Search criteria
42 vulnerabilities
CVE-2021-32007 (GCVE-0-2021-32007)
Vulnerability from cvelistv5 – Published: 2024-12-13 11:05 – Updated: 2024-12-23 19:14
VLAI?
Summary
This issue affects:
Secomea GateManager
Version 9.5 and all prior versions.
Protection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , ≤ 9.5
(custom)
|
Credits
Regel Partners B.V.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-32007",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-23T19:14:40.946759Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-23T19:14:49.546Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Regel Partners B.V."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue affects:\u003cbr\u003eSecomea GateManager\u003cbr\u003eVersion 9.5 and all prior versions.\u003cbr\u003eProtection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers."
}
],
"value": "This issue affects:\nSecomea GateManager\nVersion 9.5 and all prior versions.\nProtection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers."
}
],
"impacts": [
{
"capecId": "CAPEC-116",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-116 Excavation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-13T11:05:58.370Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Missing security header: Referrer-Policy URL",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32007",
"datePublished": "2024-12-13T11:05:58.370Z",
"dateReserved": "2021-05-03T16:28:23.358Z",
"dateUpdated": "2024-12-23T19:14:49.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1969 (GCVE-0-2024-1969)
Vulnerability from cvelistv5 – Published: 2024-04-29 13:29 – Updated: 2024-08-01 18:56
VLAI?
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.
Severity ?
8.2 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
9.7 , < 11.2.624095033
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:secomea:gatemanager:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gatemanager",
"vendor": "secomea",
"versions": [
{
"status": "affected",
"version": "9.7"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1969",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T15:12:46.757035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T18:00:05.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:56:22.773Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"webserver"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.2.624095033",
"status": "affected",
"version": "9.7",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.\u003cp\u003eThis issue affects GateManager: from 9.7 before 11.2.624095033.\u003c/p\u003e"
}
],
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-29T13:29:01.094Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6718"
],
"discovery": "INTERNAL"
},
"title": "Heap buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2024-1969",
"datePublished": "2024-04-29T13:29:01.094Z",
"dateReserved": "2024-02-28T14:49:31.001Z",
"dateUpdated": "2024-08-01T18:56:22.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1579 (GCVE-0-2024-1579)
Vulnerability from cvelistv5 – Published: 2024-04-29 13:27 – Updated: 2024-08-01 18:40
VLAI?
Summary
Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.This issue affects GateManager: before 11.2.624071020.
Severity ?
8.1 (High)
CWE
- CWE-335 - Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , < 11.2.624071020
(custom)
|
Credits
Researchers at Paderborn University and Ruhr University Bochum
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:secomea:gatemanager:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gatemanager",
"vendor": "secomea",
"versions": [
{
"lessThan": "11.2.62.4971020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1579",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T14:34:13.948903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:59:30.225Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:21.431Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Webserver"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.2.624071020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Researchers at Paderborn University and Ruhr University Bochum"
}
],
"datePublic": "2024-04-29T13:21:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.\u003cp\u003eThis issue affects GateManager: before 11.2.624071020.\u003c/p\u003e"
}
],
"value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.This issue affects GateManager: before 11.2.624071020.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-593",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-593 Session Hijacking"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-335",
"description": "CWE-335 Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-29T13:27:55.045Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6690"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient seeding of random number generator",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2024-1579",
"datePublished": "2024-04-29T13:27:55.045Z",
"dateReserved": "2024-02-16T12:11:01.147Z",
"dateUpdated": "2024-08-01T18:40:21.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3675 (GCVE-0-2023-3675)
Vulnerability from cvelistv5 – Published: 2024-04-18 10:41 – Updated: 2024-08-21 14:08
VLAI?
Summary
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.This issue affects GateManager: from 11.0.623074018 before 11.0.623373051.
Severity ?
