Common Weakness Enumeration
CWE-668
DiscouragedExposure of Resource to Wrong Sphere
Abstraction: Class · Status: Draft
The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
1248 vulnerabilities reference this CWE, most recent first.
CVE-2022-22732 (GCVE-0-2022-22732)
Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2025-02-05 20:08
VLAI
EPSS
VEX
Summary
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Power Commission |
Affected:
All , < V2.22
(custom)
|
Date Public
2022-06-14 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:48.946Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-22732",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:50:45.469109Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:08:57.280Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Power Commission",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.22",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-06-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-22732",
"datePublished": "2023-01-30T00:00:00.000Z",
"dateReserved": "2022-01-06T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:08:57.280Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-22515 (GCVE-0-2022-22515)
Vulnerability from cvelistv5 – Published: 2022-04-07 18:21 – Updated: 2024-09-16 17:59
VLAI
EPSS
VEX
Title
A component of the CODESYS Control runtime system allows read and write access to configuration files
Summary
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
Severity
8.1 (High)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://customers.codesys.com/index.php?eID=dumpF… | x_refsource_CONFIRM |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Embedded Target Visu Toolkit |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Remote Target Visu Toolkit |
Affected:
V3 , < V3.5.17.40
(custom)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for Beckhoff CX9020 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
V4 , < V4.5.0.0
(custom)
|
Date Public
2022-06-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:14:55.437Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.17.40",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Beckhoff CX9020 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V4",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-06-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-12T07:45:29.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "A component of the CODESYS Control runtime system allows read and write access to configuration files",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-06-01T10:00:00.000Z",
"ID": "CVE-2022-22515",
"STATE": "PUBLIC",
"TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CODESYS Control RTE (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Control Win (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS HMI (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Development System V3",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Control Runtime System Toolkit",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Embedded Target Visu Toolkit",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Remote Target Visu Toolkit",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V3",
"version_value": "V3.5.17.40"
}
]
}
},
{
"product_name": "CODESYS Control for BeagleBone SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for Beckhoff CX9020 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for emPC-A/iMX6 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for IOT2000 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for Linux SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PFC100 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PFC200 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PLCnext SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for Raspberry Pi SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "V4",
"version_value": "V4.5.0.0"
}
]
}
}
]
},
"vendor_name": "CODESYS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668 Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=",
"refsource": "CONFIRM",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-22515",
"datePublished": "2022-04-07T18:21:16.280Z",
"dateReserved": "2022-01-03T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:59:22.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21947 (GCVE-0-2022-21947)
Vulnerability from cvelistv5 – Published: 2022-04-01 06:40 – Updated: 2024-09-16 19:20
VLAI
EPSS
VEX
Title
rancher desktop: Dashboard API is network accessible
Summary
A Exposure of Resource to Wrong Sphere vulnerability in Rancher Desktop of SUSE allows attackers in the local network to connect to the Dashboard API (steve) to carry out arbitrary actions. This issue affects: SUSE Rancher Desktop versions prior to V.
Severity
8.3 (High)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
Date Public
2022-03-25 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:00:54.558Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1197491"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rancher",
"vendor": "SUSE",
"versions": [
{
"lessThan": "V",
"status": "affected",
"version": "Desktop",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-03-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Exposure of Resource to Wrong Sphere vulnerability in Rancher Desktop of SUSE allows attackers in the local network to connect to the Dashboard API (steve) to carry out arbitrary actions. This issue affects: SUSE Rancher Desktop versions prior to V."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-29T00:00:00.000Z",
"orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"shortName": "suse"
},
"references": [
{
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1197491"
}
],
"source": {
"advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1197491",
