CWE-494
Download of Code Without Integrity Check
The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.
CVE-2024-54126 (GCVE-0-2024-54126)
Vulnerability from cvelistv5 – Published: 2024-12-05 12:14 – Updated: 2024-12-05 16:37| URL | Tags |
|---|---|
| https://www.cert-in.org.in/s2cMainServlet?pageid=… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link | Archer C50 Wireless Router |
Affected:
<Archer C50(EU)_V4_ 240917
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tp-link:archer_c50_firmware:c50\\(eu\\)_v4_240917:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "archer_c50_firmware",
"vendor": "tp-link",
"versions": [
{
"status": "affected",
"version": "c50\\(eu\\)_v4_240917"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54126",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-05T15:56:14.433573Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-05T16:37:56.782Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Archer C50 Wireless Router",
"vendor": "TP-Link",
"versions": [
{
"status": "affected",
"version": "\u003cArcher C50(EU)_V4_ 240917"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported is reported by Khalid Markar, Amey Chavekar, Sushant Mane \u0026 Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device."
}
],
"value": "This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router\u2019s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-05T12:14:41.814Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0354"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to Archer C50(EU)_V4_ 240917\u003cbr\u003e\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\"\u003ehttps://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip\u003c/a\u003e \u003cbr\u003e"
}
],
"value": "Upgrade to Archer C50(EU)_V4_ 240917\n\n https://static.tp-link.com/upload/firmware/2024/202411/20241125/Archer%20C50(EU)_V4_240917.zip"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insufficient Integrity Verification Vulnerability in TP-Link Archer C50",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2024-54126",
"datePublished": "2024-12-05T12:14:41.814Z",
"dateReserved": "2024-11-29T11:09:33.863Z",
"dateUpdated": "2024-12-05T16:37:56.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10539 (GCVE-0-2025-10539)
Vulnerability from cvelistv5 – Published: 2026-04-28 07:52 – Updated: 2026-04-29 19:32| URL | Tags |
|---|---|
| https://r.sec-consult.com/desktime | third-party-advisory |
| https://desktime.com/download | patch |
| Vendor | Product | Version | |
|---|---|---|---|
| DeskTime | DeskTime Time Tracking App |
Affected:
0 , < 1.3.674
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-10539",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-28T14:09:20.701327Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-28T14:10:50.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://sec-consult.com/vulnerability-lab/advisory/missing-tls-certificate-validation-leading-to-rce-in-desktime-time-tracking-app/"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-04-29T19:32:10.480Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2026/Apr/20"
},
{
"url": "http://seclists.org/fulldisclosure/2026/Apr/21"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DeskTime Time Tracking App",
"vendor": "DeskTime",
"versions": [
{
"lessThan": "1.3.674",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Thorger Jansen, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Tobias Niemann, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Marius Renner, SEC Consult Vulnerability Lab"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cspan\u003eDue to improper TLS certificate validation in the DeskTime Time Tracking App before version 1.3.674, attackers who can position themselves in the network path between the client and the DeskTime update servers can return a malicious executable in response to an update request. This allows the attacker to achieve user-level remote code execution on the affected client.\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "Due to improper TLS certificate validation in the DeskTime Time Tracking App before version 1.3.674, attackers who can position themselves in the network path between the client and the DeskTime update servers can return a malicious executable in response to an update request. This allows the attacker to achieve user-level remote code execution on the affected client."
