC must be rebooted to recover from this situation. Other BMC management is not impacted. HPE has made the following software update to resolve the vulnerability in HPE Superdome Flex Server: Superdome Flex Server Firmware 3.30.142 or later",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "VULMON",
"id": "CVE-2021-26581"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-26581",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-26581",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"id": "VAR-202104-1582",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T12:26:53.670000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "hpesbhf04102en_us Hitachi Server / Client Product Security Information",
"trust": 0.8,
"url": "https://support.hpe.com/hpesc/public/docdisplay?doclocale=en_us\u0026docid=emr_na-hpesbhf04102en_us"
},
{
"title": "HPE Superdome Flex serve Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=146467"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbhf04102en_us"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-26581"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/199289"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-01T00:00:00",
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"date": "2022-06-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"date": "2021-04-01T19:15:13.887000",
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"date": "2021-04-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-06T00:00:00",
"db": "VULMON",
"id": "CVE-2021-26581"
},
{
"date": "2022-06-28T07:13:00",
"db": "JVNDB",
"id": "JVNDB-2021-010259"
},
{
"date": "2021-04-06T18:50:41.680000",
"db": "NVD",
"id": "CVE-2021-26581"
},
{
"date": "2021-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "HPE\u00a0Superdome\u00a0Flex\u00a0server\u00a0 Vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010259"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-061"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…