6.5 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
11.0.623074018 , < 11.0.623373051
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3675",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T14:08:31.273757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T14:08:41.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web GUI"
],
"platforms": [
"Linux"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.0.623373051",
"status": "affected",
"version": "11.0.623074018",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-04-18T10:40:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.\u003cp\u003eThis issue affects GateManager: from 11.0.623074018 before 11.0.623373051.\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.This issue affects GateManager: from 11.0.623074018 before 11.0.623373051.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-545",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-545 Pull Data from System Resources"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-18T10:41:32.348Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-6533"
],
"discovery": "INTERNAL"
},
"title": "Insufficient input validation when downloading certain file types.",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2023-3675",
"datePublished": "2024-04-18T10:41:25.088Z",
"dateReserved": "2023-07-14T12:57:35.931Z",
"dateUpdated": "2024-08-21T14:08:41.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2912 (GCVE-0-2023-2912)
Vulnerability from cvelistv5 – Published: 2023-07-17 12:31 – Updated: 2024-10-22 13:40
VLAI?
Summary
Use After Free vulnerability in Secomea SiteManager Embedded allows Obstruction.
Severity ?
5.9 (Medium)
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager Embedded |
Affected:
0 , < 11.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:41:03.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2912",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T13:32:57.213994Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T13:40:14.960Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SiteManager Embedded",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use After Free vulnerability in Secomea SiteManager Embedded allows Obstruction."
}
],
"value": "Use After Free vulnerability in Secomea SiteManager Embedded allows Obstruction."
}
],
"impacts": [
{
"capecId": "CAPEC-607",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-607 Obstruction"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-17T12:31:05.854Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6401"
],
"discovery": "INTERNAL"
},
"title": "SiteManager Embedded service disruption",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2023-2912",
"datePublished": "2023-07-17T12:31:05.854Z",
"dateReserved": "2023-05-26T12:17:30.753Z",
"dateUpdated": "2024-10-22T13:40:14.960Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38125 (GCVE-0-2022-38125)
Vulnerability from cvelistv5 – Published: 2023-04-19 11:58 – Updated: 2025-02-05 15:00
VLAI?
Summary
Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client.
Severity ?
CWE
- CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
5.0 , ≤ 10.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:45:52.834Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-38125",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T14:59:41.569876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:00:42.143Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"FTP Agent"
],
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "10.0",
"status": "affected",
"version": "5.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-19T11:58:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
}
],
"value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
}
],
"impacts": [
{
"capecId": "CAPEC-22",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-22 Exploiting Trust in Client"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-19T11:58:14.508Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "FTP Agent forwards traffic on inactive ports to LinkManager",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-38125",
"datePublished": "2023-04-19T11:58:14.508Z",
"dateReserved": "2022-08-10T09:46:05.634Z",
"dateUpdated": "2025-02-05T15:00:42.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0317 (GCVE-0-2023-0317)
Vulnerability from cvelistv5 – Published: 2023-04-19 11:57 – Updated: 2025-02-05 15:03
VLAI?
Summary
Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information.
Severity ?
4.9 (Medium)
CWE
- CWE-420 - Unprotected Alternate Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
10.0 , < 10.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:10:55.186Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-0317",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T15:02:04.508680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:03:03.498Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.1",
"status": "affected",
"version": "10.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-19T11:57:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information."
}
],
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information."
}
],
"impacts": [
{
"capecId": "CAPEC-383",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-383 Harvesting Information via API Event Monitoring"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-19T11:57:46.409Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "GateManager debug interface is included in non-debug builds",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2023-0317",
"datePublished": "2023-04-19T11:57:46.409Z",
"dateReserved": "2023-01-16T09:36:00.479Z",
"dateUpdated": "2025-02-05T15:03:03.498Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4308 (GCVE-0-2022-4308)
Vulnerability from cvelistv5 – Published: 2023-04-19 11:56 – Updated: 2025-02-05 15:05
VLAI?
Summary
Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked.
Severity ?
6.1 (Medium)
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
5.0 , < 10.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:34:50.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-4308",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T15:04:01.779043Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:05:16.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"USB wizard"
],
"platforms": [
"Linux"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.1",
"status": "affected",
"version": "5.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-19T11:51:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked."