"defect": [
"1197491"
],
"discovery": "INTERNAL"
},
"title": "rancher desktop: Dashboard API is network accessible",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"assignerShortName": "suse",
"cveId": "CVE-2022-21947",
"datePublished": "2022-04-01T06:40:10.168Z",
"dateReserved": "2021-12-16T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:20:21.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21718 (GCVE-0-2022-21718)
Vulnerability from cvelistv5 – Published: 2022-03-22 16:25 – Updated: 2025-04-23 18:45
VLAI
EPSS
VEX
Title
Renderers can obtain access to random bluetooth device without permission in Electron
Summary
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. A vulnerability in versions prior to `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` allows renderers to obtain access to a bluetooth device via the web bluetooth API if the app has not configured a custom `select-bluetooth-device` event handler. This has been patched and Electron versions `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` contain the fix. Code from the GitHub Security Advisory can be added to the app to work around the issue.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://github.com/electron/electron/security/adv… | x_refsource_CONFIRM |
| https://github.com/electron/electron/pull/32178 | x_refsource_MISC |
| https://github.com/electron/electron/pull/32240 | x_refsource_MISC |
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:53:35.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/electron/electron/security/advisories/GHSA-3p22-ghq8-v749"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/electron/electron/pull/32178"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/electron/electron/pull/32240"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21718",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T14:08:46.712540Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T18:45:03.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "electron",
"vendor": "electron",
"versions": [
{
"status": "affected",
"version": "\u003c 13.6.6"
},
{
"status": "affected",
"version": "\u003e= 14.0.0-beta.1, \u003c 14.2.4"
},
{
"status": "affected",
"version": "\u003e= 15.0.0-beta.1, \u003c 15.3.5"
},
{
"status": "affected",
"version": "\u003e= 16.0.0-beta.1, \u003c 16.0.6"
},
{
"status": "affected",
"version": "\u003e= 17.0.0-alpha.1, \u003c= 17.0.0-alpha.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. A vulnerability in versions prior to `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` allows renderers to obtain access to a bluetooth device via the web bluetooth API if the app has not configured a custom `select-bluetooth-device` event handler. This has been patched and Electron versions `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` contain the fix. Code from the GitHub Security Advisory can be added to the app to work around the issue."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-22T16:25:11.000Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/electron/electron/security/advisories/GHSA-3p22-ghq8-v749"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/electron/electron/pull/32178"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/electron/electron/pull/32240"
}
],
"source": {
"advisory": "GHSA-3p22-ghq8-v749",
"discovery": "UNKNOWN"
},
"title": "Renderers can obtain access to random bluetooth device without permission in Electron",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-advisories@github.com",
"ID": "CVE-2022-21718",
"STATE": "PUBLIC",
"TITLE": "Renderers can obtain access to random bluetooth device without permission in Electron"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "electron",
"version": {
"version_data": [
{
"version_value": "\u003c 13.6.6"
},
{
"version_value": "\u003e= 14.0.0-beta.1, \u003c 14.2.4"
},
{
"version_value": "\u003e= 15.0.0-beta.1, \u003c 15.3.5"
},
{
"version_value": "\u003e= 16.0.0-beta.1, \u003c 16.0.6"
},
{
"version_value": "\u003e= 17.0.0-alpha.1, \u003c= 17.0.0-alpha.5"
}
]
}
}
]
},
"vendor_name": "electron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. A vulnerability in versions prior to `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` allows renderers to obtain access to a bluetooth device via the web bluetooth API if the app has not configured a custom `select-bluetooth-device` event handler. This has been patched and Electron versions `17.0.0-alpha.6`, `16.0.6`, `15.3.5`, `14.2.4`, and `13.6.6` contain the fix. Code from the GitHub Security Advisory can be added to the app to work around the issue."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/electron/electron/security/advisories/GHSA-3p22-ghq8-v749",
"refsource": "CONFIRM",
"url": "https://github.com/electron/electron/security/advisories/GHSA-3p22-ghq8-v749"
},
{
"name": "https://github.com/electron/electron/pull/32178",
"refsource": "MISC",
"url": "https://github.com/electron/electron/pull/32178"
},
{
"name": "https://github.com/electron/electron/pull/32240",
"refsource": "MISC",
"url": "https://github.com/electron/electron/pull/32240"
}
]
},
"source": {
"advisory": "GHSA-3p22-ghq8-v749",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2022-21718",
"datePublished": "2022-03-22T16:25:12.000Z",
"dateReserved": "2021-11-16T00:00:00.000Z",
"dateUpdated": "2025-04-23T18:45:03.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-20917 (GCVE-0-2022-20917)
Vulnerability from cvelistv5 – Published: 2023-09-15 02:12 – Updated: 2024-09-25 14:13
VLAI
EPSS
VEX
Summary
A vulnerability in the Extensible Messaging and Presence Protocol (XMPP) message processing feature of Cisco Jabber could allow an authenticated, remote attacker to manipulate the content of XMPP messages that are used by the affected application.
