Vulnerabilites related to Dell - Isilon OneFS
cve-2020-5355
Vulnerability from cvelistv5
Published
2022-10-21 18:05
Modified
2024-09-16 16:52
Severity ?
EPSS score ?
Summary
The Dell Isilon OneFS versions 8.2.2 and earlier SSHD process improperly allows Transmission Control Protocol (TCP) and stream forwarding. This provides the remotesupport user and users with restricted shells more access than is intended.
References
▼ | URL | Tags |
---|---|---|
https://support.emc.com/kb/543561 |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://support.emc.com/kb/543561" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2021-11-23T00:00:00", "descriptions": [ { "lang": "en", "value": "The Dell Isilon OneFS versions 8.2.2 and earlier SSHD process improperly allows Transmission Control Protocol (TCP) and stream forwarding. This provides the remotesupport user and users with restricted shells more access than is intended." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-21T00:00:00", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "url": "https://support.emc.com/kb/543561" } ] } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5355", "datePublished": "2022-10-21T18:05:24.132862Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T16:52:53.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5369
Vulnerability from cvelistv5
Published
2020-09-02 20:55
Modified
2024-09-16 19:46
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 contain a privilege escalation vulnerability. An authenticated malicious user may exploit this vulnerability by using SyncIQ to gain unauthorized access to system management files.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.1.2, 8.2.2, 9.0.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.806Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/546160/DSA-2020-142-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-OneFS-Security-Update-for-SyncIQ-Privi" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.1.2, 8.2.2, 9.0.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-08-28T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 contain a privilege escalation vulnerability. An authenticated malicious user may exploit this vulnerability by using SyncIQ to gain unauthorized access to system management files." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-09-02T20:55:17", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/546160/DSA-2020-142-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-OneFS-Security-Update-for-SyncIQ-Privi" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-08-28", "ID": "CVE-2020-5369", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1.2, 8.2.2, 9.0.0" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 contain a privilege escalation vulnerability. An authenticated malicious user may exploit this vulnerability by using SyncIQ to gain unauthorized access to system management files." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-732: Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/546160/DSA-2020-142-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-OneFS-Security-Update-for-SyncIQ-Privi", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/546160/DSA-2020-142-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-OneFS-Security-Update-for-SyncIQ-Privi" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5369", "datePublished": "2020-09-02T20:55:17.768175Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T19:46:53.889Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5347
Vulnerability from cvelistv5
Published
2020-04-03 23:20
Modified
2024-09-16 18:28
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions 8.2.2 and earlier contain a denial of service vulnerability. SmartConnect had an error condition that may be triggered to loop, using CPU and potentially preventing other SmartConnect DNS responses.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.308Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/542190/DSA-2020-054-Dell-EMC-Isilon-OneFS-Security-Update-for-DNS-Protocol-Vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-03-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier contain a denial of service vulnerability. SmartConnect had an error condition that may be triggered to loop, using CPU and potentially preventing other SmartConnect DNS responses." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-03T23:20:13", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/542190/DSA-2020-054-Dell-EMC-Isilon-OneFS-Security-Update-for-DNS-Protocol-Vulnerabilities" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-03-20", "ID": "CVE-2020-5347", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier contain a denial of service vulnerability. SmartConnect had an error condition that may be triggered to loop, using CPU and potentially preventing other SmartConnect DNS responses." } ] }, "impact": { "cvss": { "baseScore": 5.3, "baseSeverity": "Medium", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/542190/DSA-2020-054-Dell-EMC-Isilon-OneFS-Security-Update-for-DNS-Protocol-Vulnerabilities", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/542190/DSA-2020-054-Dell-EMC-Isilon-OneFS-Security-Update-for-DNS-Protocol-Vulnerabilities" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5347", "datePublished": "2020-04-03T23:20:14.052775Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T18:28:55.455Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5328
Vulnerability from cvelistv5
Published
2020-03-06 20:25
Modified
2024-09-16 18:29
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.2.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:22:09.299Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-02-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-06T20:25:14", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-02-20", "ID": "CVE-2020-5328", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.0" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur." } ] }, "impact": { "cvss": { "baseScore": 9.8, "baseSeverity": "Critical", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5328", "datePublished": "2020-03-06T20:25:14.219804Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T18:29:46.134Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5353
Vulnerability from cvelistv5
Published
2021-07-29 15:55
Modified
2024-09-17 00:27
Severity ?