}
],
"impacts": [
{
"capecId": "CAPEC-187",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-187 Malicious Automated Software Update via Redirection"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper certificate validation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-296",
"description": "CWE-296 Improper following of a certificate\u0027s chain of trust",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of code without integrity check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-28T07:52:23.279Z",
"orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"shortName": "SEC-VLab"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://r.sec-consult.com/desktime"
},
{
"tags": [
"patch"
],
"url": "https://desktime.com/download"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vendor provides a patched version v1.3.674 which can be obtained from: https://desktime.com/download\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "The vendor provides a patched version v1.3.674 which can be obtained from: https://desktime.com/download"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Improper TLS Certificate Validation RCE via Malicious Update in DeskTime Time Tracking App",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"assignerShortName": "SEC-VLab",
"cveId": "CVE-2025-10539",
"datePublished": "2026-04-28T07:52:23.279Z",
"dateReserved": "2025-09-16T07:39:47.680Z",
"dateUpdated": "2026-04-29T19:32:10.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-1058 (GCVE-0-2025-1058)
Vulnerability from cvelistv5 – Published: 2025-02-13 05:45 – Updated: 2025-02-13 16:30- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | ASCO 5310 Single-Channel Remote Annunciator |
Affected:
All versions
|
|
| Schneider Electric | ASCO 5350 Eight Channel Remote Annunciator |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1058",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-13T16:30:14.818140Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T16:30:26.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ASCO 5310 Single-Channel Remote Annunciator",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ASCO 5350 Eight Channel Remote Annunciator",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-494: Download of Code Without Integrity Check vulnerability exists that could render the device\ninoperable when malicious firmware is downloaded.\n\n\u003cbr\u003e"
}
],
"value": "CWE-494: Download of Code Without Integrity Check vulnerability exists that could render the device\ninoperable when malicious firmware is downloaded."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T05:45:05.513Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=sevd-2025-042-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-042-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-1058",
"datePublished": "2025-02-13T05:45:05.513Z",
"dateReserved": "2025-02-05T13:07:50.701Z",
"dateUpdated": "2025-02-13T16:30:26.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-11182 (GCVE-0-2025-11182)
Vulnerability from cvelistv5 – Published: 2025-10-02 05:15 – Updated: 2025-10-02 15:54| Vendor | Product | Version | |
|---|---|---|---|
| GTONE | ChangeFlow |
Affected:
All versions , ≤ v9.0.1.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11182",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-02T15:28:55.312055Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-02T15:54:05.142Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ChangeFlow",
"vendor": "GTONE",
"versions": [
{
"lessThanOrEqual": "v9.0.1.1",
"status": "affected",
"version": "All versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "arang(\uc720\uc7ac\uc6b1, Jaewook You)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Download of Code Without Integrity Check vulnerability in GTONE ChangeFlow allows Path Traversal.\u003cp\u003eThis issue affects ChangeFlow: All versions to v9.0.1.1.\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Download of Code Without Integrity Check vulnerability in GTONE ChangeFlow allows Path Traversal.This issue affects ChangeFlow: All versions to v9.0.1.1."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-02T05:15:06.469Z",
"orgId": "09832df1-09c1-45b4-8a85-16c601d30feb",
"shortName": "FSI"
},
"references": [
{
"url": "http://www.gtone.co.kr/kr/application-lifecycle-management.php"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "File Download in GTONE ChangeFlow",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "09832df1-09c1-45b4-8a85-16c601d30feb",
"assignerShortName": "FSI",
"cveId": "CVE-2025-11182",
"datePublished": "2025-10-02T05:15:06.469Z",
"dateReserved": "2025-09-30T05:55:50.626Z",
"dateUpdated": "2025-10-02T15:54:05.142Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-11493 (GCVE-0-2025-11493)
Vulnerability from cvelistv5 – Published: 2025-10-16 19:00 – Updated: 2026-02-26 16:57- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| ConnectWise | Automate |
Affected:
All versions prior to 2025.9
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11493",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-17T03:55:32.566730Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T16:57:24.641Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate",
"vendor": "ConnectWise",
"versions": [
{
"status": "affected",
"version": "All versions prior to 2025.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The ConnectWise Automate Agent does not fully verify the authenticity of files downloaded from the server, such as updates, dependencies, and integrations. This creates a risk where an on-path attacker could perform a man-in-the-middle attack and substitute malicious files for legitimate ones by impersonating a legitimate server. This risk is mitigated when HTTPS is enforced and is related to CVE-2025-11492."
}
],
"value": "The ConnectWise Automate Agent does not fully verify the authenticity of files downloaded from the server, such as updates, dependencies, and integrations. This creates a risk where an on-path attacker could perform a man-in-the-middle attack and substitute malicious files for legitimate ones by impersonating a legitimate server. This risk is mitigated when HTTPS is enforced and is related to CVE-2025-11492."