}
],
"value": "Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-19T11:56:55.106Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Clear-text passwords in configuration files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-4308",
"datePublished": "2023-04-19T11:56:32.348Z",
"dateReserved": "2022-12-06T13:33:10.501Z",
"dateUpdated": "2025-02-05T15:05:16.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38124 (GCVE-0-2022-38124)
Vulnerability from cvelistv5 – Published: 2022-12-13 13:06 – Updated: 2025-04-18 15:28
VLAI?
Summary
Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner.
Severity ?
5.7 (Medium)
CWE
- CWE-267 - Privilege Defined With Unsafe Actions
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
0 , ≤ 10.0.622425017
("custom")
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:45:52.627Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:28:06.181233Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T15:28:20.215Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "10.0.622425017",
"status": "affected",
"version": "0",
"versionType": "\"custom\""
}
]
}
],
"datePublic": "2022-12-12T23:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
}
],
"value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
}
],
"impacts": [
{
"capecId": "CAPEC-121",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-121 Exploit Test APIs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-267",
"description": "CWE-267 Privilege Defined With Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T13:06:17.021Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6294"
],
"discovery": "EXTERNAL"
},
"title": "Unwanted debug tool",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-38124",
"datePublished": "2022-12-13T13:06:17.021Z",
"dateReserved": "2022-08-10T09:46:05.634Z",
"dateUpdated": "2025-04-18T15:28:20.215Z",
"requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2752 (GCVE-0-2022-2752)
Vulnerability from cvelistv5 – Published: 2022-12-09 13:30 – Updated: 2025-04-22 19:44
VLAI?
Summary
A vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.
This issue affects:
Secomea GateManager versions from 9.4 through 9.7.
Severity ?
5.5 (Medium)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
9.4 , < 10.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:46:04.419Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2752",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T19:44:26.372042Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T19:44:33.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.0",
"status": "affected",
"version": "9.4",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-09T11:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.\u003c/div\u003e\u003cdiv\u003eThis issue affects:\u003c/div\u003e\u003cdiv\u003eSecomea GateManager versions from 9.4 through 9.7.\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.\n\nThis issue affects:\n\nSecomea GateManager versions from 9.4 through 9.7.\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-09T13:30:26.346Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5896"
],
"discovery": "EXTERNAL"
},
"title": "Potential vulnerabilities in GM login process",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-2752",
"datePublished": "2022-12-09T13:30:26.346Z",
"dateReserved": "2022-08-10T09:43:33.129Z",
"dateUpdated": "2025-04-22T19:44:33.832Z",
"requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38123 (GCVE-0-2022-38123)
Vulnerability from cvelistv5 – Published: 2022-12-06 15:58 – Updated: 2025-04-23 16:12
VLAI?
Summary
Improper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.
This issue affects:
Secomea GateManager
versions prior to 10.0.
Severity ?
8.7 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , < 10.0
("custom")
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:45:52.623Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T16:12:26.690794Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T16:12:37.744Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.0",
"status": "affected",
"version": "0",
"versionType": "\"custom\""
}
]
}
],
"datePublic": "2022-12-05T23:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eImproper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.\u003c/div\u003e\u003cdiv\u003eThis issue affects:\u003c/div\u003e\u003cdiv\u003eSecomea GateManager\u003c/div\u003e\u003cdiv\u003eversions prior to 10.0.\u003c/div\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Improper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.\n\nThis issue affects:\n\nSecomea GateManager\n\nversions prior to 10.0.\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-242",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-242 Code Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-06T15:59:52.408Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5851"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient validation of plugin files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-38123",
"datePublished": "2022-12-06T15:58:01.365Z",
"dateReserved": "2022-08-10T09:46:05.632Z",
"dateUpdated": "2025-04-23T16:12:37.744Z",
"requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25786 (GCVE-0-2022-25786)
Vulnerability from cvelistv5 – Published: 2022-05-04 17:17 – Updated: 2024-08-03 04:49
VLAI?
Summary
Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7.
Severity ?