EPSS score ?
Summary
The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an 'admin' home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system.
References
▼ | URL | Tags |
---|---|---|
https://support.emc.com/kb/542721 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < All supported |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.439Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support.emc.com/kb/542721" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "All supported", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-04-09T00:00:00", "descriptions": [ { "lang": "en", "value": "The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-29T15:55:15", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support.emc.com/kb/542721" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-04-09", "ID": "CVE-2020-5353", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "All supported" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.emc.com/kb/542721", "refsource": "MISC", "url": "https://support.emc.com/kb/542721" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5353", "datePublished": "2021-07-29T15:55:15.791310Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-17T00:27:01.594Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5364
Vulnerability from cvelistv5
Published
2020-05-20 20:45
Modified
2024-09-16 19:10
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions 8.2.2 and earlier contain an SNMPv2 vulnerability. The SNMPv2 services is enabled, by default, with a pre-configured community string. This community string allows read-only access to many aspects of the Isilon cluster, some of which are considered sensitive and can foster additional access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.683Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-05-15T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier contain an SNMPv2 vulnerability. The SNMPv2 services is enabled, by default, with a pre-configured community string. This community string allows read-only access to many aspects of the Isilon cluster, some of which are considered sensitive and can foster additional access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-201", "description": "CWE-201: Exposure of Sensitive Information Through Sent Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-05-20T20:45:18", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-05-15", "ID": "CVE-2020-5364", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier contain an SNMPv2 vulnerability. The SNMPv2 services is enabled, by default, with a pre-configured community string. This community string allows read-only access to many aspects of the Isilon cluster, some of which are considered sensitive and can foster additional access." } ] }, "impact": { "cvss": { "baseScore": 5.3, "baseSeverity": "Medium", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-201: Exposure of Sensitive Information Through Sent Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5364", "datePublished": "2020-05-20T20:45:18.127497Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T19:10:16.543Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5365
Vulnerability from cvelistv5
Published
2020-05-20 20:45
Modified
2024-09-16 17:17
Severity ?
EPSS score ?
Summary
Dell EMC Isilon versions 8.2.2 and earlier contain a remotesupport vulnerability. The pre-configured support account, remotesupport, is bundled in the Dell EMC Isilon OneFS installation. This account is used for diagnostics and other support functions. Although the default password is different for every cluster, it is predictable.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.432Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-05-15T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon versions 8.2.2 and earlier contain a remotesupport vulnerability. The pre-configured support account, remotesupport, is bundled in the Dell EMC Isilon OneFS installation. This account is used for diagnostics and other support functions. Although the default password is different for every cluster, it is predictable." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-341", "description": "CWE-341: Predictable from Observable State", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-05-20T20:45:18", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-05-15", "ID": "CVE-2020-5365", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon versions 8.2.2 and earlier contain a remotesupport vulnerability. The pre-configured support account, remotesupport, is bundled in the Dell EMC Isilon OneFS installation. This account is used for diagnostics and other support functions. Although the default password is different for every cluster, it is predictable." } ] }, "impact": { "cvss": { "baseScore": 5.3, "baseSeverity": "Medium", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-341: Predictable from Observable State" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/543775/DSA-2020-124-Dell-EMC-Isilon-OneFS-Security-Update-for-Multiple-Vulnerabilities" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5365", "datePublished": "2020-05-20T20:45:18.564948Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T17:17:39.870Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5318
Vulnerability from cvelistv5
Published
2020-02-06 17:45
Modified
2024-09-16 20:32
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions 8.1.2, 8.1.0.4, 8.1.0.3, and 8.0.0.7 contain a vulnerability in some configurations. An attacker may exploit this vulnerability to gain access to restricted files. The non-RAN HTTP and WebDAV file-serving components have a vulnerability wherein when either are enabled, and Basic Authentication is enabled for either or both components, files are accessible without authentication.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: 8.1.2, 8.1.0.4, 8.1.0.3, 8.0.0.7 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:22:09.254Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/540708/DSA-2020-018-Dell-EMC-Isilon-OneFS-Security-Update-for-Improper-Authorization-Vulnerability" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "status": "affected", "version": "8.1.2, 8.1.0.4, 8.1.0.3, 8.0.0.7" } ] } ], "datePublic": "2020-01-29T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions 8.1.2, 8.1.0.4, 8.1.0.3, and 8.0.0.7 contain a vulnerability in some configurations. An attacker may exploit this vulnerability to gain access to restricted files. The non-RAN HTTP and WebDAV file-serving components have a vulnerability wherein when either are enabled, and Basic Authentication is enabled for either or both components, files are accessible without authentication." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-06T17:45:21", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/540708/DSA-2020-018-Dell-EMC-Isilon-OneFS-Security-Update-for-Improper-Authorization-Vulnerability" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-01-29", "ID": "CVE-2020-5318", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "=", "version_value": "8.1.2, 8.1.0.4, 8.1.0.3, 8.0.0.7" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions 8.1.2, 8.1.0.4, 8.1.0.3, and 8.0.0.7 contain a vulnerability in some configurations. An attacker may exploit this vulnerability to gain access to restricted files. The non-RAN HTTP and WebDAV file-serving components have a vulnerability wherein when either are enabled, and Basic Authentication is enabled for either or both components, files are accessible without authentication." } ] }, "impact": { "cvss": { "baseScore": 7.5, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/540708/DSA-2020-018-Dell-EMC-Isilon-OneFS-Security-Update-for-Improper-Authorization-Vulnerability", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/540708/DSA-2020-018-Dell-EMC-Isilon-OneFS-Security-Update-for-Improper-Authorization-Vulnerability" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5318", "datePublished": "2020-02-06T17:45:21.769450Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T20:32:51.816Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5383
Vulnerability from cvelistv5
Published
2020-08-27 18:25
Modified
2024-09-16 22:46
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS version 8.2.2 and Dell EMC PowerScale OneFS version 9.0.0 contains a buffer overflow vulnerability in the Likewise component. A remote unauthenticated malicious attacker may potentially exploit this vulnerability to cause a process restart.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: unspecified < 9.0.0.0, 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.957Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/546005/DSA-2020-189-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-Buffer-Overflow-Vu" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "9.0.0.0, 8.2.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-08-24T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS version 8.2.2 and Dell EMC PowerScale OneFS version 9.0.0 contains a buffer overflow vulnerability in the Likewise component. A remote unauthenticated malicious attacker may potentially exploit this vulnerability to cause a process restart." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-08-27T18:25:11", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/546005/DSA-2020-189-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-Buffer-Overflow-Vu" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-08-24", "ID": "CVE-2020-5383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "9.0.0.0, 8.2.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS version 8.2.2 and Dell EMC PowerScale OneFS version 9.0.0 contains a buffer overflow vulnerability in the Likewise component. A remote unauthenticated malicious attacker may potentially exploit this vulnerability to cause a process restart." } ] }, "impact": { "cvss": { "baseScore": 5.3, "baseSeverity": "Medium", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/546005/DSA-2020-189-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-Buffer-Overflow-Vu", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/546005/DSA-2020-189-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-Buffer-Overflow-Vu" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5383", "datePublished": "2020-08-27T18:25:11.098840Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T22:46:50.183Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5371
Vulnerability from cvelistv5
Published
2020-07-06 17:45
Modified
2024-09-16 19:52
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale version 9.0.0 contain a file permissions vulnerability. An attacker, with network or local file access, could take advantage of insufficiently applied file permissions or gain unauthorized access to files.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Isilon OneFS |
Version: 8.1.2, 8.2.1, 8.2.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:24.227Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/544593/DSA-2020-155-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-a-Permissions-Vuln" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "status": "affected", "version": "8.1.2, 8.2.1, 8.2.2" } ] } ], "datePublic": "2020-06-18T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale version 9.0.0 contain a file permissions vulnerability. An attacker, with network or local file access, could take advantage of insufficiently applied file permissions or gain unauthorized access to files." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-06T17:45:18", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/544593/DSA-2020-155-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-a-Permissions-Vuln" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-06-18", "ID": "CVE-2020-5371", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "=", "version_value": "8.1.2, 8.2.1, 8.2.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale version 9.0.0 contain a file permissions vulnerability. An attacker, with network or local file access, could take advantage of insufficiently applied file permissions or gain unauthorized access to files." } ] }, "impact": { "cvss": { "baseScore": 8, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-732: Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/544593/DSA-2020-155-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-a-Permissions-Vuln", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/544593/DSA-2020-155-Dell-EMC-Isilon-OneFS-and-Dell-EMC-PowerScale-Security-Update-for-a-Permissions-Vuln" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5371", "datePublished": "2020-07-06T17:45:18.792486Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T19:52:24.613Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }