VAR-202303-0898
Vulnerability from variot - Updated: 2023-12-18 11:44A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334). Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. Siemens Tecnomatix Plant Simulation is an industrial control equipment of German Siemens (Siemens). Leverage the power of discrete event simulation for throughput analysis and optimization to improve manufacturing system performance
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202303-0898",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2201.0006"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "2201.0006"
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v2201.0006"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2201.0006",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-27402"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dennis Herrmann (@dhn_)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
}
],
"trust": 0.7
},
"cve": "CVE-2023-27402",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2023-18932",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2023-004924",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-27402",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-27402",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2023-004924",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2023-27402",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-18932",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202303-1088",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Tecnomatix Plant Simulation (All versions \u003c V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334). Siemens\u0027 Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. Siemens Tecnomatix Plant Simulation is an industrial control equipment of German Siemens (Siemens). Leverage the power of discrete event simulation for throughput analysis and optimization to improve manufacturing system performance",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-27402",
"trust": 4.5
},
{
"db": "SIEMENS",
"id": "SSA-847261",
"trust": 3.0
},
{
"db": "JVN",
"id": "JVNVU97514209",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-20334",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-327",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2023-18932",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"id": "VAR-202303-0898",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18932"
}
],
"trust": 0.94765625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18932"
}
]
},
"last_update_date": "2023-12-18T11:44:22.385000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf"
},
{
"title": "Patch for Siemens Tecnomatix Plant Simulation Out-of-Bounds Read Vulnerability (CNVD-2023-18932)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/415671"
},
{
"title": "Siemens Tecnomatix Plant Simulation Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=228937"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu97514209/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-27402"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-27402/"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-16T00:00:00",
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"date": "2023-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"date": "2023-11-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"date": "2023-03-14T10:15:29.240000",
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"date": "2023-03-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-16T00:00:00",
"db": "ZDI",
"id": "ZDI-23-327"
},
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18932"
},
{
"date": "2023-11-02T07:30:00",
"db": "JVNDB",
"id": "JVNDB-2023-004924"
},
{
"date": "2023-03-16T19:01:28.430000",
"db": "NVD",
"id": "CVE-2023-27402"
},
{
"date": "2023-03-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-004924"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1088"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.