This vulnerability is due to the improper handling of nested XMPP messages within requests that are sent to the Cisco Jabber client software. An attacker could exploit this vulnerability by connecting to an XMPP messaging server and sending crafted XMPP messages to an affected Jabber client. A successful exploit could allow the attacker to manipulate the content of XMPP messages, possibly allowing the attacker to cause the Jabber client application to perform unsafe actions.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco Jabber |
Affected:
10.5(0)
Affected: 10.5(1) Affected: 10.5(2) Affected: 10.5(3) Affected: 10.5(4) Affected: 10.5(5) Affected: 10.5(6) Affected: 10.6(0) Affected: 10.6(1) Affected: 10.6(2) Affected: 10.6(3) Affected: 10.6(4) Affected: 10.6(5) Affected: 10.6(6) Affected: 10.6(7) Affected: 10.6(10) Affected: 10.6(11) Affected: 10.6(12) Affected: 10.6(8) Affected: 10.6(9) Affected: 11.0(0) Affected: 11.0(1) Affected: 11.0(2) Affected: 11.1(0) Affected: 11.1(1) Affected: 11.1(2) Affected: 11.1(3) Affected: 11.1(4) Affected: 11.5(0) Affected: 11.5(1) Affected: 11.5(2) Affected: 11.5(3) Affected: 11.5(4) Affected: 11.5(5) Affected: 11.5(6) Affected: 11.6(0) Affected: 11.6(1) Affected: 11.6(2) Affected: 11.6(3) Affected: 11.6(4) Affected: 11.7(0) Affected: 11.7(1) Affected: 11.7(2) Affected: 11.8(0) Affected: 11.8(1) Affected: 11.8(2) Affected: 11.8(3) Affected: 11.8(4) Affected: 11.8(5) Affected: 11.9(0) Affected: 11.9(1) Affected: 11.9(2) Affected: 11.9(3) Affected: 12.0(0) Affected: 12.0(1) Affected: 12.1(0) Affected: 12.1(1) Affected: 12.1(2) Affected: 12.1(3) Affected: 12.1(4) Affected: 12.1(5) Affected: 12.5(0) Affected: 12.5(1) Affected: 12.5(2) Affected: 12.5(3) Affected: 12.5(4) Affected: 12.6(0) Affected: 12.6(1) Affected: 12.6(2) Affected: 12.6(3) Affected: 12.6(4) Affected: 12.6(5) Affected: 12.7(0) Affected: 12.7(1) Affected: 12.7(2) Affected: 12.7(3) Affected: 12.7(4) Affected: 12.7(5) Affected: 12.8(0) Affected: 12.8(1) Affected: 12.8(2) Affected: 12.8(3) Affected: 12.8(4) Affected: 12.8(5) Affected: 12.8(6) Affected: 12.8(7) Affected: 12.9(0) Affected: 12.9(1) Affected: 12.9(2) Affected: 12.9(3) Affected: 12.9(4) Affected: 12.9(5) Affected: 12.9(6) Affected: 8.6(1) Affected: 8.6(2) Affected: 8.6(3) Affected: 8.6(4) Affected: 8.6(5) Affected: 8.6(6) Affected: 8.6(7) Affected: 9.0(1) Affected: 9.0(2) Affected: 9.0(3) Affected: 9.0(4) Affected: 9.0(5) Affected: 9.1(0) Affected: 9.1(1) Affected: 9.1(2) Affected: 9.1(3) Affected: 9.1(4) Affected: 9.1(5) Affected: 9.2(0) Affected: 9.2(1) Affected: 9.2(2) Affected: 9.2(3) Affected: 9.2(4) Affected: 9.2(5) Affected: 9.2(6) Affected: 9.2(7) Affected: 9.3(1) Affected: 9.3(2) Affected: 9.5(0) Affected: 9.6(0) Affected: 9.6(1) Affected: 9.6(2) Affected: 9.6(3) Affected: 9.6(4) Affected: 9.7(0) Affected: 9.7(1) Affected: 9.7(2) Affected: 9.7(3) Affected: 9.7(4) Affected: 9.7(5) Affected: 9.7(6) Affected: 9.7(7) Affected: Jabber For Windows Affected: 14.0(0) Affected: 14.0(1) Affected: 14.0(2) Affected: 14.0(3) Affected: 14.0(4) Affected: 11.2(0) Affected: 11.2(1) Affected: 14.1(0) Affected: 14.1(1) Affected: 14.1(2) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:57.691Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "cisco-sa-jabber-xmpp-Ne9SCM",
"tags": [
"x_transferred"
],
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-jabber-xmpp-Ne9SCM"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-20917",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T14:03:09.028059Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:13:11.945Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Jabber",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "10.5(0)"
