var-202303-1298
Vulnerability from variot

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server Exists in an inadequate validation of data reliability vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric).

Schneider Electric IGSS Data Server has a data forgery vulnerability

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202303-1298",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "igss data server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "16.0.0.23040"
      },
      {
        "model": "igss dashboard",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "16.0.0.23040"
      },
      {
        "model": "custom reports",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "16.0.0.23040"
      },
      {
        "model": "igss dashboard",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "custom reports",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "igss data server",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "igss",
        "scope": null,
        "trust": 0.7,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric igss data server",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=v16.0.0.23040"
      },
      {
        "model": "electric igss dashboard",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=v16.0.0.23040"
      },
      {
        "model": "electric custom reports",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=v16.0.0.23040"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "16.0.0.23040",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "16.0.0.23040",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "16.0.0.23040",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "kimiya",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2023-27982",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-29373",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-27982",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "id": "CVE-2023-27982",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-27982",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "cybersecurity@se.com",
            "id": "CVE-2023-27982",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2023-27982",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-29373",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202303-1555",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server Exists in an inadequate validation of data reliability vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric). \n\r\n\r\nSchneider Electric IGSS Data Server has a data forgery vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-27982",
        "trust": 4.5
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2023-073-04",
        "trust": 3.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-082-04",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU94559502",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-19652",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-23-337",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2023.1792",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "id": "VAR-202303-1298",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:54:51.859000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Schneider Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf"
      },
      {
        "title": "Patch for Schneider Electric IGSS Data Server Data Forgery Vulnerability (CNVD-2023-29373)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/419136"
      },
      {
        "title": "Schneider Electric IGSS Data Server Repair measures for data forgery problem vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=230403"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-345",
        "trust": 1.0
      },
      {
        "problemtype": "Inadequate verification of data reliability (CWE-345) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.7,
        "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu94559502/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27982"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-04"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-27982/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2023.1792"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-16T00:00:00",
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "date": "2023-04-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "date": "2023-11-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "date": "2023-03-21T07:15:08.410000",
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "date": "2023-03-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-16T00:00:00",
        "db": "ZDI",
        "id": "ZDI-23-337"
      },
      {
        "date": "2023-04-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-29373"
      },
      {
        "date": "2023-11-09T03:11:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      },
      {
        "date": "2023-03-24T18:08:45.557000",
        "db": "NVD",
        "id": "CVE-2023-27982"
      },
      {
        "date": "2023-03-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Schneider\u00a0Electric\u00a0 Insufficient Validation of Data Trust in Products Vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-005624"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "data forgery",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1555"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.