Search criteria
24 vulnerabilities found for c-bus_toolkit by schneider-electric
FKIE_CVE-2023-5402
Vulnerability from fkie_nvd - Published: 2023-10-04 18:15 - Updated: 2024-11-21 08:41
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote
code execution when the transfer command is used over the network.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93758686-7EEE-462D-80FE-D5AFA520DD8A",
"versionEndIncluding": "1.16.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
},
{
"lang": "es",
"value": "CWE-269: Existe una vulnerabilidad de gesti\u00f3n de privilegios inadecuada, que podr\u00eda provocar una ejecuci\u00f3n remota de c\u00f3digo cuando se utiliza el comando de transferencia a trav\u00e9s de la red."
}
],
"id": "CVE-2023-5402",
"lastModified": "2024-11-21T08:41:42.097",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-10-04T18:15:12.240",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22748
Vulnerability from fkie_nvd - Published: 2022-02-11 18:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D31B2753-D253-41E3-9582-8E517A1D40EE",
"versionEndIncluding": "1.15.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido (\"Path Traversal\") que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo remota cuando es guardado un archivo. Producto afectado: C-Bus Toolkit (versiones V1.15.9 y anteriores), C-Gate Server (versiones V2.11.7 y anteriores)"
}
],
"id": "CVE-2021-22748",
"lastModified": "2024-11-21T05:50:35.290",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-11T18:15:08.897",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22784
Vulnerability from fkie_nvd - Published: 2021-07-21 15:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04 | Product, Vendor Advisory | |
| cybersecurity@se.com | https://www.tenable.com/security/research/tra-2021-50 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04 | Product, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-50 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3B18E52F-DE56-4B3B-8E11-52DC57650C38",
"versionEndExcluding": "1.15.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."
},
{
"lang": "es",
"value": "A CWE-306: Se presenta una vulnerabilidad de Falta de Autentificaci\u00f3n para una Funci\u00f3n Cr\u00edtica en C-Bus Toolkit versiones v1.15.8 y anteriores, que podr\u00eda permitir a un atacante usar una p\u00e1gina web dise\u00f1ada para obtener acceso remoto al sistema"
}
],
"id": "CVE-2021-22784",
"lastModified": "2024-11-21T05:50:39.650",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-21T15:15:15.377",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Product",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22716
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:50
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56",
"versionEndIncluding": "1.15.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"
},
{
"lang": "es",
"value": "Una CWE-732: Asignaci\u00f3n incorrecta de permisos para recursos cr\u00edticos que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)"
}
],
"id": "CVE-2021-22716",
"lastModified": "2024-11-21T05:50:31.200",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.210",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"source": "cybersecurity@se.com",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-22718
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-448/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-448/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56",
"versionEndIncluding": "1.15.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files."
},
{
"lang": "es",
"value": "Una CWE-22: se presenta una vulnerabilidad Limitaci\u00f3n Inapropiada de un Nombre de Ruta para un Directorio Restringido (\"Path Traversal\") en C-Bus Toolkit (versiones V1.15.7 y anteriores) que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo remota al restaurar archivos de proyecto"
}
],
"id": "CVE-2021-22718",
"lastModified": "2024-11-21T05:50:31.437",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.383",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22720
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| cybersecurity@se.com | https://www.tenable.com/security/research/tra-2021-50 | Exploit, Third Party Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-450/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-50 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-450/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56",
"versionEndIncluding": "1.15.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project."
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta para un Directorio Restringido (\"Path Traversal\") en C-Bus Toolkit (versiones V1.15.7 y anteriores) que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo remota al restaurar un proyecto"
}
],
"id": "CVE-2021-22720",
"lastModified": "2024-11-21T05:50:31.673",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.523",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22717
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-447/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-447/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56",
"versionEndIncluding": "1.15.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta para un Directorio Restringido (\"Path Traversal\") en C-Bus Toolkit (versiones V1.15.7 y anteriores) que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo remota al procesar archivos de configuraci\u00f3n"
}
],
"id": "CVE-2021-22717",
"lastModified": "2024-11-21T05:50:31.323",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.303",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2021-22719
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-449/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-449/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | c-bus_toolkit | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0CC2C60-78DD-4959-B70F-CF0A3073FC56",
"versionEndIncluding": "1.15.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded."
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta para un Directorio Restringido (\"Path Traversal\") en C-Bus Toolkit (versiones V1.15.7 y anteriores) que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo remota cuando se carga un archivo"
}
],
"id": "CVE-2021-22719",
"lastModified": "2024-11-21T05:50:31.553",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.460",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
CVE-2023-5402 (GCVE-0-2023-5402)
Vulnerability from cvelistv5 – Published: 2023-10-04 17:59 – Updated: 2025-02-27 20:46
VLAI?
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote
code execution when the transfer command is used over the network.
Severity ?