},
{
"status": "affected",
"version": "10.5(1)"
},
{
"status": "affected",
"version": "10.5(2)"
},
{
"status": "affected",
"version": "10.5(3)"
},
{
"status": "affected",
"version": "10.5(4)"
},
{
"status": "affected",
"version": "10.5(5)"
},
{
"status": "affected",
"version": "10.5(6)"
},
{
"status": "affected",
"version": "10.6(0)"
},
{
"status": "affected",
"version": "10.6(1)"
},
{
"status": "affected",
"version": "10.6(2)"
},
{
"status": "affected",
"version": "10.6(3)"
},
{
"status": "affected",
"version": "10.6(4)"
},
{
"status": "affected",
"version": "10.6(5)"
},
{
"status": "affected",
"version": "10.6(6)"
},
{
"status": "affected",
"version": "10.6(7)"
},
{
"status": "affected",
"version": "10.6(10)"
},
{
"status": "affected",
"version": "10.6(11)"
},
{
"status": "affected",
"version": "10.6(12)"
},
{
"status": "affected",
"version": "10.6(8)"
},
{
"status": "affected",
"version": "10.6(9)"
},
{
"status": "affected",
"version": "11.0(0)"
},
{
"status": "affected",
"version": "11.0(1)"
},
{
"status": "affected",
"version": "11.0(2)"
},
{
"status": "affected",
"version": "11.1(0)"
},
{
"status": "affected",
"version": "11.1(1)"
},
{
"status": "affected",
"version": "11.1(2)"
},
{
"status": "affected",
"version": "11.1(3)"
},
{
"status": "affected",
"version": "11.1(4)"
},
{
"status": "affected",
"version": "11.5(0)"
},
{
"status": "affected",
"version": "11.5(1)"
},
{
"status": "affected",
"version": "11.5(2)"
},
{
"status": "affected",
"version": "11.5(3)"
},
{
"status": "affected",
"version": "11.5(4)"
},
{
"status": "affected",
"version": "11.5(5)"
},
{
"status": "affected",
"version": "11.5(6)"
},
{
"status": "affected",
"version": "11.6(0)"
},
{
"status": "affected",
"version": "11.6(1)"
},
{
"status": "affected",
"version": "11.6(2)"
},
{
"status": "affected",
"version": "11.6(3)"
},
{
"status": "affected",
"version": "11.6(4)"
},
{
"status": "affected",
"version": "11.7(0)"
},
{
"status": "affected",
"version": "11.7(1)"
},
{
"status": "affected",
"version": "11.7(2)"
},
{
"status": "affected",
"version": "11.8(0)"
},
{
"status": "affected",
"version": "11.8(1)"
},
{
"status": "affected",
"version": "11.8(2)"
},
{
"status": "affected",
"version": "11.8(3)"
},
{
"status": "affected",
"version": "11.8(4)"
},
{
"status": "affected",
"version": "11.8(5)"
},
{
"status": "affected",
"version": "11.9(0)"
},
{
"status": "affected",
"version": "11.9(1)"
},
{
"status": "affected",
"version": "11.9(2)"
},
{
"status": "affected",
"version": "11.9(3)"
},
{
"status": "affected",
"version": "12.0(0)"
},
{
"status": "affected",
"version": "12.0(1)"
},
{
"status": "affected",
"version": "12.1(0)"
},
{
"status": "affected",
"version": "12.1(1)"
},
{
"status": "affected",
"version": "12.1(2)"
},
{
"status": "affected",
"version": "12.1(3)"
},
{
"status": "affected",
"version": "12.1(4)"
},
{
"status": "affected",
"version": "12.1(5)"
},
{
"status": "affected",
"version": "12.5(0)"
},
{
"status": "affected",
"version": "12.5(1)"
},
{
"status": "affected",
"version": "12.5(2)"
},
{
"status": "affected",
"version": "12.5(3)"
},
{
"status": "affected",
"version": "12.5(4)"
},
{
"status": "affected",
"version": "12.6(0)"
},
{
"status": "affected",
"version": "12.6(1)"
},
{
"status": "affected",
"version": "12.6(2)"
},
{
"status": "affected",
"version": "12.6(3)"
},
{
"status": "affected",
"version": "12.6(4)"
},
{
