CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

CVE-2024-49557 (GCVE-0-2024-49557)

Vulnerability from cvelistv5 – Published: 2024-11-12 03:26 – Updated: 2024-11-12 15:20
VLAI
Summary
Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric OS10 Software Affected: 10.5.6.x
Affected: 10.5.5.x
Affected: 10.5.4.x
Create a notification for this product.
dell smartfabric_os10 Affected: 10.5.6.x
Affected: 10.5.5.x
Affected: 10.5.4.x
    cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-11-11 06:30
Credits
Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting these issues.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "smartfabric_os10",
            "vendor": "dell",
            "versions": [
              {
                "status": "affected",
                "version": "10.5.6.x"
              },
              {
                "status": "affected",
                "version": "10.5.5.x"
              },
              {
                "status": "affected",
                "version": "10.5.4.x"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-49557",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T15:20:08.921557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T15:20:55.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric OS10 Software",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.6.x"
            },
            {
              "status": "affected",
              "version": "10.5.5.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting these issues."
        }
      ],
      "datePublic": "2024-11-11T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "value": "Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T03:26:43.287Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000247217/dsa-2024-425-security-update-for-dell-networking-os10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-49557",
    "datePublished": "2024-11-12T03:26:43.287Z",
    "dateReserved": "2024-10-16T05:04:26.794Z",
    "dateUpdated": "2024-11-12T15:20:55.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-49560 (GCVE-0-2024-49560)

Vulnerability from cvelistv5 – Published: 2024-11-12 03:17 – Updated: 2024-11-12 15:25
VLAI
Summary
Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric OS10 Software Affected: 10.5.6.x
Affected: 10.5.5.x
Affected: 10.5.4.x
Create a notification for this product.
dell smartfabric_os10 Affected: 10.5.6.x
Affected: 10.5.5.x
Affected: 10.5.4.x
    cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-11-11 06:30
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smartfabric_os10",
            "vendor": "dell",
            "versions": [
              {
                "status": "affected",
                "version": "10.5.6.x"
              },
              {
                "status": "affected",
                "version": "10.5.5.x"
              },
              {
                "status": "affected",
                "version": "10.5.4.x"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-49560",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T15:24:31.278843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T15:25:33.106Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric OS10 Software",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.6.x"
            },
            {
              "status": "affected",
              "version": "10.5.5.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2024-11-11T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T03:17:10.537Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000247217/dsa-2024-425-security-update-for-dell-networking-os10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-49560",
    "datePublished": "2024-11-12T03:17:10.537Z",
    "dateReserved": "2024-10-16T05:04:26.795Z",
    "dateUpdated": "2024-11-12T15:25:33.106Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4999 (GCVE-0-2024-4999)