4.9 (Medium)
CWE
- CWE-420 - Unprotected Alternate Channel
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.267Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T17:17:34",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5457"
],
"discovery": "INTERNAL"
},
"title": "GateManager debug interface is included in production builds",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25786",
"STATE": "PUBLIC",
"TITLE": "GateManager debug interface is included in production builds"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-420 Unprotected Alternate Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5457"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25786",
"datePublished": "2022-05-04T17:17:34",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25787 (GCVE-0-2022-25787)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:58 – Updated: 2024-08-03 04:49
VLAI?
Summary
Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7.
Severity ?
7.5 (High)
CWE
- CWE-598 - Information Exposure Through Query Strings in GET Request
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Information Exposure Through Query Strings in GET Request",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:58:45",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5523"
],
"discovery": "INTERNAL"
},
"title": "GTA URLs issued by LMM WEB API may leak information",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25787",
"STATE": "PUBLIC",
"TITLE": "GTA URLs issued by LMM WEB API may leak information"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-598 Information Exposure Through Query Strings in GET Request"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5523"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25787",
"datePublished": "2022-05-04T13:58:45",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25785 (GCVE-0-2022-25785)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:57 – Updated: 2024-08-03 04:49
VLAI?
Summary
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.
Severity ?
6.6 (Medium)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.219Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:57:06",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5455"
],
"discovery": "INTERNAL"
},
"title": "Buffer overrun",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25785",
"STATE": "PUBLIC",
"TITLE": "Buffer overrun"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5455"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25785",
"datePublished": "2022-05-04T13:57:06",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25784 (GCVE-0-2022-25784)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:56 – Updated: 2024-08-03 04:49
VLAI?
Summary
Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7.
Severity ?
9.1 (Critical)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.564Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:56:20",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5371"
],
"discovery": "INTERNAL"
},
"title": "User controllable HTML element attribute (potential XSS)",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25784",
"STATE": "PUBLIC",
"TITLE": "User controllable HTML element attribute (potential XSS)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5371"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25784",
"datePublished": "2022-05-04T13:56:20",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.564Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25783 (GCVE-0-2022-25783)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:55 – Updated: 2024-08-03 04:49
VLAI?
Summary
Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
4.3 (Medium)
CWE
- CWE-778 - Insufficient Logging
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-778",
"description": "CWE-778 Insufficient Logging",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:55:13",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5355"
],
"discovery": "INTERNAL"
},
"title": "Hacking attempts from logged-in users are not properly logged by GM",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25783",
"STATE": "PUBLIC",
"TITLE": "Hacking attempts from logged-in users are not properly logged by GM"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-778 Insufficient Logging"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5355"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25783",
"datePublished": "2022-05-04T13:55:13",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25782 (GCVE-0-2022-25782)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:54 – Updated: 2024-08-03 04:49
VLAI?
Summary
Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
5.4 (Medium)
CWE
- CWE-274 - Improper Handling of Insufficient Privileges
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.231Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-274",
"description": "CWE-274 Improper Handling of Insufficient Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:54:16",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5335"
],
"discovery": "INTERNAL"
},
"title": "Insufficient privilege checks on object access and updates.",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25782",
"STATE": "PUBLIC",
"TITLE": "Insufficient privilege checks on object access and updates."
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-274 Improper Handling of Insufficient Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5335"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25782",
"datePublished": "2022-05-04T13:54:16",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25781 (GCVE-0-2022-25781)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:53 – Updated: 2024-08-03 04:49
VLAI?
Summary
Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session.
Severity ?
4.2 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:53:17",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5314"
],
"discovery": "INTERNAL"
},
"title": "Reflected XSS issues in GateManager",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25781",
"STATE": "PUBLIC",
"TITLE": "Reflected XSS issues in GateManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5314"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25781",
"datePublished": "2022-05-04T13:53:17",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.192Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25780 (GCVE-0-2022-25780)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:52 – Updated: 2024-08-03 04:49
VLAI?
Summary
Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope.
Severity ?