"status": "affected",
"version": "12.6(5)"
},
{
"status": "affected",
"version": "12.7(0)"
},
{
"status": "affected",
"version": "12.7(1)"
},
{
"status": "affected",
"version": "12.7(2)"
},
{
"status": "affected",
"version": "12.7(3)"
},
{
"status": "affected",
"version": "12.7(4)"
},
{
"status": "affected",
"version": "12.7(5)"
},
{
"status": "affected",
"version": "12.8(0)"
},
{
"status": "affected",
"version": "12.8(1)"
},
{
"status": "affected",
"version": "12.8(2)"
},
{
"status": "affected",
"version": "12.8(3)"
},
{
"status": "affected",
"version": "12.8(4)"
},
{
"status": "affected",
"version": "12.8(5)"
},
{
"status": "affected",
"version": "12.8(6)"
},
{
"status": "affected",
"version": "12.8(7)"
},
{
"status": "affected",
"version": "12.9(0)"
},
{
"status": "affected",
"version": "12.9(1)"
},
{
"status": "affected",
"version": "12.9(2)"
},
{
"status": "affected",
"version": "12.9(3)"
},
{
"status": "affected",
"version": "12.9(4)"
},
{
"status": "affected",
"version": "12.9(5)"
},
{
"status": "affected",
"version": "12.9(6)"
},
{
"status": "affected",
"version": "8.6(1)"
},
{
"status": "affected",
"version": "8.6(2)"
},
{
"status": "affected",
"version": "8.6(3)"
},
{
"status": "affected",
"version": "8.6(4)"
},
{
"status": "affected",
"version": "8.6(5)"
},
{
"status": "affected",
"version": "8.6(6)"
},
{
"status": "affected",
"version": "8.6(7)"
},
{
"status": "affected",
"version": "9.0(1)"
},
{
"status": "affected",
"version": "9.0(2)"
},
{
"status": "affected",
"version": "9.0(3)"
},
{
"status": "affected",
"version": "9.0(4)"
},
{
"status": "affected",
"version": "9.0(5)"
},
{
"status": "affected",
"version": "9.1(0)"
},
{
"status": "affected",
"version": "9.1(1)"
},
{
"status": "affected",
"version": "9.1(2)"
},
{
"status": "affected",
"version": "9.1(3)"
},
{
"status": "affected",
"version": "9.1(4)"
},
{
"status": "affected",
"version": "9.1(5)"
},
{
"status": "affected",
"version": "9.2(0)"
},
{
"status": "affected",
"version": "9.2(1)"
},
{
"status": "affected",
"version": "9.2(2)"
},
{
"status": "affected",
"version": "9.2(3)"
},
{
"status": "affected",
"version": "9.2(4)"
},
{
"status": "affected",
"version": "9.2(5)"
},
{
"status": "affected",
"version": "9.2(6)"
},
{
"status": "affected",
"version": "9.2(7)"
},
{
"status": "affected",
"version": "9.3(1)"
},
{
"status": "affected",
"version": "9.3(2)"
},
{
"status": "affected",
"version": "9.5(0)"
},
{
"status": "affected",
"version": "9.6(0)"
},
{
"status": "affected",
"version": "9.6(1)"
},
{
"status": "affected",
"version": "9.6(2)"
},
{
"status": "affected",
"version": "9.6(3)"
},
{
"status": "affected",
"version": "9.6(4)"
},
{
"status": "affected",
"version": "9.7(0)"
},
{
"status": "affected",
"version": "9.7(1)"
},
{
"status": "affected",
"version": "9.7(2)"
},
{
"status": "affected",
"version": "9.7(3)"
},
{
"status": "affected",
"version": "9.7(4)"
},
{
"status": "affected",
"version": "9.7(5)"
},
{
"status": "affected",
"version": "9.7(6)"
},
{
"status": "affected",
"version": "9.7(7)"
},
{
"status": "affected",
"version": "Jabber For Windows"
},
{
"status": "affected",
"version": "14.0(0)"
},
{
"status": "affected",
"version": "14.0(1)"
},
{
"status": "affected",
"version": "14.0(2)"
},
{
"status": "affected",
"version": "14.0(3)"
},
{
"status": "affected",
"version": "14.0(4)"
},
{
"status": "affected",
"version": "11.2(0)"
},
{
"status": "affected",
"version": "11.2(1)"
},
{
"status": "affected",
"version": "14.1(0)"
},
{
"status": "affected",
"version": "14.1(1)"
},
{
"status": "affected",