Vulnerability from cvelistv5 – Published: 2024-05-16 12:14 – Updated: 2024-08-01 20:55
VLAI
Title
Ligowave Unity/Pro/Mimo/APC Arbitrary Command Injection
Summary
A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Ligowave UNITY Affected: 0 , ≤ 6.95-2 (semver)
Create a notification for this product.
Ligowave PRO Affected: 0 , ≤ 6.95-1.rt3883 (semver)
Create a notification for this product.
Ligowave MIMO Affected: 0 , ≤ 6.95-1.rt2880 (semver)
Create a notification for this product.
Ligowave APC Propeller Affected: 0 , ≤ 2-5.95-4.rt3352 (semver)
Create a notification for this product.
ligowave unity Affected: 6.95-2
    cpe:2.3:h:ligowave:unity:6.95-2:*:*:*:*:*:*:*
Create a notification for this product.
ligowave pro Affected: 6.95-1.rt3883
    cpe:2.3:h:ligowave:pro:6.95-1.rt3883:*:*:*:*:*:*:*
Create a notification for this product.
ligowave mimo Affected: 6.95-1.rt2880
    cpe:2.3:h:ligowave:mimo:6.95-1.rt2880:*:*:*:*:*:*:*
Create a notification for this product.
ligowave apc_propeller Affected: 2-5.95-4.rt3352
    cpe:2.3:h:ligowave:apc_propeller:2-5.95-4.rt3352:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Quentin Kaiser from ONEKEY Research Labs
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:ligowave:unity:6.95-2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unity",
            "vendor": "ligowave",
            "versions": [
              {
                "status": "affected",
                "version": "6.95-2"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:ligowave:pro:6.95-1.rt3883:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "pro",
            "vendor": "ligowave",
            "versions": [
              {
                "status": "affected",
                "version": "6.95-1.rt3883"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:ligowave:mimo:6.95-1.rt2880:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mimo",
            "vendor": "ligowave",
            "versions": [
              {
                "status": "affected",
                "version": "6.95-1.rt2880"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:ligowave:apc_propeller:2-5.95-4.rt3352:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "apc_propeller",
            "vendor": "ligowave",
            "versions": [
              {
                "status": "affected",
                "version": "2-5.95-4.rt3352"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4999",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-16T15:17:05.688626Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:18.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:55:10.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://onekey.com/blog/security-advisory-remote-code-execution-in-ligowave-devices/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UNITY",
          "vendor": "Ligowave",
          "versions": [
            {
              "lessThanOrEqual": "6.95-2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PRO",
          "vendor": "Ligowave",
          "versions": [
            {
              "lessThanOrEqual": "6.95-1.rt3883",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MIMO",
          "vendor": "Ligowave",
          "versions": [
            {
              "lessThanOrEqual": "6.95-1.rt2880",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "APC Propeller",
          "vendor": "Ligowave",
          "versions": [
            {
              "lessThanOrEqual": "2-5.95-4.rt3352",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Quentin Kaiser from ONEKEY Research Labs"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote\u0026nbsp;attacker to execute arbitrary commands with elevated privileges.\u003cp\u003eThis issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352.\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote\u00a0attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "HIGH",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-16T12:17:49.310Z",
        "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "shortName": "ONEKEY"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://onekey.com/blog/security-advisory-remote-code-execution-in-ligowave-devices/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Ligowave Unity/Pro/Mimo/APC Arbitrary Command Injection",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This product being EOL, Ligowave will not patch the vulnerability. If replacement of the EOL device is not possible, ensure access to the administration interface is restricted to administration network zones only, to reduce likelihood of exploitation."
            }
          ],
          "value": "This product being EOL, Ligowave will not patch the vulnerability. If replacement of the EOL device is not possible, ensure access to the administration interface is restricted to administration network zones only, to reduce likelihood of exploitation."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
    "assignerShortName": "ONEKEY",
    "cveId": "CVE-2024-4999",
    "datePublished": "2024-05-16T12:14:51.671Z",
    "dateReserved": "2024-05-16T12:06:27.762Z",
    "dateUpdated": "2024-08-01T20:55:10.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5023 (GCVE-0-2024-5023)

Vulnerability from cvelistv5 – Published: 2024-05-16 18:05 – Updated: 2024-08-01 21:03
VLAI
Title
Arbitrary File Read Vulnerability in ConsoleMe via Limited Git command RCE
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Netflix ConsoleMe Affected: 0 , < 1.4.0 (git)
Create a notification for this product.
netflix consoleme Affected: 0 , < 1.4.0 (custom)
    cpe:2.3:a:netflix:consoleme:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-05-16 18:01
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:netflix:consoleme:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "consoleme",
            "vendor": "netflix",
            "versions": [
              {
                "lessThan": "1.4.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5023",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-16T19:41:24.820927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T19:54:20.543Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:03:09.642Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/Netflix/security-bulletins/blob/master/advisories/nflx-2024-002.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ConsoleMe",
          "repo": "https://github.com/Netflix/consoleme/",
          "vendor": "Netflix",
          "versions": [
            {
              "lessThan": "1.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "git"
            }
          ]
        }
      ],
      "datePublic": "2024-05-16T18:01:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Netflix ConsoleMe allows Command Injection.\u003cp\u003eThis issue affects ConsoleMe: before 1.4.0.\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-16T18:23:48.028Z",
        "orgId": "ea63fd80-a441-4c7b-ba78-e48a8071cae2",
        "shortName": "netflix"
      },
      "references": [
        {
          "url": "https://github.com/Netflix/security-bulletins/blob/master/advisories/nflx-2024-002.md"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Arbitrary File Read Vulnerability in ConsoleMe via Limited Git command RCE",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ea63fd80-a441-4c7b-ba78-e48a8071cae2",
    "assignerShortName": "netflix",
    "cveId": "CVE-2024-5023",
    "datePublished": "2024-05-16T18:05:40.240Z",
    "dateReserved": "2024-05-16T17:55:52.981Z",
    "dateUpdated": "2024-08-01T21:03:09.642Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5035 (GCVE-0-2024-5035)