}
],
"impacts": [
{
"capecId": "CAPEC-186",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-186 Malicious Software Update"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T19:00:39.119Z",
"orgId": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"shortName": "ConnectWise"
},
"references": [
{
"url": "https://www.connectwise.com/company/trust/security-bulletins/connectwise-automate-2025.9-security-fix"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cb\u003eCloud:\u0026nbsp;\u003c/b\u003eCloud instances have already been updated to the latest\nAutomate release. \u0026nbsp;\u0026nbsp;\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003cb\u003eOn-premise\u003c/b\u003e: Apply the 2025.9\nrelease.\u003c/p\u003e\n\n\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "Cloud:\u00a0Cloud instances have already been updated to the latest\nAutomate release. \u00a0\u00a0\n\n\n\n\n\n\n\nOn-premise: Apply the 2025.9\nrelease."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Self-Update Verification Mechanism Process in ConnectWise Automate",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"assignerShortName": "ConnectWise",
"cveId": "CVE-2025-11493",
"datePublished": "2025-10-16T19:00:39.119Z",
"dateReserved": "2025-10-08T11:26:01.814Z",
"dateUpdated": "2026-02-26T16:57:24.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14265 (GCVE-0-2025-14265)
Vulnerability from cvelistv5 – Published: 2025-12-11 14:21 – Updated: 2026-02-26 16:21- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| ConnectWise | ScreenConnect |
Affected:
All versions prior to 2025.8
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14265",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-12T04:55:51.377077Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T16:21:03.963Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web Application Server"
],
"product": "ScreenConnect",
"vendor": "ConnectWise",
"versions": [
{
"status": "affected",
"version": "All versions prior to 2025.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Paul Whiting (Ultraviolet Cyber)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In versions of ScreenConnect\u2122 prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed.\u003cbr\u003e"
}
],
"value": "In versions of ScreenConnect\u2122 prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed."
}
],
"impacts": [
{
"capecId": "CAPEC-137",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-137 Parameter Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-11T21:19:13.087Z",
"orgId": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"shortName": "ConnectWise"
},
"references": [
{
"url": "https://www.connectwise.com/company/trust/security-bulletins/screenconnect-2025.8-security-patch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cbr\u003e\u003cp\u003e\u003cb\u003eCloud:\u0026nbsp;\u003c/b\u003eNo action is required. ScreenConnect servers hosted in\n\u201cscreenconnect.com\u201d cloud (standalone and Automate/RMM integrated) or\n\u201chostedrmm.com\u201d for Automate partners have been updated to remediate the\nissue.\u202f\u0026nbsp;\u0026nbsp;\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003cb\u003eOn-prem:\u003c/b\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003cb\u003eScreenConnect\u003c/b\u003e \u003cb\u003ePartners:\u0026nbsp;\u003c/b\u003e\u003c/a\u003ePlease upgrade to ScreenConnect version 25.8 and update\nyour guest clients to the same version. Visit \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://order.screenconnect.com/Create-Order\"\u003eDownload\n| ScreenConnect\u003c/a\u003e page to download and apply the update \u003ci\u003e(access\nrequires a valid on-premises license)\u003c/i\u003e.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003cb\u003eAutomate On-Prem Partners with\nScreenConnect Integration\u003c/b\u003e:\u0026nbsp;\u003c/a\u003e\n\nPartners using an on-premises ScreenConnect installation integrated with Automate must ensure that the Automate ScreenConnect Extension is updated to version 4.4.0.16 before upgrading the ScreenConnect server to version 25.8. Once confirmed, visit the \n\n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://docs.connectwise.com/ConnectWise_Automate_Documentation/Automate_Product_Updates\"\u003eAutomate Product Updates\u003c/a\u003e \n\n page to download and apply the ScreenConnect 25.8 update.\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n\n\n\n\n\u003cdiv\u003e\n\n\n\n\n\n\u003cdiv\u003e\n\n\n\n\u003cp\u003e\u003cbr\u003e\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Cloud:\u00a0No action is required. ScreenConnect servers hosted in\n\u201cscreenconnect.com\u201d cloud (standalone and Automate/RMM integrated) or\n\u201chostedrmm.com\u201d for Automate partners have been updated to remediate the\nissue.