"version": "14.1(2)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Extensible Messaging and Presence Protocol (XMPP) message processing feature of Cisco Jabber could allow an authenticated, remote attacker to manipulate the content of XMPP messages that are used by the affected application.\r\n This vulnerability is due to the improper handling of nested XMPP messages within requests that are sent to the Cisco Jabber client software. An attacker could exploit this vulnerability by connecting to an XMPP messaging server and sending crafted XMPP messages to an affected Jabber client. A successful exploit could allow the attacker to manipulate the content of XMPP messages, possibly allowing the attacker to cause the Jabber client application to perform unsafe actions."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is aware that proof-of-concept exploit code is available for the vulnerability that is described in this advisory.\r\n\r\nThe Cisco PSIRT is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "cvssV3_1"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "cwe"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-25T16:57:12.844Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "cisco-sa-jabber-xmpp-Ne9SCM",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-jabber-xmpp-Ne9SCM"
}
],
"source": {
"advisory": "cisco-sa-jabber-xmpp-Ne9SCM",
"defects": [
"CSCwc24382"
],
"discovery": "EXTERNAL"
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2022-20917",
"datePublished": "2023-09-15T02:12:51.048Z",
"dateReserved": "2021-11-02T13:28:29.189Z",
"dateUpdated": "2024-09-25T14:13:11.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3866 (GCVE-0-2022-3866)
Vulnerability from cvelistv5 – Published: 2022-11-10 05:34 – Updated: 2025-05-01 19:05
VLAI
EPSS
VEX
Title
Nomad Workload Identity Token Can List Non-sensitive Metadata for Paths Under nomad/
Summary
HashiCorp Nomad and Nomad Enterprise 1.4.0 up to 1.4.1 workload identity token can list non-sensitive metadata for paths under nomad/ that belong to other jobs in the same namespace. Fixed in 1.4.2.
Severity
5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| HashiCorp | Nomad |
Affected:
1.4.0
Affected: 1.4.1 |
|
| HashiCorp | Nomad Enterprise |
Affected:
1.4.0
Affected: 1.4.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:20:58.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://discuss.hashicorp.com/t/hcsec-2022-25-nomad-s-workload-identity-token-can-list-non-sensitive-metadata-for-nomad-paths/46167"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3866",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T19:04:44.420595Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T19:05:00.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"64 bit",
"32 bit",
"x86",
"ARM",
"MacOS",
"Windows",
"Linux"
],
"product": "Nomad",
"repo": "https://github.com/hashicorp/nomad",
"vendor": "HashiCorp",
"versions": [
{
"status": "affected",
"version": "1.4.0"
},
{
"status": "affected",
"version": "1.4.1"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"64 bit",
"32 bit",
"x86",
"ARM",
"MacOS",
"Windows",
"Linux"
],
"product": "Nomad Enterprise",
"vendor": "HashiCorp",
"versions": [
{
"status": "affected",
"version": "1.4.0"
},
{
"status": "affected",
"version": "1.4.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HashiCorp Nomad and Nomad Enterprise 1.4.0 up to 1.4.1 workload identity token can list non-sensitive metadata for paths under nomad/ that belong to other jobs in the same namespace. Fixed in 1.4.2."