Vulnerability from cvelistv5 – Published: 2024-05-27 07:22 – Updated: 2024-08-01 21:03
VLAI
Title
TP-Link Archer C5400X - RFTest Unauthenticated Command Injection
Summary
The affected device expose a network service called "rftest" that is vulnerable to unauthenticated command injection on ports TCP/8888, TCP/8889, and TCP/8890. By successfully exploiting this flaw, remote unauthenticated attacker can gain arbitrary command execution on the device with elevated privileges.This issue affects Archer C4500X: through 1_1.1.6.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
TP-Link Archer C4500X Affected: 0 , ≤ 1_1.1.6 (custom)
Create a notification for this product.
tp-link archer_c4500_firmware Affected: 0 , ≤ 1_1.1.6 (custom)
    cpe:2.3:o:tp-link:archer_c4500_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-05-26 23:00
Credits
Quentin Kaiser from ONEKEY Research Labs
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tp-link:archer_c4500_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "archer_c4500_firmware",
            "vendor": "tp-link",
            "versions": [
              {
                "lessThanOrEqual": " 1_1.1.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5035",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-31T14:20:29.272074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:01:50.159Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:03:10.451Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://onekey.com/blog/security-advisory-remote-command-execution-on-tp-link-archer-c5400x/"
          },
          {
            "tags": [
              "vendor-advisory",
              "release-notes",
              "x_transferred"
            ],
            "url": "https://www.tp-link.com/en/support/download/archer-c5400x/#Firmware"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "rftest"
          ],
          "product": "Archer C4500X",
          "vendor": "TP-Link",
          "versions": [
            {
              "lessThanOrEqual": "1_1.1.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "configurations": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "According to TP-Link, the rftest binary is only started in manufacturing mode."
            }
          ],
          "value": "According to TP-Link, the rftest binary is only started in manufacturing mode."
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Quentin Kaiser from ONEKEY Research Labs"
        }
      ],
      "datePublic": "2024-05-26T23:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The affected device expose a network service called \"rftest\" that is vulnerable to unauthenticated command injection on ports TCP/8888, TCP/8889, and TCP/8890.\u0026nbsp;By successfully exploiting this flaw, remote unauthenticated attacker can gain arbitrary command execution on the device with\u0026nbsp;elevated privileges.\u003cp\u003eThis issue affects Archer C4500X: through 1_1.1.6.\u003c/p\u003e"
            }
          ],
          "value": "The affected device expose a network service called \"rftest\" that is vulnerable to unauthenticated command injection on ports TCP/8888, TCP/8889, and TCP/8890.\u00a0By successfully exploiting this flaw, remote unauthenticated attacker can gain arbitrary command execution on the device with\u00a0elevated privileges.This issue affects Archer C4500X: through 1_1.1.6."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-29T04:37:28.917Z",
        "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "shortName": "ONEKEY"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://onekey.com/blog/security-advisory-remote-command-execution-on-tp-link-archer-c5400x/"
        },
        {
          "tags": [
            "vendor-advisory",
            "release-notes"
          ],
          "url": "https://www.tp-link.com/en/support/download/archer-c5400x/#Firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to firmware version 1_1.1.7."
            }
          ],
          "value": "Upgrade to firmware version 1_1.1.7."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "TP-Link Archer C5400X - RFTest Unauthenticated Command Injection",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Limit exposure of ports TCP/8888, TCP/8889, and TCP/9000 works as an interim fix."
            }
          ],
          "value": "Limit exposure of ports TCP/8888, TCP/8889, and TCP/9000 works as an interim fix."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
    "assignerShortName": "ONEKEY",
    "cveId": "CVE-2024-5035",
    "datePublished": "2024-05-27T07:22:59.959Z",
    "dateReserved": "2024-05-16T21:01:26.696Z",
    "dateUpdated": "2024-08-01T21:03:10.451Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50388 (GCVE-0-2024-50388)

