CWE-306
AllowedMissing Authentication for Critical Function
Abstraction: Base · Status: Draft
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
3583 vulnerabilities reference this CWE, most recent first.
CVE-2023-5253 (GCVE-0-2023-5253)
Vulnerability from cvelistv5 – Published: 2024-01-15 10:53 – Updated: 2025-06-17 21:09- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Nozomi Networks | Guardian |
Affected:
0 , < 23.3.0
(semver)
|
|
| Nozomi Networks | CMC |
Affected:
0 , < 23.3.0
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:52:08.520Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5253",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-16T16:05:53.153585Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:09:23.231Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Guardian",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CMC",
"vendor": "Nozomi Networks",
"versions": [
{
"lessThan": "23.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session."
}
],
"datePublic": "2024-01-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eA missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-20T11:38:34.932Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://security.nozominetworks.com/NN-2023:12-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v23.3.0 or later.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Upgrade to v23.3.0 or later."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eUse internal firewall features to limit access to the web management interface.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Use internal firewall features to limit access to the web management interface."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2023-5253",
"datePublished": "2024-01-15T10:53:56.305Z",
"dateReserved": "2023-09-28T12:41:27.922Z",
"dateUpdated": "2025-06-17T21:09:23.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4884 (GCVE-0-2023-4884)
Vulnerability from cvelistv5 – Published: 2023-10-03 14:46 – Updated: 2024-09-19 19:55- CWE-306 - Missing Authentication for Critical Function
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:38:01.041Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-open5gs"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4884",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T19:55:38.993959Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T19:55:50.558Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Open5GS",
"vendor": "Open5GS",
"versions": [
{
"status": "affected",
"version": "2.4.10 and prior"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Pablo Valle Alvear"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker could send an HTTP request to an Open5GS endpoint and retrieve the information stored on the device due to the lack of Authentication."
}
],
"value": "An attacker could send an HTTP request to an Open5GS endpoint and retrieve the information stored on the device due to the lack of Authentication."
}
],
"impacts": [
{
"capecId": "CAPEC-12",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-12 Choosing Message Identifier"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-03T14:46:57.814Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-open5gs"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Open5GS is working on a fix for the reported vulnerabilities."
}
],
"value": "Open5GS is working on a fix for the reported vulnerabilities."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Multiple vulnerabilities in Open5GS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2023-4884",
"datePublished": "2023-10-03T14:46:57.814Z",
"dateReserved": "2023-09-11T09:31:24.278Z",
"dateUpdated": "2024-09-19T19:55:50.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4857 (GCVE-0-2023-4857)
Vulnerability from cvelistv5 – Published: 2024-04-15 18:00 – Updated: 2024-08-02 07:38- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | SMM, SMM2, FPC |
Affected:
various
|
|
| lenovo | fan_power_controller |
Affected:
0 , < fhet62a-3.50
(custom)
cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:* |
|
| lenovo | system_management_module_firmware |
Affected:
1.24 , < tesm40b-1.27
(custom)
cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fan_power_controller",
"vendor": "lenovo",
"versions": [
{
"lessThan": "fhet62a-3.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "system_management_module_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "tesm40b-1.27",
"status": "affected",
"version": "1.24",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T17:28:48.672549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T19:59:02.276Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:38:00.772Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SMM, SMM2, FPC",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\u003c/span\u003e\n\n"
}
],
"value": "\nAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-15T18:00:03.660Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-140420\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-140420\u003c/a\u003e\u0026nbsp; \u0026nbsp;\n\n\u003cbr\u003e"
}
],
"value": "\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: https://support.lenovo.com/us/en/product_security/LEN-140420 \u00a0 \u00a0\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2023-4857",
"datePublished": "2024-04-15T18:00:03.660Z",
"dateReserved": "2023-09-08T19:23:06.855Z",
"dateUpdated": "2024-08-02T07:38:00.772Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4815 (GCVE-0-2023-4815)
Vulnerability from cvelistv5 – Published: 2023-09-07 06:26 – Updated: 2024-09-26 19:25- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| answerdev | answerdev/answer |
Affected:
unspecified , < v1.1.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:38:00.728Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://huntr.dev/bounties/4cd3eeb4-57c9-4af2-ad19-2166c9e0fd2c"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/answerdev/answer/commit/e75142a55546e01d8904f59db228422561f51666"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4815",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-26T19:25:22.895345Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-26T19:25:34.623Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "answerdev/answer",