}
],
"value": "HashiCorp Nomad and Nomad Enterprise 1.4.0 up to 1.4.1 workload identity token can list non-sensitive metadata for paths under nomad/ that belong to other jobs in the same namespace. Fixed in 1.4.2."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-10T05:42:07.716Z",
"orgId": "67fedba0-ff2e-4543-ba5b-aa93e87718cc",
"shortName": "HashiCorp"
},
"references": [
{
"url": "https://discuss.hashicorp.com/t/hcsec-2022-25-nomad-s-workload-identity-token-can-list-non-sensitive-metadata-for-nomad-paths/46167"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Nomad Workload Identity Token Can List Non-sensitive Metadata for Paths Under nomad/"
}
},
"cveMetadata": {
"assignerOrgId": "67fedba0-ff2e-4543-ba5b-aa93e87718cc",
"assignerShortName": "HashiCorp",
"cveId": "CVE-2022-3866",
"datePublished": "2022-11-10T05:34:52.468Z",
"dateReserved": "2022-11-04T22:54:15.589Z",
"dateUpdated": "2025-05-01T19:05:00.374Z",
"requesterUserId": "5311d85b-fc2e-473d-9ddd-71031e52448b",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1467 (GCVE-0-2022-1467)
Vulnerability from cvelistv5 – Published: 2022-05-23 19:17 – Updated: 2025-04-16 16:19
VLAI
EPSS
VEX
Title
AVEVA InTouch Access Anywhere Exposure of Resource to Wrong Sphere
Summary
Windows OS can be configured to overlay a “language bar” on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS.
Severity
7.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.aveva.com/en/support-and-success/cybe… | x_refsource_MISC |
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| AVEVA | AVEVA InTouch Access Anywhere |
Affected:
all
|
|
| AVEVA | AVEVA Plant SCADA Access Anywhere |
Affected:
all
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:03:06.203Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.aveva.com/en/support-and-success/cyber-security-updates/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-130-05"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1467",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:51:57.240530Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:19:11.145Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AVEVA InTouch Access Anywhere",
"vendor": "AVEVA",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "AVEVA Plant SCADA Access Anywhere",
"vendor": "AVEVA",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Giovanni Delvecchio from Aceaspa reported this vulnerability to AVEVA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Windows OS can be configured to overlay a \u201clanguage bar\u201d on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-23T19:17:02.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.aveva.com/en/support-and-success/cyber-security-updates/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-130-05"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "AVEVA InTouch Access Anywhere Exposure of Resource to Wrong Sphere",
"workarounds": [
{
"lang": "en",
"value": "AVEVA recommends the following mitigations: \n\nDisable the Windows language bar on the server machine hosting InTouch Access Anywhere and Plant SCADA Access Anywhere applications unless it is required.\nCreate unique user accounts with minimal privileges dedicated only to remote access of InTouch Access Anywhere and Plant SCADA Access Anywhere applications.\nUtilize OS group policy objects (GPOs) to further restrict what those unique user accounts are allowed to do.\nRestrict access based on Microsoft\u2019s recommended block list.\nFor more information on this vulnerability, including security updates, please see security bulletin AVEVA-2022-001"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-1467",
"STATE": "PUBLIC",
"TITLE": "AVEVA InTouch Access Anywhere Exposure of Resource to Wrong Sphere"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AVEVA InTouch Access Anywhere",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "AVEVA"
},
{
"product": {
"product_data": [
{
"product_name": "AVEVA Plant SCADA Access Anywhere",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "AVEVA"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Giovanni Delvecchio from Aceaspa reported this vulnerability to AVEVA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Windows OS can be configured to overlay a \u201clanguage bar\u201d on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.aveva.com/en/support-and-success/cyber-security-updates/",
"refsource": "MISC",
"url": "https://www.aveva.com/en/support-and-success/cyber-security-updates/"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-130-05",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-130-05"
}
]
},
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "AVEVA recommends the following mitigations: \n\nDisable the Windows language bar on the server machine hosting InTouch Access Anywhere and Plant SCADA Access Anywhere applications unless it is required.\nCreate unique user accounts with minimal privileges dedicated only to remote access of InTouch Access Anywhere and Plant SCADA Access Anywhere applications.\nUtilize OS group policy objects (GPOs) to further restrict what those unique user accounts are allowed to do.\nRestrict access based on Microsoft\u2019s recommended block list.\nFor more information on this vulnerability, including security updates, please see security bulletin AVEVA-2022-001"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1467",
"datePublished": "2022-05-23T19:17:02.000Z",
"dateReserved": "2022-04-25T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:19:11.145Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-0815 (GCVE-0-2022-0815)
Vulnerability from cvelistv5 – Published: 2022-03-10 22:30 – Updated: 2024-08-02 23:40
VLAI
EPSS
VEX
Title
McAfee WebAdvisor - Extension Fingerprinting vulnerability
Summary
Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user’s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected.
