Insufficient control flow management in the Intel(R) Battery Life Diagnostic Tool software before version 2.2.0 may allow an authenticated user to potentially enable escalation of privilege via local access. Intel's Battery Life Diagnostic Tool Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202302-1221",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "battery life diagnostic tool",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "intel",
        "version": "2.2.0"
      },
      {
        "model": "battery life diagnostic tool",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30a4\u30f3\u30c6\u30eb",
        "version": "2.2.0"
      },
      {
        "model": "battery life diagnostic tool",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30a4\u30f3\u30c6\u30eb",
        "version": null
      },
      {
        "model": "battery life diagnostic tool",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30a4\u30f3\u30c6\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:intel:battery_life_diagnostic_tool:2.2.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      }
    ]
  },
  "cve": "CVE-2022-36278",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "secure@intel.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.5,
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36278",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-36278",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "secure@intel.com",
            "id": "CVE-2022-36278",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202302-1330",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Insufficient control flow management in the Intel(R) Battery Life Diagnostic Tool software before version 2.2.0 may allow an authenticated user to potentially enable escalation of privilege via local access. Intel\u0027s Battery Life Diagnostic Tool Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36278"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36278",
        "trust": 3.4
      },
      {
        "db": "JVN",
        "id": "JVNVU91223897",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2023.0897",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-432395",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36278",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "id": "VAR-202302-1221",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T11:19:14.221000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Intel Battery Life Diagnostic Tool Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=225843"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2022-36278 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "others (CWE-Other) [NVD evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-670",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00726.html"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36278"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91223897/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2023.0897"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36278/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2022-36278"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-02-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "date": "2023-02-16T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "date": "2023-10-30T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "date": "2023-02-16T20:15:14.793000",
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "date": "2023-02-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-432395"
      },
      {
        "date": "2023-02-17T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-36278"
      },
      {
        "date": "2023-10-30T05:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      },
      {
        "date": "2023-08-08T14:21:49.707000",
        "db": "NVD",
        "id": "CVE-2022-36278"
      },
      {
        "date": "2023-03-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Intel\u0027s \u00a0Battery\u00a0Life\u00a0Diagnostic\u00a0Tool\u00a0 Vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-019924"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-1330"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.