"vendor": "answerdev",
"versions": [
{
"lessThan": "v1.1.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Missing Authentication for Critical Function in GitHub repository answerdev/answer prior to v1.1.3."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-07T06:26:09.174Z",
"orgId": "c09c270a-b464-47c1-9133-acb35b22c19a",
"shortName": "@huntrdev"
},
"references": [
{
"url": "https://huntr.dev/bounties/4cd3eeb4-57c9-4af2-ad19-2166c9e0fd2c"
},
{
"url": "https://github.com/answerdev/answer/commit/e75142a55546e01d8904f59db228422561f51666"
}
],
"source": {
"advisory": "4cd3eeb4-57c9-4af2-ad19-2166c9e0fd2c",
"discovery": "EXTERNAL"
},
"title": "Missing Authentication for Critical Function in answerdev/answer"
}
},
"cveMetadata": {
"assignerOrgId": "c09c270a-b464-47c1-9133-acb35b22c19a",
"assignerShortName": "@huntrdev",
"cveId": "CVE-2023-4815",
"datePublished": "2023-09-07T06:26:09.174Z",
"dateReserved": "2023-09-07T06:25:54.449Z",
"dateUpdated": "2024-09-26T19:25:34.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4699 (GCVE-0-2023-4699)
Vulnerability from cvelistv5 – Published: 2023-11-06 05:02 – Updated: 2025-12-16 18:23- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.mitsubishielectric.com/en/psirt/vulne… | vendor-advisory |
| https://jvn.jp/vu/JVNVU94620134/ | government-resource |
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:37:59.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-013_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU94620134/"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4699",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:08:23.435701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-16T18:23:26.501Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MR/UA1",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MR/UA1",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MS/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MS/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-16MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-32MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-48MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-64MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-80MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3U-128MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-32MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-64MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-96MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-96MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MR/D-T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MR/DS-T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-32MT-LT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-32MT-LT-2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MT/D-P4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3UC-16MT/DSS-P4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-14MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-24MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-40MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3G-60MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GC-32MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GC-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-24MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GE-40MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-24MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-40MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-60MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-24MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-40MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3GA-60MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-10MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-14MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-20MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/ES-2AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MR/ES-2AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3S-30MT/ESS-2AD",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-10MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-14MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-20MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-30MT-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-10MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-14MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-20MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC-F Series FX3SA-30MR-CM",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-64MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-96MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-96MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5-40SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5-80SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5-40SSC-S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5-80SSC-S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R04CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R08CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R120CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R04ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R08ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R120ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R08PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R120PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16MTCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32MTCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R64MTCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78G8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78G32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78G64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78GHV",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD78GHW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77MS2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77MS4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77MS8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77MS16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77GF4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77GF8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77GF16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series