Vulnerability from cvelistv5 – Published: 2024-12-06 16:35 – Updated: 2024-12-06 19:59
VLAI
Title
HBS 3 Hybrid Backup Sync
Summary
An OS command injection vulnerability has been reported to affect HBS 3 Hybrid Backup Sync. If exploited, the vulnerability could allow remote attackers to execute commands. We have already fixed the vulnerability in the following version: HBS 3 Hybrid Backup Sync 25.1.1.673 and later
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
Impacted products
Vendor Product Version
QNAP Systems Inc. HBS 3 Hybrid Backup Sync Affected: 25.1.x , < 25.1.1.673 (custom)
Create a notification for this product.
qnap hbs_3 Affected: 25.1.x , < 25.1.1.673 (custom)
    cpe:2.3:a:qnap:hbs_3:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Pwn2Own 2024 - Viettel Cyber Security
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:qnap:hbs_3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "hbs_3",
            "vendor": "qnap",
            "versions": [
              {
                "lessThan": "25.1.1.673",
                "status": "affected",
                "version": "25.1.x",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-50388",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-06T19:30:33.260492Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-06T19:59:55.053Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HBS 3 Hybrid Backup Sync",
          "vendor": "QNAP Systems Inc.",
          "versions": [
            {
              "lessThan": "25.1.1.673",
              "status": "affected",
              "version": "25.1.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pwn2Own 2024 - Viettel Cyber Security"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An OS command injection vulnerability has been reported to affect HBS 3 Hybrid Backup Sync. If exploited, the vulnerability could allow remote attackers to execute commands.\u003cbr\u003e\u003cbr\u003eWe have already fixed the vulnerability in the following version:\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHBS 3 Hybrid Backup Sync 25.1.1.673 and later\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An OS command injection vulnerability has been reported to affect HBS 3 Hybrid Backup Sync. If exploited, the vulnerability could allow remote attackers to execute commands.\n\nWe have already fixed the vulnerability in the following version:\nHBS 3 Hybrid Backup Sync 25.1.1.673 and later"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.5,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77",
              "lang": "en",
              "type": "CWE"
            },
            {
              "cweId": "CWE-78",
              "description": "CWE-78",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-06T16:35:07.434Z",
        "orgId": "2fd009eb-170a-4625-932b-17a53af1051f",
        "shortName": "qnap"
      },
      "references": [
        {
          "url": "https://www.qnap.com/en/security-advisory/qsa-24-41"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "We have already fixed the vulnerability in the following version:\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHBS 3 Hybrid Backup Sync 25.1.1.673 and later\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "We have already fixed the vulnerability in the following version:\nHBS 3 Hybrid Backup Sync 25.1.1.673 and later"
        }
      ],
      "source": {
        "advisory": "QSA-24-41",
        "discovery": "EXTERNAL"
      },
      "title": "HBS 3 Hybrid Backup Sync",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f",
    "assignerShortName": "qnap",
    "cveId": "CVE-2024-50388",
    "datePublished": "2024-12-06T16:35:07.434Z",
    "dateReserved": "2024-10-24T03:41:08.489Z",
    "dateUpdated": "2024-12-06T19:59:55.053Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50591 (GCVE-0-2024-50591)

