var-202108-0403
Vulnerability from variot
Dell PowerScale OneFS 9.1.0.x contains an improper privilege management vulnerability. It may allow an authenticated user with ISI_PRIV_LOGIN_SSH and/or ISI_PRIV_LOGIN_CONSOLE to elevate privilege. Dell PowerScale OneFS Exists in a permission management vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202108-0403", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "powerscale onefs", "scope": "eq", "trust": 1.0, "vendor": "dell", "version": "9.0.0.0" }, { "model": "powerscale onefs", "scope": "eq", "trust": 1.0, "vendor": "dell", "version": "9.1.0.0" }, { "model": "emc powerscale onefs", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null }, { "model": "emc powerscale onefs", "scope": "eq", "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:dell:powerscale_onefs:9.0.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:dell:powerscale_onefs:9.1.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-21567" } ] }, "cve": "CVE-2021-21567", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 4.6, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-21567", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "VHN-379971", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-010731", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-21567", "trust": 1.8, "value": "HIGH" }, { "author": "security_alert@emc.com", "id": "CVE-2021-21567", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202108-1007", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-379971", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-21567", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-379971" }, { "db": "VULMON", "id": "CVE-2021-21567" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Dell PowerScale OneFS 9.1.0.x contains an improper privilege management vulnerability. It may allow an authenticated user with ISI_PRIV_LOGIN_SSH and/or ISI_PRIV_LOGIN_CONSOLE to elevate privilege. Dell PowerScale OneFS Exists in a permission management vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "VULHUB", "id": "VHN-379971" }, { "db": "VULMON", "id": "CVE-2021-21567" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-21567", "trust": 3.4 }, { "db": "JVNDB", "id": "JVNDB-2021-010731", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202108-1007", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-379971", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2021-21567", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-379971" }, { "db": "VULMON", "id": "CVE-2021-21567" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "id": "VAR-202108-0403", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-379971" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T13:42:30.630000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "DSA-2021-123", "trust": 0.8, "url": "https://www.dell.com/support/kbdoc/ja-jp/000189495/dsa-2021-123-dell-powerscale-onefs-security-update-for-multiple-vulnerabilities" }, { "title": "Dell Technologies Dell PowerScale OneFS Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159390" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-269", "trust": 1.1 }, { "problemtype": "Improper authority management (CWE-269) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-379971" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://www.dell.com/support/kbdoc/000189495" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21567" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/732.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULHUB", "id": "VHN-379971" }, { "db": "VULMON", "id": "CVE-2021-21567" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-379971" }, { "db": "VULMON", "id": "CVE-2021-21567" }, { "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "db": "NVD", "id": "CVE-2021-21567" }, { "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-10T00:00:00", "db": "VULHUB", "id": "VHN-379971" }, { "date": "2021-08-10T00:00:00", "db": "VULMON", "id": "CVE-2021-21567" }, { "date": "2022-07-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "date": "2021-08-10T19:15:07.193000", "db": "NVD", "id": "CVE-2021-21567" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-26T00:00:00", "db": "VULHUB", "id": "VHN-379971" }, { "date": "2021-08-17T00:00:00", "db": "VULMON", "id": "CVE-2021-21567" }, { "date": "2022-07-07T04:43:00", "db": "JVNDB", "id": "JVNDB-2021-010731" }, { "date": "2022-04-26T15:32:52.730000", "db": "NVD", "id": "CVE-2021-21567" }, { "date": "2022-04-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-1007" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-1007" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Dell\u00a0PowerScale\u00a0OneFS\u00a0 Vulnerability in privilege management in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010731" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-1007" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.