\u202f\u00a0\u00a0\n\n\n\n\n\n\n\nOn-prem:\n\n\n\n\n\n * ScreenConnect Partners:\u00a0Please upgrade to ScreenConnect version 25.8 and update\nyour guest clients to the same version. Visit Download\n| ScreenConnect page to download and apply the update (access\nrequires a valid on-premises license).\u00a0\n * Automate On-Prem Partners with\nScreenConnect Integration:\u00a0\n\nPartners using an on-premises ScreenConnect installation integrated with Automate must ensure that the Automate ScreenConnect Extension is updated to version 4.4.0.16 before upgrading the ScreenConnect server to version 25.8. Once confirmed, visit the \n\n Automate Product Updates https://docs.connectwise.com/ConnectWise_Automate_Documentation/Automate_Product_Updates \n\n page to download and apply the ScreenConnect 25.8 update."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper server-side validation in ScreenConnect extension framework",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
"assignerShortName": "ConnectWise",
"cveId": "CVE-2025-14265",
"datePublished": "2025-12-11T14:21:53.234Z",
"dateReserved": "2025-12-08T12:25:20.291Z",
"dateUpdated": "2026-02-26T16:21:03.963Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15556 (GCVE-0-2025-15556)
Vulnerability from cvelistv5 – Published: 2026-02-03 00:50 – Updated: 2026-03-05 01:29 X_Known Exploited Vulnerability- CWE-494 - Download of Code Without Integrity Check
| URL | Tags |
|---|---|
| https://community.notepad-plus-plus.org/topic/272… | release-notespatch |
| https://notepad-plus-plus.org/news/hijacked-incid… | vendor-advisory |
| https://github.com/notepad-plus-plus/notepad-plus… | patch |
| https://github.com/notepad-plus-plus/wingup/commi… | patch |
| https://www.vulncheck.com/advisories/notepad-plus… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| notepad-plus-plus | notepad-plus-plus |
Affected:
0 , < 8.8.9
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15556",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-13T04:56:27.295409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2026-02-12",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-15556"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T15:04:30.781Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-15556"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://notepad-plus-plus.org//news//clarification-security-incident/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-12T00:00:00.000Z",
"value": "CVE-2025-15556 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "notepad-plus-plus",
"repo": "https://github.com/notepad-plus-plus",
"vendor": "notepad-plus-plus",
"versions": [
{
"lessThan": "8.8.9",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:notepad_plus_plus:notepad\\+\\+:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.8.9",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Notepad++ versions prior to 8.8.9, when using the WinGUp updater, contain an update integrity verification vulnerability where downloaded update metadata and installers are not cryptographically verified. An attacker able to intercept or redirect update traffic can cause the updater to download and execute an attacker-controlled installer, resulting in arbitrary code execution with the privileges of the user."
}
],
"value": "Notepad++ versions prior to 8.8.9, when using the WinGUp updater, contain an update integrity verification vulnerability where downloaded update metadata and installers are not cryptographically verified. An attacker able to intercept or redirect update traffic can cause the updater to download and execute an attacker-controlled installer, resulting in arbitrary code execution with the privileges of the user."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-05T01:29:51.538Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"release-notes",
"patch"
],
"url": "https://community.notepad-plus-plus.org/topic/27298/notepad-v8-8-9-vulnerability-fix"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://notepad-plus-plus.org/news/hijacked-incident-info-update/"
},
{
"tags": [
"patch"
],
"url": "https://github.com/notepad-plus-plus/notepad-plus-plus/commit/bcf2aa68ef414338d717e20e059459570ed6c5ab"
},
{
"tags": [
"patch"
],
"url": "https://github.com/notepad-plus-plus/wingup/commit/ce0037549995ed0396cc363544d14b3425614fdb"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/notepad-plus-plus-wingup-updater-lacks-update-integrity-verification"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"timeline": [
{
"lang": "en",
"time": "2025-12-09T17:41:00.000Z",
"value": "Vulnerability is publicly disclosed"
},
{
"lang": "en",
"time": "2026-02-02T17:00:00.000Z",
"value": "Announcement of exploitation in the wild"
}
],
"title": "Notepad++ \u003c 8.8.9 WinGUp Updater Lacks Update Integrity Verification",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15556",
"datePublished": "2026-02-03T00:50:29.516Z",
"dateReserved": "2026-02-02T22:25:12.781Z",
