var-202204-1936
Vulnerability from variot
A vulnerability in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to bypass security protections and upload malicious files to the affected system. This vulnerability is due to improper validation of files uploaded to the web management interface of Cisco FMC Software. An attacker could exploit this vulnerability by uploading a maliciously crafted file to a device running affected software. A successful exploit could allow the attacker to store malicious files on the device, which they could access later to conduct additional attacks, including executing arbitrary code on the affected device with root privileges. (DoS) It may be in a state. Cisco Firepower Management Center (FMC) is a new generation of firewall management center software from Cisco. There are no workarounds that address this vulnerability. This advisory is available at the following link:tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-security-bypass-JhOd29Gg
This advisory is part of the April 2022 release of the Cisco ASA, FTD, and FMC Security Advisory Bundled publication. For a complete list of the advisories and links to them, see Cisco Event Response: April 2022 Cisco ASA, FMC, and FTD Software Security Advisory Bundled Publication
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202204-1936", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "firepower management center", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "6.7.0" }, { "model": "firepower management center", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.1.0" }, { "model": "firepower management center", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.0.2" }, { "model": "firepower management center", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.1.0.1" }, { "model": "firepower management center", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "6.4.0.15" }, { "model": "firepower management center", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "6.5.0" }, { "model": "firepower management center", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "6.6.5.2" }, { "model": "cisco firepower management center", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba", "version": null }, { "model": "cisco firepower management center", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0.2", "versionStartIncluding": "6.7.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.1.0.1", "versionStartIncluding": "7.1.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.6.5.2", "versionStartIncluding": "6.5.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4.0.15", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-20743" } ] }, "cve": "CVE-2022-20743", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 9.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2022-20743", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "VHN-405296", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "ykramarz@cisco.com", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-20743", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-20743", "trust": 1.8, "value": "HIGH" }, { "author": "ykramarz@cisco.com", "id": "CVE-2022-20743", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202204-4509", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-405296", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-405296" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to bypass security protections and upload malicious files to the affected system. This vulnerability is due to improper validation of files uploaded to the web management interface of Cisco FMC Software. An attacker could exploit this vulnerability by uploading a maliciously crafted file to a device running affected software. A successful exploit could allow the attacker to store malicious files on the device, which they could access later to conduct additional attacks, including executing arbitrary code on the affected device with root privileges. (DoS) It may be in a state. Cisco Firepower Management Center (FMC) is a new generation of firewall management center software from Cisco. There are no workarounds that address this vulnerability. \nThis advisory is available at the following link:tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-security-bypass-JhOd29Gg\n\nThis advisory is part of the April 2022 release of the Cisco ASA, FTD, and FMC Security Advisory Bundled publication. For a complete list of the advisories and links to them, see Cisco Event Response: April 2022 Cisco ASA, FMC, and FTD Software Security Advisory Bundled Publication", "sources": [ { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "VULHUB", "id": "VHN-405296" }, { "db": "VULMON", "id": "CVE-2022-20743" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-20743", "trust": 3.4 }, { "db": "JVNDB", "id": "JVNDB-2022-010238", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2022042809", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.1905", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202204-4509", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2022-43399", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-405296", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2022-20743", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-405296" }, { "db": "VULMON", "id": "CVE-2022-20743" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "id": "VAR-202204-1936", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-405296" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T12:26:14.700000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-fmc-security-bypass-JhOd29Gg", "trust": 0.8, "url": "https://sec.cloudapps.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-fmc-security-bypass-jhod29gg" }, { "title": "Cisco Firepower Management Center Fixes for code issue vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=191926" }, { "title": "Cisco: Cisco Firepower Management Center File Upload Security Bypass Vulnerability", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=cisco_security_advisories_and_alerts_ciscoproducts\u0026qid=cisco-sa-fmc-security-bypass-jhod29gg" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-20743" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-434", "trust": 1.1 }, { "problemtype": "Unlimited uploads of dangerous types of files (CWE-434) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-405296" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-fmc-security-bypass-jhod29gg" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-20743" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022042809" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.1905" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-20743/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-405296" }, { "db": "VULMON", "id": "CVE-2022-20743" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-405296" }, { "db": "VULMON", "id": "CVE-2022-20743" }, { "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "db": "NVD", "id": "CVE-2022-20743" }, { "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-03T00:00:00", "db": "VULHUB", "id": "VHN-405296" }, { "date": "2023-08-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "date": "2022-05-03T04:15:09.377000", "db": "NVD", "id": "CVE-2022-20743" }, { "date": "2022-04-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-09T00:00:00", "db": "VULHUB", "id": "VHN-405296" }, { "date": "2023-08-14T05:30:00", "db": "JVNDB", "id": "JVNDB-2022-010238" }, { "date": "2023-11-07T03:42:49.077000", "db": "NVD", "id": "CVE-2022-20743" }, { "date": "2022-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-4509" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-4509" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco\u00a0Firepower\u00a0Management\u00a0Center\u00a0 Unrestricted Upload of Dangerous File Types Vulnerability in Software", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-010238" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-4509" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.