RD77GF32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L Series LD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L Series LD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series Q172DSCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series Q173DSCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series Q170MSCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77MS2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77MS4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77MS16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77GF4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77GF8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC Q Series QD77GF16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC L Series LD77MS2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC L Series LD77MS4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC L Series LD77MS16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800V Series M800VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2051W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800V Series M800VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2052W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80V Series M80V",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2053W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80V Series M80VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2054W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800 Series M800W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2005W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M800 Series M800S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2006W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80 Series M80",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2007W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M80 Series M80W",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2008W000all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC E80 Series E80",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-2009W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M720VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M730VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M750VW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1015W002 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M720VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M730VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M700V Series M750VS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1012W002 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC M70V Series M70V",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1018W000 all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Mitsubishi Electric CNC E70 Series E70",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "System Number BND-1022W000 all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.\u003cbr\u003e"
}
],
"value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Denial of Service(DoS), disclose or tamper with information"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T23:26:11.473Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-013_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU94620134/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Arbitrary Command Execution Vulnerability in Mitsubishi Electric proprietary protocol communication of multiple FA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2023-4699",
"datePublished": "2023-11-06T05:02:15.543Z",
"dateReserved": "2023-09-01T05:21:41.572Z",
"dateUpdated": "2025-12-16T18:23:26.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-4516 (GCVE-0-2023-4516)
Vulnerability from cvelistv5 – Published: 2023-09-14 08:54 – Updated: 2025-02-27 20:52- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | IGSS Update Service (IGSSupdateservice.exe) |
Affected:
v16.0.0.23211 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:31:06.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4516",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:51:14.783705Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:52:17.879Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IGSS Update Service (IGSSupdateservice.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v16.0.0.23211 and prior"
}
]
}
],
"datePublic": "2023-09-12T08:53:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-14T08:54:53.673Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-4516",
"datePublished": "2023-09-14T08:54:53.673Z",
"dateReserved": "2023-08-24T10:47:22.919Z",
"dateUpdated": "2025-02-27T20:52:17.879Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4506 (GCVE-0-2023-4506)
Vulnerability from cvelistv5 – Published: 2023-09-26 01:51 – Updated: 2026-04-08 16:33- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| cyberlord92 | Active Directory Integration / LDAP Integration |
Affected:
0 , ≤ 4.1.10
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:31:05.501Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/0585969d-dd08-4058-9d72-138a55a2cdf1?source=cve"
},
{
"tags": [
"x_transferred"
],
"url": "https://wordpress.org/plugins/ldap-login-for-intranet-sites/"
},
{
"tags": [
"x_transferred"
],
"url": "https://medium.com/%40cybertrinchera/cve-2023-4506-cve-2023-4505-ldap-passback-on-miniorange-plugins-ca7328c84313"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4506",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T18:25:38.149079Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T19:19:10.246Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Active Directory Integration / LDAP Integration",
"vendor": "cyberlord92",
"versions": [
{
