VDE-2023-012

Vulnerability from csaf_mbconnectlinegmbh - Published: 2023-08-17 12:00 - Updated: 2023-08-17 12:00
Summary
MB connect line: Cross-site Scripting vulnerability in mbNET/mbNET.rokey
Notes
Summary: A stored XXS vulnerability has been found in mbNET and mbNET/.rokey in all versions before 7.3.2.
Impact: A remote, authenticated attacker can fully compromise the browser session of all users accessing the devices web interface.
Remediation: Update to 7.3.2

A vulnerability in Red Lion Europe mbNET/mbNET.rokey and Helmholz REX 200 and REX 250 devices with firmware lower 7.3.2 allows an authenticated remote attacker with high privileges to inject malicious HTML or JavaScript code (XSS).

CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Vendor Fix Update to 7.3.2
Acknowledgments
CERT@VDE certvde.com

{
  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "A stored XXS vulnerability has been found in\u00a0mbNET and\u00a0mbNET/.rokey in all versions\u00a0before 7.3.2.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "A remote, authenticated attacker can fully compromise the browser session of all users accessing the devices web interface.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "Update to 7.3.2",
        "title": "Remediation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "security-team@mbconnectline.de",
      "name": "MB connect line GmbH",
      "namespace": "https://mbconnectline.com"
    },
    "references": [
      {
        "category": "external",
        "summary": "CERT@VDE Security Advisories for MB connect line GmbH",
        "url": "https://certvde.com/en/advisories/vendor/mbconnectline/"
      },
      {
        "category": "self",
        "summary": "VDE-2023-012: MB connect line: Cross-site Scripting vulnerability in mbNET/mbNET.rokey - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2023-012/"
      },
      {
        "category": "self",
        "summary": "VDE-2023-012: MB connect line: Cross-site Scripting vulnerability in mbNET/mbNET.rokey - CSAF",
        "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-012.json"
      }
    ],
    "title": "MB connect line: Cross-site Scripting vulnerability in mbNET/mbNET.rokey",
    "tracking": {
      "aliases": [
        "VDE-2023-012"
      ],
      "current_release_date": "2023-08-17T12:00:00.000Z",
      "generator": {
        "date": "2025-06-05T07:56:19.766Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.27"
        }
      },
      "id": "VDE-2023-012",
      "initial_release_date": "2023-08-17T12:00:00.000Z",
      "revision_history": [
        {
          "date": "2023-08-17T12:00:00.000Z",
          "number": "1",
          "summary": "Initial revision."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "\u003c7.3.2",
                    "product": {
                      "name": "mbNET \u003c7.3.2",
                      "product_id": "CSAFPID-51001"
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "7.3.2",
                    "product": {
                      "name": "mbNET 7.3.2",
                      "product_id": "CSAFPID-52001"
                    }
                  }
                ],
                "category": "product_name",
                "name": "mbNET"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "\u003c7.3.2",
                    "product": {
                      "name": "mbNET.rokey \u003c7.3.2",
                      "product_id": "CSAFPID-51002"
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "7.3.2",
                    "product": {
                      "name": "mbNET.rokey 7.3.2",
                      "product_id": "CSAFPID-52002"
                    }
                  }
                ],
                "category": "product_name",
                "name": "mbNET.rokey"
              }
            ],
            "category": "product_family",
            "name": "Software"
          }
        ],
        "category": "vendor",
        "name": "MB connect line"
      },
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "\u003c7.3.2",
                    "product": {
                      "name": "mbNET \u003c7.3.2",
                      "product_id": "CSAFPID-51003"
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "7.3.2",
                    "product": {
                      "name": "mbNET 7.3.2",
                      "product_id": "CSAFPID-52003"
                    }
                  }
                ],
                "category": "product_name",
                "name": "mbNET"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "\u003c7.3.2",
                    "product": {
                      "name": "mbNET.rokey \u003c7.3.2",
                      "product_id": "CSAFPID-51004"
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "7.3.2",
                    "product": {
                      "name": "mbNET.rokey 7.3.2",
                      "product_id": "CSAFPID-52004"
                    }
                  }
                ],
                "category": "product_name",
                "name": "mbNET.rokey"
              }
            ],
            "category": "product_family",
            "name": "Software"
          }
        ],
        "category": "vendor",
        "name": "Red Lion Europe"
      }
    ],
    "product_groups": [
      {
        "group_id": "CSAFGID-0001",
        "product_ids": [
          "CSAFPID-51001",
          "CSAFPID-51002",
          "CSAFPID-51003",
          "CSAFPID-51004"
        ],
        "summary": "Affected products "
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2023-34412",
      "cwe": {
        "id": "CWE-79",
        "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
      },
      "notes": [
        {
          "category": "description",
          "text": "A vulnerability in Red Lion Europe mbNET/mbNET.rokey and Helmholz REX 200 and REX 250 devices with firmware lower 7.3.2 allows an\nauthenticated remote attacker with high privileges to inject malicious HTML or JavaScript code (XSS).",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-52001",
          "CSAFPID-52002",
          "CSAFPID-52003",
          "CSAFPID-52004"
        ],
        "known_affected": [
          "CSAFPID-51001",
          "CSAFPID-51002",
          "CSAFPID-51003",
          "CSAFPID-51004"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to 7.3.2",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "environmentalScore": 4.8,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "temporalScore": 4.8,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-51001",
            "CSAFPID-51002",
            "CSAFPID-51003",
            "CSAFPID-51004"
          ]
        }
      ],
      "title": "CVE-2023-34412"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…