VAR-202302-0671

Vulnerability from variot - Updated: 2023-12-18 12:33

LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol. ls-electric of xbc-dn32u There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. LS ELECTRIC XBC-DN32U is a PLC programmable logic controller produced by LS ELECTRIC in Korea

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202302-0671",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "xbc-dn32u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ls electric",
        "version": "01.80"
      },
      {
        "model": "xbc-dn32u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "ls electric",
        "version": "xbc-dn32u  firmware  01.80"
      },
      {
        "model": "xbc-dn32u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "ls electric",
        "version": null
      },
      {
        "model": "xbc-dn32u",
        "scope": null,
        "trust": 0.8,
        "vendor": "ls electric",
        "version": null
      },
      {
        "model": "electric xbc-dn32u",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "ls",
        "version": "01.80"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:ls-electric:xbc-dn32u_firmware:01.80:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:ls-electric:xbc-dn32u:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      }
    ]
  },
  "cve": "CVE-2023-22807",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-21677",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-22807",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-22807",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "ics-cert@hq.dhs.gov",
            "id": "CVE-2023-22807",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-21677",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202302-1269",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol.  An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol. ls-electric of xbc-dn32u There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. LS ELECTRIC XBC-DN32U is a PLC programmable logic controller produced by LS ELECTRIC in Korea",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-22807"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-22807",
        "trust": 3.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-040-02",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU97136726",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-22807",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-22807"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "id": "VAR-202302-0671",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:33:59.611000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu97136726/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-22807"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-22807/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-22807"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-22807"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "date": "2023-10-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "date": "2023-02-15T18:15:12.087000",
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "date": "2023-02-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-21677"
      },
      {
        "date": "2023-10-26T04:54:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      },
      {
        "date": "2023-11-07T04:07:25.663000",
        "db": "NVD",
        "id": "CVE-2023-22807"
      },
      {
        "date": "2023-02-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ls-electric\u00a0 of \u00a0xbc-dn32u\u00a0 Firmware vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-004158"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1269"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…