Severity
6.5 (Medium)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://service.mcafee.com/?articleId=TS103273&pa… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| McAfee | McAfee WebAdvisor |
Affected:
unspecified , ≤ 8.1.0.1895
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:40:04.354Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "McAfee WebAdvisor",
"vendor": "McAfee",
"versions": [
{
"lessThanOrEqual": "8.1.0.1895",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-10T22:30:11.000Z",
"orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"shortName": "trellix"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
],
"source": {
"advisory": "TS103273",
"discovery": "EXTERNAL"
},
"title": "McAfee WebAdvisor - Extension Fingerprinting vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@mcafee.com",
"ID": "CVE-2022-0815",
"STATE": "PUBLIC",
"TITLE": "McAfee WebAdvisor - Extension Fingerprinting vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "McAfee WebAdvisor",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "8.1.0.1895"
}
]
}
}
]
},
"vendor_name": "McAfee"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view",
"refsource": "MISC",
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
]
},
"source": {
"advisory": "TS103273",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"assignerShortName": "trellix",
"cveId": "CVE-2022-0815",
"datePublished": "2022-03-10T22:30:11.000Z",
"dateReserved": "2022-03-01T00:00:00.000Z",
"dateUpdated": "2024-08-02T23:40:04.354Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44524 (GCVE-0-2021-44524)
Vulnerability from cvelistv5 – Published: 2021-12-14 12:07 – Updated: 2024-08-04 04:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts.
Severity
No CVSS data available.
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiPass integrated V2.76 |
Affected:
All versions
|
|
| Siemens | SiPass integrated V2.80 |
Affected:
All versions
|
|
| Siemens | SiPass integrated V2.85 |
Affected:
All versions
|
|
| Siemens | Siveillance Identity V1.5 |
Affected:
All versions
|
|
| Siemens | Siveillance Identity V1.6 |
Affected:
All versions < V1.6.284.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.779Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiPass integrated V2.76",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SiPass integrated V2.80",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SiPass integrated V2.85",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Siveillance Identity V1.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Siveillance Identity V1.6",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.6.284.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions \u003c V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-14T12:07:11.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-44524",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiPass integrated V2.76",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SiPass integrated V2.80",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SiPass integrated V2.85",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Siveillance Identity V1.5",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Siveillance Identity V1.6",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.6.284.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions \u003c V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44524",
"datePublished": "2021-12-14T12:07:11.000Z",
"dateReserved": "2021-12-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:25:16.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44523 (GCVE-0-2021-44523)
Vulnerability from cvelistv5 – Published: 2021-12-14 12:07 – Updated: 2024-08-04 04:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal activity feed database. This could allow an unauthenticated remote attacker to read, modify or delete activity feed entries.
Severity
No CVSS data available.
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiPass integrated V2.76 |
Affected:
All versions
|
|
| Siemens | SiPass integrated V2.80 |
Affected:
All versions
|
|
| Siemens | SiPass integrated V2.85 |
Affected:
All versions
|
|
| Siemens | Siveillance Identity V1.5 |
Affected:
All versions
|
|
| Siemens | Siveillance Identity V1.6 |
Affected:
All versions < V1.6.284.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.828Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiPass integrated V2.76",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SiPass integrated V2.80",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SiPass integrated V2.85",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Siveillance Identity V1.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Siveillance Identity V1.6",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.6.284.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions \u003c V1.6.284.0). Affected applications insufficiently limit the access to the internal activity feed database. This could allow an unauthenticated remote attacker to read, modify or delete activity feed entries."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-14T12:07:10.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-44523",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiPass integrated V2.76",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SiPass integrated V2.80",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SiPass integrated V2.85",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Siveillance Identity V1.5",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Siveillance Identity V1.6",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.6.284.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions \u003c V1.6.284.0). Affected applications insufficiently limit the access to the internal activity feed database. This could allow an unauthenticated remote attacker to read, modify or delete activity feed entries."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44523",
"datePublished": "2021-12-14T12:07:10.000Z",
"dateReserved": "2021-12-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:25:16.828Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.