Vulnerability from cvelistv5 – Published: 2024-11-08 12:01 – Updated: 2025-11-03 22:28
VLAI
Title
Local Privilege Escalation via Command Injection
Summary
An attacker with local access the to medical office computer can escalate his Windows user privileges to "NT AUTHORITY\SYSTEM" by exploiting a command injection vulnerability in the Elefant Update Service. The command injection can be exploited by communicating with the Elefant Update Service which is running as "SYSTEM" via Windows Named Pipes.The Elefant Software Updater (ESU) consists of two components. An ESU service which runs as "NT AUTHORITY\SYSTEM" and an ESU tray client which communicates with the service to update or repair the installation and is running with user permissions. The communication is implemented using named pipes. A crafted message of type "MessageType.SupportServiceInfos" can be sent to the local ESU service to inject commands, which are then executed as "NT AUTHORITY\SYSTEM".
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
HASOMED Elefant Software Updater Affected: <1.4.2.1811 (custom)
Create a notification for this product.
hasomed elefant_software_updater Affected: 0 , < 1.4.2.1811 (custom)
    cpe:2.3:a:hasomed:elefant_software_updater:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Tobias Niemann, SEC Consult Vulnerability Lab Daniel Hirschberger, SEC Consult Vulnerability Lab Florian Stuhlmann, SEC Consult Vulnerability Lab
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hasomed:elefant_software_updater:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "elefant_software_updater",
            "vendor": "hasomed",
            "versions": [
              {
                "lessThan": "1.4.2.1811",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50591",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T15:36:14.988199Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:38:37.109Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T22:28:28.503Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2024/Nov/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Elefant Software Updater",
          "vendor": "HASOMED",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c1.4.2.1811",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Tobias Niemann, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Florian Stuhlmann, SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eAn attacker with local access the to medical office computer can \nescalate his Windows user privileges to \"NT AUTHORITY\\SYSTEM\" by \nexploiting a command injection vulnerability in the Elefant Update \nService. The command injection can be exploited by communicating with \nthe Elefant Update Service which is running as \"SYSTEM\" via Windows \nNamed Pipes.\u003cspan style=\"background-color: var(--wht);\"\u003eThe Elefant Software Updater (ESU) consists of two components. An ESU\n service which runs as \"NT AUTHORITY\\SYSTEM\" and an ESU tray client \nwhich communicates with the service to update or repair the installation\n and is running with user permissions. The communication is implemented \nusing named pipes. A crafted message of type \n\"MessageType.SupportServiceInfos\" can be sent to the local ESU service \nto inject commands, which are then executed as \"NT AUTHORITY\\SYSTEM\".\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "An attacker with local access the to medical office computer can \nescalate his Windows user privileges to \"NT AUTHORITY\\SYSTEM\" by \nexploiting a command injection vulnerability in the Elefant Update \nService. The command injection can be exploited by communicating with \nthe Elefant Update Service which is running as \"SYSTEM\" via Windows \nNamed Pipes.The Elefant Software Updater (ESU) consists of two components. An ESU\n service which runs as \"NT AUTHORITY\\SYSTEM\" and an ESU tray client \nwhich communicates with the service to update or repair the installation\n and is running with user permissions. The communication is implemented \nusing named pipes. A crafted message of type \n\"MessageType.SupportServiceInfos\" can be sent to the local ESU service \nto inject commands, which are then executed as \"NT AUTHORITY\\SYSTEM\"."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-234",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-234 Hijacking a privileged process"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T12:01:18.862Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/hasomed"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://hasomed.de/produkte/elefant/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe vendor fixed the issue in version 1.4.2.1811\u0026nbsp;(or higher) of the Elefant Software Updater which can be downloaded from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://hasomed.de/produkte/elefant/\"\u003ehasomed.de/produkte/elefant/\u003c/a\u003e or via the Elefant Software Updater itself.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "The vendor fixed the issue in version 1.4.2.1811\u00a0(or higher) of the Elefant Software Updater which can be downloaded from  hasomed.de/produkte/elefant/ https://hasomed.de/produkte/elefant/  or via the Elefant Software Updater itself."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Local Privilege Escalation via Command Injection",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eWhile workarounds such as modifying the Elefant windows firewall \nrules and manually adjusting file permissions in the installation folder\n are feasible workarounds for some of the vulnerabilities, it is \nrecommended to install the patches provided by the vendor.\u003c/p\u003e"
            }
          ],
          "value": "While workarounds such as modifying the Elefant windows firewall \nrules and manually adjusting file permissions in the installation folder\n are feasible workarounds for some of the vulnerabilities, it is \nrecommended to install the patches provided by the vendor."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2024-50591",
    "datePublished": "2024-11-08T12:01:18.862Z",
    "dateReserved": "2024-10-25T07:26:12.628Z",
    "dateUpdated": "2025-11-03T22:28:28.503Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-51736 (GCVE-0-2024-51736)