"lessThanOrEqual": "4.1.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pedro Jos\u00e9 Navas P\u00e9rez"
}
],
"descriptions": [
{
"lang": "en",
"value": "The Active Directory Integration / LDAP Integration plugin for WordPress is vulnerable to LDAP Passback in versions up to, and including, 4.1.10. This is due to insufficient validation when changing the LDAP server. This makes it possible for authenticated attackers, with administrative access and above, to change the LDAP server and retrieve the credentials for the original LDAP server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.2,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-08T16:33:23.785Z",
"orgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
"shortName": "Wordfence"
},
"references": [
{
"url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/0585969d-dd08-4058-9d72-138a55a2cdf1?source=cve"
},
{
"url": "https://wordpress.org/plugins/ldap-login-for-intranet-sites/"
},
{
"url": "https://medium.com/%40cybertrinchera/cve-2023-4506-cve-2023-4505-ldap-passback-on-miniorange-plugins-ca7328c84313"
},
{
"url": "https://plugins.trac.wordpress.org/changeset/2973005/ldap-login-for-intranet-sites"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-09-25T00:00:00.000Z",
"value": "Disclosed"
}
],
"title": "Active Directory Integration / LDAP Integration \u003c= 4.1.10 - LDAP Passback"
}
},
"cveMetadata": {
"assignerOrgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
"assignerShortName": "Wordfence",
"cveId": "CVE-2023-4506",
"datePublished": "2023-09-26T01:51:13.277Z",
"dateReserved": "2023-08-23T21:46:35.528Z",
"dateUpdated": "2026-04-08T16:33:23.785Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-4505 (GCVE-0-2023-4505)
Vulnerability from cvelistv5 – Published: 2023-09-26 01:51 – Updated: 2026-04-08 16:40- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| cyberlord92 | Staff/Employee Business Directory for Active Directory |
Affected:
0 , ≤ 1.2.3
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:31:05.497Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/1ea40b96-4693-4f98-8e6e-2ed8186cedd8?source=cve"
},
{
"tags": [
"x_transferred"
],
"url": "https://wordpress.org/plugins/ldap-ad-staff-employee-directory-search/"
},
{
"tags": [
"x_transferred"
],
"url": "https://medium.com/%40cybertrinchera/cve-2023-4506-cve-2023-4505-ldap-passback-on-miniorange-plugins-ca7328c84313"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4505",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T18:25:35.113466Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T19:19:01.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Staff/Employee Business Directory for Active Directory",
"vendor": "cyberlord92",
"versions": [
{
"lessThanOrEqual": "1.2.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pedro Jos\u00e9 Navas P\u00e9rez"
}
],
"descriptions": [
{
"lang": "en",
"value": "The Staff / Employee Business Directory for Active Directory plugin for WordPress is vulnerable to LDAP Passback in versions up to, and including, 1.2.3. This is due to insufficient validation when changing the LDAP server. This makes it possible for authenticated attackers, with administrative access and above, to change the LDAP server and retrieve the credentials for the original LDAP server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.2,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-08T16:40:49.605Z",
"orgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
"shortName": "Wordfence"
},
"references": [
{
"url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/1ea40b96-4693-4f98-8e6e-2ed8186cedd8?source=cve"
},
{
"url": "https://wordpress.org/plugins/ldap-ad-staff-employee-directory-search/"
},
{
"url": "https://medium.com/%40cybertrinchera/cve-2023-4506-cve-2023-4505-ldap-passback-on-miniorange-plugins-ca7328c84313"
},
{
"url": "https://plugins.trac.wordpress.org/changeset/2973020/"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-09-25T00:00:00.000Z",
"value": "Disclosed"
}
],
"title": "Staff / Employee Business Directory for Active Directory \u003c= 1.2.3 - Authenticated (Admin+) LDAP Passback"
}
},
"cveMetadata": {
"assignerOrgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
"assignerShortName": "Wordfence",
"cveId": "CVE-2023-4505",
"datePublished": "2023-09-26T01:51:13.836Z",
"dateReserved": "2023-08-23T21:43:23.252Z",
"dateUpdated": "2026-04-08T16:40:49.605Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-3104 (GCVE-0-2023-3104)
Vulnerability from cvelistv5 – Published: 2023-11-22 11:54 – Updated: 2024-08-02 06:48 Unsupported When Assigned- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Unitree Robotics | A1 |
Affected:
1.16
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:07.001Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-unitree-robotics-a1"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "A1",
"vendor": "Unitree Robotics",
"versions": [
{
"status": "affected",
"version": "1.16"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Alberto Miguel Diez"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Adri\u00e1n Campazas Vega"
}
],
"datePublic": "2023-11-21T11:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Lack of authentication vulnerability. An unauthenticated local user is able to see through the cameras using the web server due to the lack of any form of authentication."
}
],
"value": "Lack of authentication vulnerability. An unauthenticated local user is able to see through the cameras using the web server due to the lack of any form of authentication."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-22T11:54:30.983Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-unitree-robotics-a1"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected robot is in the discontinuation stage. The manufacturer recommends changing the default network password, as well as disabling network functions if they are not required."
}
],
"value": "The affected robot is in the discontinuation stage. The manufacturer recommends changing the default network password, as well as disabling network functions if they are not required."
