cve-2023-5402
Vulnerability from cvelistv5
Published
2023-10-04 17:59
Modified
2024-08-02 07:59
Severity ?
EPSS score ?
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote
code execution when the transfer command is used over the network.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | C-Bus Toolkit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:59:44.294Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "C-Bus Toolkit", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v1.16.3 and prior " } ] } ], "datePublic": "2023-10-10T17:55:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n" } ], "value": "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-269", "description": "CWE-269 Improper Privilege Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-11T08:14:27.514Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5402", "datePublished": "2023-10-04T17:59:59.273Z", "dateReserved": "2023-10-04T17:50:52.167Z", "dateUpdated": "2024-08-02T07:59:44.294Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-5402\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-10-04T18:15:12.240\",\"lastModified\":\"2023-10-11T19:19:54.037\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\\ncode execution when the transfer command is used over the network.\\n\\n\"},{\"lang\":\"es\",\"value\":\"CWE-269: Existe una vulnerabilidad de gesti\u00f3n de privilegios inadecuada, que podr\u00eda provocar una ejecuci\u00f3n remota de c\u00f3digo cuando se utiliza el comando de transferencia a trav\u00e9s de la red.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.16.3\",\"matchCriteriaId\":\"93758686-7EEE-462D-80FE-D5AFA520DD8A\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.