"dateUpdated": "2026-03-05T01:29:51.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15575 (GCVE-0-2025-15575)
Vulnerability from cvelistv5 – Published: 2026-02-12 10:51 – Updated: 2026-02-12 15:13- CWE-494 - Download of Code Without Integrity Check
| URL | Tags |
|---|---|
| https://r.sec-consult.com/solax |
| Vendor | Product | Version | |
|---|---|---|---|
| SolaX Power | Pocket WiFi 3.0 |
Affected:
<3.022.03
|
|
| SolaX Power | Pocket WiFi+LAN |
Affected:
<1.009.02
|
|
| SolaX Power | Pocket WiFi+4GM |
Affected:
<1.005.05
|
|
| SolaX Power | Pocket WiFi+LAN 2.0 |
Affected:
<006.06
|
|
| SolaX Power | Pocket WiFi 4.0 |
Affected:
<003.03
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-15575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-12T15:13:42.470930Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-12T15:13:52.412Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Pocket WiFi 3.0",
"vendor": "SolaX Power",
"versions": [
{
"status": "affected",
"version": "\u003c3.022.03"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pocket WiFi+LAN",
"vendor": "SolaX Power",
"versions": [
{
"status": "affected",
"version": "\u003c1.009.02"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pocket WiFi+4GM",
"vendor": "SolaX Power",
"versions": [
{
"status": "affected",
"version": "\u003c1.005.05"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pocket WiFi+LAN 2.0",
"vendor": "SolaX Power",
"versions": [
{
"status": "affected",
"version": "\u003c006.06"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pocket WiFi 4.0",
"vendor": "SolaX Power",
"versions": [
{
"status": "affected",
"version": "\u003c003.03"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stefan Viehb\u00f6ck, SEC Consult Vulnerability Lab"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The firmware update functionality does not verify the authenticity of the supplied firmware update files. This allows attackers to flash malicious firmware update files on the device.\u0026nbsp;Initial analysis of the firmware update functionality does not show any cryptographic checks (e.g. digital signature checks) on the supplied firmware update files. Furthermore, ESP32 security features such as secure boot are not used.\u003cbr\u003e"
}
],
"value": "The firmware update functionality does not verify the authenticity of the supplied firmware update files. This allows attackers to flash malicious firmware update files on the device.\u00a0Initial analysis of the firmware update functionality does not show any cryptographic checks (e.g. digital signature checks) on the supplied firmware update files. Furthermore, ESP32 security features such as secure boot are not used."
}
],
"impacts": [
{
"capecId": "CAPEC-439",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-439 Manipulation During Distribution"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-12T10:57:44.013Z",
"orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"shortName": "SEC-VLab"
},
"references": [
{
"url": "https://r.sec-consult.com/solax"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\u003cbr\u003e\u003cbr\u003eAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\u003cbr\u003e1. Pocket WiFi 3.0 \u2013 (3.022.03)\u003cbr\u003e2. Pocket WiFi+LAN \u2013 (1.009.02)\u003cbr\u003e3. Pocket WiFi+4GM \u2013 (1.005.05)\u003cbr\u003e4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\u003cbr\u003e5. Pocket WiFi 4.0 \u2013 (003.03)\u003cbr\u003e\u003cbr\u003eThe vendor provided the following further information regarding EV Charger and Adapter Box:\u003cbr\u003e1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\u003cbr\u003e2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature.\u003cbr\u003e"
}
],
"value": "The vendor provides patches for the affected Pocket models which can be obtained throw their customer\u0027s Solax Cloud account and using the Pocket firmware upgrade function there.\n\nAs of February 10, 2026, the firmware versions for each affected Pocket model are as follows according to the vendor:\n1. Pocket WiFi 3.0 \u2013 (3.022.03)\n2. Pocket WiFi+LAN \u2013 (1.009.02)\n3. Pocket WiFi+4GM \u2013 (1.005.05)\n4. Pocket WiFi+LAN 2.0 \u2013 (006.06)\n5. Pocket WiFi 4.0 \u2013 (003.03)\n\nThe vendor provided the following further information regarding EV Charger and Adapter Box:\n1. EV Charger: The WiFi module firmware supports digital signature, but only one-way authentication is implemented.\n2. Adapter Box: The WiFi module firmware supports two-way authentication and digital signature."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Missing Firmware Authenticity Checks in Solax Power Pocket WiFi models",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"assignerShortName": "SEC-VLab",
"cveId": "CVE-2025-15575",
"datePublished": "2026-02-12T10:51:44.650Z",
"dateReserved": "2026-02-09T09:43:52.314Z",
"dateUpdated": "2026-02-12T15:13:52.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-27593 (GCVE-0-2025-27593)