Vulnerability from cvelistv5 – Published: 2024-11-06 20:51 – Updated: 2024-11-21 23:23
VLAI
Title
Command execution hijack on Windows with Process class in symfony/process
Summary
Symphony process is a module for the Symphony PHP framework which executes commands in sub-processes. On Windows, when an executable file named `cmd.exe` is located in the current working directory it will be called by the `Process` class when preparing command arguments, leading to possible hijacking. This issue has been addressed in release versions 5.4.46, 6.4.14, and 7.1.7. Users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
symfony symfony Affected: < 5.4.46
Affected: >= 6.0.0, < 6.4.14
Affected: >= 7.0.0, < 7.1.7
Create a notification for this product.
symfony symfony Affected: 0 , < 5.4.46 (custom)
Affected: 6.0.0 , < 6.4.14 (custom)
Affected: 7.0.0 , < 7.1.7 (custom)
    cpe:2.3:a:symfony:symfony:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:symfony:symfony:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "symfony",
            "vendor": "symfony",
            "versions": [
              {
                "lessThan": "5.4.46",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "6.4.14",
                "status": "affected",
                "version": "6.0.0",
                "versionType": "custom"
              },
              {
                "lessThan": "7.1.7",
                "status": "affected",
                "version": "7.0.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-51736",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T23:20:34.134307Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T23:23:26.713Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "symfony",
          "vendor": "symfony",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 5.4.46"
            },
            {
              "status": "affected",
              "version": "\u003e= 6.0.0, \u003c 6.4.14"
            },
            {
              "status": "affected",
              "version": "\u003e= 7.0.0, \u003c 7.1.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Symphony process is a module for the Symphony PHP framework which executes commands in sub-processes. On Windows, when an executable file named `cmd.exe` is located in the current working directory it will be called by the `Process` class when preparing command arguments, leading to possible hijacking. This issue has been addressed in release versions 5.4.46, 6.4.14, and 7.1.7. Users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 0,
            "baseSeverity": "NONE",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-06T20:51:38.536Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/symfony/symfony/security/advisories/GHSA-qq5c-677p-737q",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/symfony/symfony/security/advisories/GHSA-qq5c-677p-737q"
        },
        {
          "name": "https://github.com/symfony/symfony/security/advisories/GHSA-qq5c-677p-737q",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/symfony/symfony/security/advisories/GHSA-qq5c-677p-737q"
        }
      ],
      "source": {
        "advisory": "GHSA-qq5c-677p-737q",
        "discovery": "UNKNOWN"
      },
      "title": "Command execution hijack on Windows with Process class in symfony/process"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2024-51736",
    "datePublished": "2024-11-06T20:51:38.536Z",
    "dateReserved": "2024-10-31T14:12:45.788Z",
    "dateUpdated": "2024-11-21T23:23:26.713Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5194 (GCVE-0-2024-5194)