9.8 (Critical)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
v1.16.3 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:47.338346Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:53.296Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v1.16.3 and prior "
}
]
}
],
"datePublic": "2023-10-10T17:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"value": "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T08:14:27.514Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5402",
"datePublished": "2023-10-04T17:59:59.273Z",
"dateReserved": "2023-10-04T17:50:52.167Z",
"dateUpdated": "2025-02-27T20:46:53.296Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22748 (GCVE-0-2021-22748)
Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior) |
Affected:
C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-11T17:40:29",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22748",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22748",
"datePublished": "2022-02-11T17:40:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22784 (GCVE-0-2021-22784)
Vulnerability from cvelistv5 – Published: 2021-07-21 10:40 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
Severity ?
No CVSS data available.
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit v1.15.8 and prior |
Affected:
C-Bus Toolkit v1.15.8 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit v1.15.8 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit v1.15.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T00:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22784",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit v1.15.8 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit v1.15.8 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"name": "https://www.tenable.com/security/research/tra-2021-50",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22784",
"datePublished": "2021-07-21T10:40:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.452Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22720 (GCVE-0-2021-22720)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:32 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.099Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T00:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22720",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"name": "https://www.tenable.com/security/research/tra-2021-50",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22720",
"datePublished": "2021-04-13T18:32:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22719 (GCVE-0-2021-22719)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:32 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.234Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T15:06:20",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22719",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22719",
"datePublished": "2021-04-13T18:32:12",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22718 (GCVE-0-2021-22718)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:31 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T14:06:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22718",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22718",
"datePublished": "2021-04-13T18:31:49",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.512Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22717 (GCVE-0-2021-22717)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:31 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T14:06:17",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22717",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22717",
"datePublished": "2021-04-13T18:31:31",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22716 (GCVE-0-2021-22716)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:31 – Updated: 2024-09-16 22:02
VLAI?
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
Severity ?
7.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
V , < 1.15.9
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:06.795Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "1.15.9",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-18T00:00:00",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22716",
"datePublished": "2021-04-13T18:31:18.018125Z",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-09-16T22:02:57.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5402 (GCVE-0-2023-5402)
Vulnerability from nvd – Published: 2023-10-04 17:59 – Updated: 2025-02-27 20:46
VLAI?
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote
code execution when the transfer command is used over the network.
Severity ?
9.8 (Critical)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
v1.16.3 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:47.338346Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:53.296Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v1.16.3 and prior "
}
]
}
],
"datePublic": "2023-10-10T17:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"value": "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T08:14:27.514Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5402",
"datePublished": "2023-10-04T17:59:59.273Z",
"dateReserved": "2023-10-04T17:50:52.167Z",
"dateUpdated": "2025-02-27T20:46:53.296Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22748 (GCVE-0-2021-22748)
Vulnerability from nvd – Published: 2022-02-11 17:40 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior) |
Affected:
C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-11T17:40:29",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22748",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22748",
"datePublished": "2022-02-11T17:40:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22784 (GCVE-0-2021-22784)
Vulnerability from nvd – Published: 2021-07-21 10:40 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
Severity ?
No CVSS data available.
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit v1.15.8 and prior |
Affected:
C-Bus Toolkit v1.15.8 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.452Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit v1.15.8 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit v1.15.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T00:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22784",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit v1.15.8 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit v1.15.8 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-04"
},
{
"name": "https://www.tenable.com/security/research/tra-2021-50",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22784",
"datePublished": "2021-07-21T10:40:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.452Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22720 (GCVE-0-2021-22720)
Vulnerability from nvd – Published: 2021-04-13 18:32 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.099Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-17T00:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22720",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-450/"
},
{
"name": "https://www.tenable.com/security/research/tra-2021-50",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-50"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22720",
"datePublished": "2021-04-13T18:32:29",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22719 (GCVE-0-2021-22719)
Vulnerability from nvd – Published: 2021-04-13 18:32 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.234Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T15:06:20",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22719",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-449/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22719",
"datePublished": "2021-04-13T18:32:12",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22718 (GCVE-0-2021-22718)
Vulnerability from nvd – Published: 2021-04-13 18:31 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T14:06:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22718",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-448/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22718",
"datePublished": "2021-04-13T18:31:49",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.512Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22717 (GCVE-0-2021-22717)
Vulnerability from nvd – Published: 2021-04-13 18:31 – Updated: 2024-08-03 18:51
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
Severity ?
No CVSS data available.
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | C-Bus Toolkit V1.15.7 and prior |
Affected:
C-Bus Toolkit V1.15.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit V1.15.7 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T14:06:17",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22717",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "C-Bus Toolkit V1.15.7 and prior",
"version": {
"version_data": [
{
"version_value": "C-Bus Toolkit V1.15.7 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-447/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22717",
"datePublished": "2021-04-13T18:31:31",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22716 (GCVE-0-2021-22716)
Vulnerability from nvd – Published: 2021-04-13 18:31 – Updated: 2024-09-16 22:02
VLAI?
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
Severity ?
7.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
V , < 1.15.9
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:06.795Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "1.15.9",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-18T00:00:00",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22716",
"datePublished": "2021-04-13T18:31:18.018125Z",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-09-16T22:02:57.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}