Vulnerability from cvelistv5 – Published: 2025-03-14 12:46 – Updated: 2025-03-14 13:36- CWE-494 - Download of Code Without Integrity Check
| URL | Tags |
|---|---|
| https://sick.com/psirt | x_SICK PSIRT Website |
| https://cdn.sick.com/media/docs/1/11/411/Special_… | x_SICK Operating Guidelines |
| https://www.cisa.gov/resources-tools/resources/ic… | x_ICS-CERT recommended practices on Industrial Security |
| https://www.first.org/cvss/calculator/3.1 | x_CVSS v3.1 Calculator |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisory |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisoryx_csaf |
| https://github.security.telekom.com/2025/03/multi… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | SICK DL100-2xxxxxxx |
Affected:
all versions
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27593",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-14T13:36:43.451142Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T13:36:49.059Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK DL100-2xxxxxxx",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Leonard Lewedei"
}
],
"datePublic": "2025-03-14T12:32:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The product can be used to distribute malicious code using SDD Device Drivers due to missing download verification checks, leading to code execution on target systems."
}
],
"value": "The product can be used to distribute malicious code using SDD Device Drivers due to missing download verification checks, leading to code execution on target systems."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T12:46:58.946Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_SICK PSIRT Website"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"x_SICK Operating Guidelines"
],
"url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"tags": [
"x_CVSS v3.1 Calculator"
],
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0004.pdf"
},
{
"tags": [
"vendor-advisory",
"x_csaf"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0004.json"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://github.security.telekom.com/2025/03/multiple-vulnerabilities-in-sick-dl100.html"
}
],
"source": {
"advisory": "sca-2025-0004",
"discovery": "EXTERNAL"
},
"title": "RCE due to Device Driver",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.\u003cbr\u003e"
}
],
"value": "Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2025-27593",
"datePublished": "2025-03-14T12:46:58.946Z",
"dateReserved": "2025-03-03T13:27:07.018Z",
"dateUpdated": "2025-03-14T13:36:49.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30199 (GCVE-0-2025-30199)
Vulnerability from cvelistv5 – Published: 2025-09-05 17:45 – Updated: 2025-09-08 18:21- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|
| ECOVACS | DEEBOT T20 Series |
Affected:
*
|
|
| ECOVACS | DEEBOT T10 Series |
Affected:
*
|
|
| ECOVACS | DEEBOT T30 Series |
Affected:
*
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:20:48.723390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:21:06.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:09:57.869806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:10:36.047Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30199"
}
],
"title": "ECOVACS Vacuum and Base Station accept unsigned firmware"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30199",
"datePublished": "2025-09-05T17:45:07.227Z",
"dateReserved": "2025-03-18T15:53:08.738Z",
"dateUpdated": "2025-09-08T18:21:06.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-42
Phase: Implementation
Description:
- Perform proper forward and reverse DNS lookups to detect DNS spoofing.
Mitigation
Phases: Architecture and Design, Operation
Description:
- Encrypt the code with a reliable encryption scheme before transmitting.
- This will only be a partial solution, since it will not detect DNS spoofing and it will not prevent your code from being modified on the hosting site.
Mitigation ID: MIT-4
Phase: Architecture and Design
Strategy: Libraries or Frameworks
Description:
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid [REF-1482].
- Speficially, it may be helpful to use tools or frameworks to perform integrity checking on the transmitted code.
- When providing the code that is to be downloaded, such as for automatic updates of the software, then use cryptographic signatures for the code and modify the download clients to verify the signatures. Ensure that the implementation does not contain CWE-295, CWE-320, CWE-347, and related weaknesses.
- Use code signing technologies such as Authenticode. See references [REF-454] [REF-455] [REF-456].
Mitigation ID: MIT-17
Phases: Architecture and Design, Operation
Strategy: Environment Hardening
Description:
- Run your code using the lowest privileges that are required to accomplish the necessary tasks [REF-76]. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.