Vulnerability from cvelistv5 – Published: 2024-05-22 11:00 – Updated: 2024-08-01 21:03
VLAI
Title
Arris VAP2500 assoc_table.php command injection
Summary
A vulnerability was found in Arris VAP2500 08.50. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /assoc_table.php. The manipulation of the argument id leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-265831.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.265831 vdb-entrytechnical-description
https://vuldb.com/?ctiid.265831 signaturepermissions-required
https://vuldb.com/?submit.335252 third-party-advisory
https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/… exploit
Impacted products
Vendor Product Version
Arris VAP2500 Affected: 08.50
Create a notification for this product.
arris vap2500_firmware Affected: 08.50
    cpe:2.3:o:arris:vap2500_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
H0e4a0r1t (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:arris:vap2500_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap2500_firmware",
            "vendor": "arris",
            "versions": [
              {
                "status": "affected",
                "version": "08.50"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5194",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-22T18:09:28.197302Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:02:13.842Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:03:11.059Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-265831 | Arris VAP2500 assoc_table.php command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.265831"
          },
          {
            "name": "VDB-265831 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.265831"
          },
          {
            "name": "Submit #335252 | Arris Group Arris VAP2500 AT.08.50 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.335252"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/a%2B%26%5BE4%3Flp5%3Fk9_%3D%5D/ARRIS_VAP2500-RCE-assoc_table.php.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VAP2500",
          "vendor": "Arris",
          "versions": [
            {
              "status": "affected",
              "version": "08.50"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "H0e4a0r1t (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Arris VAP2500 08.50. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /assoc_table.php. The manipulation of the argument id leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-265831."
        },
        {
          "lang": "de",
          "value": "In Arris VAP2500 08.50 wurde eine kritische Schwachstelle ausgemacht. Das betrifft eine unbekannte Funktionalit\u00e4t der Datei /assoc_table.php. Mittels dem Manipulieren des Arguments id mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-22T11:00:05.367Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-265831 | Arris VAP2500 assoc_table.php command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.265831"
        },
        {
          "name": "VDB-265831 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.265831"
        },
        {
          "name": "Submit #335252 | Arris Group Arris VAP2500 AT.08.50 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.335252"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/a%2B%26%5BE4%3Flp5%3Fk9_%3D%5D/ARRIS_VAP2500-RCE-assoc_table.php.pdf"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-05-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-05-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-05-22T07:26:05.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Arris VAP2500 assoc_table.php command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-5194",
    "datePublished": "2024-05-22T11:00:05.367Z",
    "dateReserved": "2024-05-22T05:20:54.141Z",
    "dateUpdated": "2024-08-01T21:03:11.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5195 (GCVE-0-2024-5195)

Vulnerability from cvelistv5 – Published: 2024-05-22 11:00 – Updated: 2024-08-01 21:03
VLAI
Title
Arris VAP2500 diag_s.php command injection
Summary
A vulnerability was found in Arris VAP2500 08.50. It has been rated as critical. Affected by this issue is some unknown functionality of the file /diag_s.php. The manipulation of the argument customer_info leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265832.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.265832 vdb-entrytechnical-description
https://vuldb.com/?ctiid.265832 signaturepermissions-required
https://vuldb.com/?submit.335253 third-party-advisory
https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/… exploit
Impacted products
Vendor Product Version
Arris VAP2500 Affected: 08.50
Create a notification for this product.
Credits
H0e4a0r1t (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5195",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-23T19:41:02.400663Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:02:11.176Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:03:11.096Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-265832 | Arris VAP2500 diag_s.php command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.265832"
          },
          {
            "name": "VDB-265832 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.265832"
          },
          {
            "name": "Submit #335253 | Arris Group Arris VAP2500 AT.08.50 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.335253"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/a%2B%26%5BE4%3Flp5%3Fk9_%3D%5D/ARRIS_VAP2500-RCE-diag_s.php.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VAP2500",
          "vendor": "Arris",
          "versions": [
            {
              "status": "affected",
              "version": "08.50"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "H0e4a0r1t (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Arris VAP2500 08.50. It has been rated as critical. Affected by this issue is some unknown functionality of the file /diag_s.php. The manipulation of the argument customer_info leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265832."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Arris VAP2500 08.50 ausgemacht. Dies betrifft einen unbekannten Teil der Datei /diag_s.php. Mittels Manipulieren des Arguments customer_info mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-22T11:00:06.975Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-265832 | Arris VAP2500 diag_s.php command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.265832"
        },
        {
          "name": "VDB-265832 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.265832"
        },
        {
          "name": "Submit #335253 | Arris Group Arris VAP2500 AT.08.50 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.335253"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/a%2B%26%5BE4%3Flp5%3Fk9_%3D%5D/ARRIS_VAP2500-RCE-diag_s.php.pdf"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-05-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-05-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-05-22T07:26:06.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Arris VAP2500 diag_s.php command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-5195",
    "datePublished": "2024-05-22T11:00:06.975Z",
    "dateReserved": "2024-05-22T05:20:56.227Z",
    "dateUpdated": "2024-08-01T21:03:11.096Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
Mitigation