4.3 (Medium)
CWE
- CWE-200 - Information Exposure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.496Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:52:15",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5310"
],
"discovery": "INTERNAL"
},
"title": "Information leak via device availability query function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25780",
"STATE": "PUBLIC",
"TITLE": "Information leak via device availability query function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200 Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5310"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25780",
"datePublished": "2022-05-04T13:52:15",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.496Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25779 (GCVE-0-2022-25779)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:51 – Updated: 2024-08-03 04:49
VLAI?
Summary
Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
4.3 (Medium)
CWE
- CWE-779 - Logging of Excessive Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.260Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-779",
"description": "CWE-779 Logging of Excessive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:51:08",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5309"
],
"discovery": "INTERNAL"
},
"title": "Insufficient scope checks allows adding unrelated audit log entries",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25779",
"STATE": "PUBLIC",
"TITLE": "Insufficient scope checks allows adding unrelated audit log entries"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-779 Logging of Excessive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5309"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25779",
"datePublished": "2022-05-04T13:51:08",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.260Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25778 (GCVE-0-2022-25778)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:49 – Updated: 2024-08-03 04:49
VLAI?
Summary
Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session.
Severity ?
4.2 (Medium)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.681Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:49:55",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5308"
],
"discovery": "INTERNAL"
},
"title": "Unload handlers may unintentionally defeat CSRF guards",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25778",
"STATE": "PUBLIC",
"TITLE": "Unload handlers may unintentionally defeat CSRF guards"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352 Cross-Site Request Forgery (CSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5308"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25778",
"datePublished": "2022-05-04T13:49:55",
"dateReserved": "2022-02-22T00:00:00",
"dateUpdated": "2024-08-03T04:49:43.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32010 (GCVE-0-2021-32010)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17
VLAI?
Summary
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
Severity ?
5.6 (Medium)
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.7
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
},
{
"product": "LinkManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326 Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:45:03",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
},
"title": "Clients may connect to a GateManager with TLS 1.0",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32010",
"STATE": "PUBLIC",
"TITLE": "Clients may connect to a GateManager with TLS 1.0"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.7"
}
]
}
},
{
"product_name": "LinkManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
},
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326 Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32010",
"datePublished": "2022-05-04T13:45:03",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:28.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32009 (GCVE-0-2021-32009)
Vulnerability from cvelistv5 – Published: 2022-03-11 17:53 – Updated: 2024-08-03 23:17
VLAI?
Summary
Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions.
Severity ?
5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.154Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-11T17:53:58",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5196"
],
"discovery": "INTERNAL"
},
"title": "Missing XSS guards on firmware page",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32009",
"STATE": "PUBLIC",
"TITLE": "Missing XSS guards on firmware page"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-5196"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32009",
"datePublished": "2022-03-11T17:53:58",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:28.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32005 (GCVE-0-2021-32005)
Vulnerability from cvelistv5 – Published: 2022-03-07 15:21 – Updated: 2024-08-03 23:17
VLAI?
Summary
Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions.
Severity ?
6.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
Credits
Schlumberger
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:27.941Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Schlumberger"
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-07T15:21:27",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
}
],
"source": {
"defect": [
"RD-5017"
],
"discovery": "EXTERNAL"
},
"title": "SiteManager Log View XSS Issue",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32005",
"STATE": "PUBLIC",
"TITLE": "SiteManager Log View XSS Issue"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Schlumberger"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#5017",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
}
]
},
"source": {
"defect": [
"RD-5017"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32005",
"datePublished": "2022-03-07T15:21:27",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:27.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32006 (GCVE-0-2021-32006)
Vulnerability from cvelistv5 – Published: 2022-03-07 15:08 – Updated: 2024-08-03 23:17
VLAI?
Summary
This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files.
Severity ?