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Missing Authentication for Critical Function in Unitree Robotics A1",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2023-3104",
"datePublished": "2023-11-22T11:54:30.983Z",
"dateReserved": "2023-06-05T12:33:14.940Z",
"dateUpdated": "2024-08-02T06:48:07.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2827 (GCVE-0-2023-2827)
Vulnerability from cvelistv5 – Published: 2023-06-13 02:36 – Updated: 2025-01-03 02:07- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| SAP_SE | SAP Plant Connectivity |
Affected:
1.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:33:05.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://launchpad.support.sap.com/#/notes/3301942"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2827",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T02:07:14.772142Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T02:07:52.209Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SAP Plant Connectivity",
"vendor": "SAP_SE",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSAP Plant Connectivity - version 15.5 (PCo) or the Production Connector for SAP Digital Manufacturing - version 1.0, do not validate the signature of the JSON Web Token (JWT) in the HTTP request sent from SAP Digital Manufacturing. Therefore, unauthorized callers from the internal network could send service requests to PCo or the Production Connector, which could have an impact on the integrity of the integration with SAP Digital Manufacturing.\u003c/p\u003e"
}
],
"value": "SAP Plant Connectivity - version 15.5 (PCo) or the Production Connector for SAP Digital Manufacturing - version 1.0, do not validate the signature of the JSON Web Token (JWT) in the HTTP request sent from SAP Digital Manufacturing. Therefore, unauthorized callers from the internal network could send service requests to PCo or the Production Connector, which could have an impact on the integrity of the integration with SAP Digital Manufacturing.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.9,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "eng",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T02:36:18.158Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"url": "https://launchpad.support.sap.com/#/notes/3301942"
},
{
"url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Missing Authentication in SAP Plant Connectivity and Production Connector for SAP Digital",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2023-2827",
"datePublished": "2023-06-13T02:36:18.158Z",
"dateReserved": "2023-05-22T06:34:19.652Z",
"dateUpdated": "2025-01-03T02:07:52.209Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
- Divide the software into anonymous, normal, privileged, and administrative areas. Identify which of these areas require a proven user identity, and use a centralized authentication capability.
- Identify all potential communication channels, or other means of interaction with the software, to ensure that all channels are appropriately protected, including those channels that are assumed to be accessible only by authorized parties. Developers sometimes perform authentication at the primary channel, but open up a secondary channel that is assumed to be private. For example, a login mechanism may be listening on one network port, but after successful authentication, it may open up a second port where it waits for the connection, but avoids authentication because it assumes that only the authenticated party will connect to the port.
- In general, if the software or protocol allows a single session or user state to persist across multiple connections or channels, authentication and appropriate credential management need to be used throughout.
Mitigation MIT-15
For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation
- Where possible, avoid implementing custom, "grow-your-own" authentication routines and consider using authentication capabilities as provided by the surrounding framework, operating system, or environment. These capabilities may avoid common weaknesses that are unique to authentication; support automatic auditing and tracking; and make it easier to provide a clear separation between authentication tasks and authorization tasks.
- In environments such as the World Wide Web, the line between authentication and authorization is sometimes blurred. If custom authentication routines are required instead of those provided by the server, then these routines must be applied to every single page, since these pages could be requested directly.
Mitigation MIT-4.5
Strategy: Libraries or Frameworks
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator [REF-45].
Mitigation
When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data [REF-1297] [REF-1298] [REF-1302].
CAPEC-12: Choosing Message Identifier
This pattern of attack is defined by the selection of messages distributed via multicast or public information channels that are intended for another client by determining the parameter value assigned to that client. This attack allows the adversary to gain access to potentially privileged information, and to possibly perpetrate other attacks through the distribution means by impersonation. If the channel/message being manipulated is an input rather than output mechanism for the system, (such as a command bus), this style of attack could be used to change the adversary's identifier to more a privileged one.
CAPEC-166: Force the System to Reset Values
An attacker forces the target into a previous state in order to leverage potential weaknesses in the target dependent upon a prior configuration or state-dependent factors. Even in cases where an attacker may not be able to directly control the configuration of the targeted application, they may be able to reset the configuration to a prior state since many applications implement reset functions.
CAPEC-216: Communication Channel Manipulation
An adversary manipulates a setting or parameter on communications channel in order to compromise its security. This can result in information exposure, insertion/removal of information from the communications stream, and/or potentially system compromise.
CAPEC-36: Using Unpublished Interfaces or Functionality
An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.
CAPEC-62: Cross Site Request Forgery
An attacker crafts malicious web links and distributes them (via web pages, email, etc.), typically in a targeted manner, hoping to induce users to click on the link and execute the malicious action against some third-party application. If successful, the action embedded in the malicious link will be processed and accepted by the targeted application with the users' privilege level. This type of attack leverages the persistence and implicit trust placed in user session cookies by many web applications today. In such an architecture, once the user authenticates to an application and a session cookie is created on the user's system, all following transactions for that session are authenticated using that cookie including potential actions initiated by an attacker and simply "riding" the existing session cookie.