Mitigation ID: MIT-22
Phases: Architecture and Design, Operation
Strategy: Sandbox or Jail
Description:
- Run the code in a "jail" or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which files can be accessed in a particular directory or which commands can be executed by the software.
- OS-level examples include the Unix chroot jail, AppArmor, and SELinux. In general, managed code may provide some protection. For example, java.io.FilePermission in the Java SecurityManager allows the software to specify restrictions on file operations.
- This may not be a feasible solution, and it only limits the impact to the operating system; the rest of the application may still be subject to compromise.
- Be careful to avoid CWE-243 and other weaknesses related to jails.
CAPEC-184: Software Integrity Attack
An attacker initiates a series of events designed to cause a user, program, server, or device to perform actions which undermine the integrity of software code, device data structures, or device firmware, achieving the modification of the target's integrity to achieve an insecure state.
CAPEC-185: Malicious Software Download
An attacker uses deceptive methods to cause a user or an automated process to download and install dangerous code that originates from an attacker controlled source. There are several variations to this strategy of attack.
CAPEC-186: Malicious Software Update
An adversary uses deceptive methods to cause a user or an automated process to download and install dangerous code believed to be a valid update that originates from an adversary controlled source.
CAPEC-187: Malicious Automated Software Update via Redirection
An attacker exploits two layers of weaknesses in server or client software for automated update mechanisms to undermine the integrity of the target code-base. The first weakness involves a failure to properly authenticate a server as a source of update or patch content. This type of weakness typically results from authentication mechanisms which can be defeated, allowing a hostile server to satisfy the criteria that establish a trust relationship. The second weakness is a systemic failure to validate the identity and integrity of code downloaded from a remote location, hence the inability to distinguish malicious code from a legitimate update.
CAPEC-533: Malicious Manual Software Update
An attacker introduces malicious code to the victim's system by altering the payload of a software update, allowing for additional compromise or site disruption at the victim location. These manual, or user-assisted attacks, vary from requiring the user to download and run an executable, to as streamlined as tricking the user to click a URL. Attacks which aim at penetrating a specific network infrastructure often rely upon secondary attack methods to achieve the desired impact. Spamming, for example, is a common method employed as an secondary attack vector. Thus the attacker has in their arsenal a choice of initial attack vectors ranging from traditional SMTP/POP/IMAP spamming and its varieties, to web-application mechanisms which commonly implement both chat and rich HTML messaging within the user interface.
CAPEC-538: Open-Source Library Manipulation
Adversaries implant malicious code in open source software (OSS) libraries to have it widely distributed, as OSS is commonly downloaded by developers and other users to incorporate into software development projects. The adversary can have a particular system in mind to target, or the implantation can be the first stage of follow-on attacks on many systems.
CAPEC-657: Malicious Automated Software Update via Spoofing
An attackers uses identify or content spoofing to trick a client into performing an automated software update from a malicious source. A malicious automated software update that leverages spoofing can include content or identity spoofing as well as protocol spoofing. Content or identity spoofing attacks can trigger updates in software by embedding scripted mechanisms within a malicious web page, which masquerades as a legitimate update source. Scripting mechanisms communicate with software components and trigger updates from locations specified by the attackers' server. The result is the client believing there is a legitimate software update available but instead downloading a malicious update from the attacker.
CAPEC-662: Adversary in the Browser (AiTB)
An adversary exploits security vulnerabilities or inherent functionalities of a web browser, in order to manipulate traffic between two endpoints.
CAPEC-691: Spoof Open-Source Software Metadata
An adversary spoofs open-source software metadata in an attempt to masquerade malicious software as popular, maintained, and trusted.
CAPEC-692: Spoof Version Control System Commit Metadata
An adversary spoofs metadata pertaining to a Version Control System (VCS) (e.g., Git) repository's commits to deceive users into believing that the maliciously provided software is frequently maintained and originates from a trusted source.
CAPEC-693: StarJacking
An adversary spoofs software popularity metadata to deceive users into believing that a maliciously provided package is widely used and originates from a trusted source.
CAPEC-695: Repo Jacking
An adversary takes advantage of the redirect property of directly linked Version Control System (VCS) repositories to trick users into incorporating malicious code into their applications.