5 (Medium)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
Credits
Schlumberger
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.226Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Schlumberger"
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-275",
"description": "CWE-275 Permission Issues",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-274",
"description": "CWE-274 Improper Handling of Insufficient Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-07T15:08:16",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5018"
],
"discovery": "EXTERNAL"
},
"title": "GateManager information leak for LinkManager Users",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32006",
"STATE": "PUBLIC",
"TITLE": "GateManager information leak for LinkManager Users"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Schlumberger"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-275 Permission Issues"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-274 Improper Handling of Insufficient Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5018"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32006",
"datePublished": "2022-03-07T15:08:16",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:28.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32008 (GCVE-0-2021-32008)
Vulnerability from cvelistv5 – Published: 2022-03-04 21:20 – Updated: 2024-08-03 23:17
VLAI?
Summary
This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories.
Severity ?
9.9 (Critical)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:27.898Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-04T21:20:10",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5197"
],
"discovery": "INTERNAL"
},
"title": "Logged-in Administrator may get unrestricted file system access",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32008",
"STATE": "PUBLIC",
"TITLE": "Logged-in Administrator may get unrestricted file system access"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-552 Files or Directories Accessible to External Parties"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-5197"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32008",
"datePublished": "2022-03-04T21:20:10",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:27.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32004 (GCVE-0-2021-32004)
Vulnerability from cvelistv5 – Published: 2021-11-22 20:32 – Updated: 2024-08-03 23:17
VLAI?
Summary
This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning.
Severity ?
CWE
- CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.6
(custom)
|
Credits
Acunetix
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.501Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.6",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Acunetix"
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-22T20:32:45",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
],
"source": {
"defect": [
"RD-4578"
],
"discovery": "EXTERNAL"
},
"title": "GateManager does not enforce strict hostname matching for WEB server",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32004",
"STATE": "PUBLIC",
"TITLE": "GateManager does not enforce strict hostname matching for WEB server"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.6"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Acunetix"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#4578",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
]
},
"source": {
"defect": [
"RD-4578"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32004",
"datePublished": "2021-11-22T20:32:45",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:28.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32003 (GCVE-0-2021-32003)
Vulnerability from cvelistv5 – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Summary
Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
Severity ?
CWE
- CWE-523 - Unprotected Transport of Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:27.897Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"Hardware"
],
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.5",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-523",
"description": "CWE-523 Unprotected Transport of Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-05T20:33:30",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-3777"
],
"discovery": "INTERNAL"
},
"title": "Configuration service port remains open 10 minutes after reboot even when already provisioned",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32003",
"STATE": "PUBLIC",
"TITLE": "Configuration service port remains open 10 minutes after reboot even when already provisioned"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"platform": "Hardware",
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.5"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-523 Unprotected Transport of Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-3777"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32003",
"datePublished": "2021-08-05T20:33:30",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:27.897Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32002 (GCVE-0-2021-32002)
Vulnerability from cvelistv5 – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
Severity ?
4.3 (Medium)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:27.964Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"Hardware"
],
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.5",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-05T20:33:27",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-3776"
],
"discovery": "INTERNAL"
},
"title": "SiteManager troubleshooter allows access without authentication from local network ",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32002",
"STATE": "PUBLIC",
"TITLE": "SiteManager troubleshooter allows access without authentication from local network "
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"platform": "Hardware",
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.5"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-200 Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-3776"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32002",
"datePublished": "2021-08-05T20:33:27",
"dateReserved": "2021-05-03T00:00:00",
"dateUpdated": "2024-08-03T23:17:27.964Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29030 (GCVE-0-2020-29030)
Vulnerability from cvelistv5 – Published: 2021-03-05 19:15 – Updated: 2024-09-17 00:31
VLAI?
Summary
Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4.
Severity ?
8.1 (High)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.4
(custom)
|
Credits
Schneider Electric
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Schneider Electric"
}
],
"datePublic": "2021-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-05T19:15:27",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-2417"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient CSRF guards",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29030",
"STATE": "PUBLIC",
"TITLE": "Insufficient CSRF guards"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.4"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Schneider Electric"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352 Cross-Site Request Forgery (CSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-2417"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29030",
"datePublished": "2021-03-05T19:15:27.247684Z",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-09-17T00:31:38.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}