Phase: Implementation

Description:

  • If possible, ensure that all external commands called from the program are statically created.
Mitigation ID: MIT-5

Phase: Implementation

Strategy: Input Validation

Description:

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
Mitigation

Phase: Operation

Description:

  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
Mitigation

Phase: System Configuration

Description:

  • Assign permissions that prevent the user from accessing/opening privileged files.
CAPEC-136: LDAP Injection

An attacker manipulates or crafts an LDAP query for the purpose of undermining the security of the target. Some applications use user input to create LDAP queries that are processed by an LDAP server. For example, a user might provide their username during authentication and the username might be inserted in an LDAP query during the authentication process. An attacker could use this input to inject additional commands into an LDAP query that could disclose sensitive information. For example, entering a * in the aforementioned query might return information about all users on the system. This attack is very similar to an SQL injection attack in that it manipulates a query to gather additional information or coerce a particular return value.

CAPEC-15: Command Delimiters

An attack of this type exploits a programs' vulnerabilities that allows an attacker's commands to be concatenated onto a legitimate command with the intent of targeting other resources such as the file system or database. The system that uses a filter or denylist input validation, as opposed to allowlist validation is vulnerable to an attacker who predicts delimiters (or combinations of delimiters) not present in the filter or denylist. As with other injection attacks, the attacker uses the command delimiter payload as an entry point to tunnel through the application and activate additional attacks through SQL queries, shell commands, network scanning, and so on.

CAPEC-183: IMAP/SMTP Command Injection

An adversary exploits weaknesses in input validation on web-mail servers to execute commands on the IMAP/SMTP server. Web-mail servers often sit between the Internet and the IMAP or SMTP mail server. User requests are received by the web-mail servers which then query the back-end mail server for the requested information and return this response to the user. In an IMAP/SMTP command injection attack, mail-server commands are embedded in parts of the request sent to the web-mail server. If the web-mail server fails to adequately sanitize these requests, these commands are then sent to the back-end mail server when it is queried by the web-mail server, where the commands are then executed. This attack can be especially dangerous since administrators may assume that the back-end server is protected against direct Internet access and therefore may not secure it adequately against the execution of malicious commands.

CAPEC-248: Command Injection

An adversary looking to execute a command of their choosing, injects new items into an existing command thus modifying interpretation away from what was intended. Commands in this context are often standalone strings that are interpreted by a downstream component and cause specific responses. This type of attack is possible when untrusted values are used to build these command strings. Weaknesses in input validation or command construction can enable the attack and lead to successful exploitation.

CAPEC-40: Manipulating Writeable Terminal Devices

This attack exploits terminal devices that allow themselves to be written to by other users. The attacker sends command strings to the target terminal device hoping that the target user will hit enter and thereby execute the malicious command with their privileges. The attacker can send the results (such as copying /etc/passwd) to a known directory and collect once the attack has succeeded.

CAPEC-43: Exploiting Multiple Input Interpretation Layers

An attacker supplies the target software with input data that contains sequences of special characters designed to bypass input validation logic. This exploit relies on the target making multiples passes over the input data and processing a "layer" of special characters with each pass. In this manner, the attacker can disguise input that would otherwise be rejected as invalid by concealing it with layers of special/escape characters that are stripped off by subsequent processing steps. The goal is to first discover cases where the input validation layer executes before one or more parsing layers. That is, user input may go through the following logic in an application: <parser1> --> <input validator> --> <parser2>. In such cases, the attacker will need to provide input that will pass through the input validator, but after passing through parser2, will be converted into something that the input validator was supposed to stop.

CAPEC-75: Manipulating Writeable Configuration Files

Generally these are manually edited files that are not in the preview of the system administrators, any ability on the attackers' behalf to modify these files, for example in a CVS repository, gives unauthorized access directly to the application, the same as authorized users.

CAPEC-76: Manipulating Web Input to File System Calls

An attacker manipulates inputs to the target software which the target software passes to file system calls in the OS. The goal is to gain access to, and perhaps modify, areas of the file system that the target software did not intend to be accessible.

Back to CWE stats page