Vulnerabilites related to siemens - simatic_cp_1243-1_iec_firmware
CVE-2022-43716 (GCVE-0-2022-43716)
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2024-09-10 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
References
Impacted products
{ containers: { adp: [ { affected: [ { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_443-1", vendor: "siemens", versions: [ { lessThan: "v3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_443-1", vendor: "siemens", versions: [ { lessThan: "v3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_443-1_advanced", vendor: "siemens", versions: [ { lessThan: "v3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1242-7_gprs_v2", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1_dnp3", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1_iec", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-7_lte_eu", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-7_lte_us", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-8", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1542sp-1", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1542sp-1_irc", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1543sp-1", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1542sp-1_irc_tx_rail", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1543sp-1_isec", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1543sp-1_isec_tx_rail", vendor: "siemens", versions: [ { lessThan: "v2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_443-1_advanced", vendor: "siemens", versions: [ { lessThan: "v3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_1242-7_v2", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_s7-1200_cp_1243-1", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_s7-1200_cp_1243-1_rail", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_tim_1531_irc", vendor: "siemens", versions: [ { lessThan: "v2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_tim_1531_irc", vendor: "siemens", versions: [ { lessThan: "v2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, ], metrics: [ { other: { content: { id: "CVE-2022-43716", options: [ { Exploitation: "none", }, { Automatable: "yes", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-07-09T14:12:55.560896Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-07-09T14:35:43.227Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-03T13:40:06.265Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE EU", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE US", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-416", description: "CWE-416: Use After Free", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:31.854Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-43716", datePublished: "2023-04-11T09:02:49.383Z", dateReserved: "2022-10-24T05:19:12.272Z", dateUpdated: "2024-09-10T09:33:31.854Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2022-43768 (GCVE-0-2022-43768)
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2025-02-07 16:51
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 |
Version: 0 < V3.4.29 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T13:40:06.422Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], title: "CVE Program Container", }, { metrics: [ { other: { content: { id: "CVE-2022-43768", options: [ { Exploitation: "none", }, { Automatable: "yes", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2025-02-07T16:50:58.868618Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2025-02-07T16:51:07.850Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE EU", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE US", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-770", description: "CWE-770: Allocation of Resources Without Limits or Throttling", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:34.861Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-43768", datePublished: "2023-04-11T09:02:51.623Z", dateReserved: "2022-10-26T11:27:16.347Z", dateUpdated: "2025-02-07T16:51:07.850Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from cvelistv5
Published
2017-05-11 01:00
Modified
2024-09-10 09:33
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_CONFIRM | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { metrics: [ { other: { content: { id: "CVE-2017-2680", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-07-09T13:26:04.237652Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-07-09T13:26:15.327Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-05T14:02:07.270Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "1038463", tags: [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred", ], url: "http://www.securitytracker.com/id/1038463", }, { name: "98369", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/98369", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-284673.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-546832.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.1 Patch04", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1 Patch03", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4.0 Patch01", }, ], }, { defaultStatus: "unknown", product: "Extension Unit 12\" PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V01.01.01", }, ], }, { defaultStatus: "unknown", product: "Extension Unit 15\" PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V01.01.01", }, ], }, { defaultStatus: "unknown", product: "Extension Unit 19\" PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V01.01.01", }, ], }, { defaultStatus: "unknown", product: "Extension Unit 22\" PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V01.01.01", }, ], }, { defaultStatus: "unknown", product: "IE/AS-i Link PN IO", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "IE/PB-Link (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.03", }, ], }, { defaultStatus: "unknown", product: "SCALANCE W-700 IEEE 802.11n family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-200 family (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.2.2", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.4.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X408 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X414", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.10.2", }, ], }, { defaultStatus: "unknown", product: "SCALANCE XM-400 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SCALANCE XR-500 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CM 1542-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CM 1542SP-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE US", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1604", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1616", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1626", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 OPC UA", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC DK-16xx PN IO", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200AL IM 157-1 PN", vendor: "Siemens", versions: [ { lessThan: "V1.0.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200M (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN BA", vendor: "Siemens", versions: [ { lessThan: "V4.0.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-3 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-4 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HS", vendor: "Siemens", versions: [ { lessThan: "V4.0.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 4AO U/I 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN: IO-Link Master", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200S (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-B", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-B Body", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-P", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-P Body", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 HR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 SR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 UR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF650R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF680R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF685R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 Software Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-200 SMART", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.X.14", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V6.0.7", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V6.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V7.0.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V8.2", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CP51M1", vendor: "Siemens", versions: [ { lessThan: "V1.1.8", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CPU555", vendor: "Siemens", versions: [ { lessThan: "V1.1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Basic", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Standard", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX F 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0.0", }, ], }, { defaultStatus: "unknown", product: "SIMOTION", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 HF1", }, ], }, { defaultStatus: "unknown", product: "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4 HF26", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCM w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.4 SP1 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCP w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.2 HF1", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G110M w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP6 HF3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP6 HF3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "V4.7: All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GH150 V4.7 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP5 HF7", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GL150 V4.7 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GM150 V4.7 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF31", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S110 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4 SP3 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7.0 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF30", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7.4 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7.5 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM120 V4.7 w. PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2", }, ], }, { defaultStatus: "unknown", product: "SINAMICS V90 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.01", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D V4.5 and prior", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 SP6 HF2", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D V4.7", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP4 HF1", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl V4.5 and prior", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 SP6 HF2", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl V4.7", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP4 HF1", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIRIUS ACT 3SU1 interface module PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { defaultStatus: "unknown", product: "SIRIUS Motor Starter M200D PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIRIUS Soft Starter 3RW44 PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SITOP PSU8600 PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.2.0", }, ], }, { defaultStatus: "unknown", product: "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.2.0", }, ], }, { defaultStatus: "unknown", product: "Softnet PROFINET IO for PC-based Windows systems", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14 SP1", }, ], }, ], descriptions: [ { lang: "en", value: "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.", }, ], metrics: [ { cvssV3_1: { baseScore: 6.5, baseSeverity: "MEDIUM", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, }, { cvssV4_0: { baseScore: 7.1, baseSeverity: "HIGH", vectorString: "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", version: "4.0", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-400", description: "CWE-400: Uncontrolled Resource Consumption", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:18.492Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "1038463", tags: [ "vdb-entry", "x_refsource_SECTRACK", ], url: "http://www.securitytracker.com/id/1038463", }, { name: "98369", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/98369", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-284673.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-546832.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2017-2680", datePublished: "2017-05-11T01:00:00", dateReserved: "2016-12-01T00:00:00", dateUpdated: "2024-09-10T09:33:18.492Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2022-43767 (GCVE-0-2022-43767)
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2024-09-10 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 |
Version: 0 < V3.4.29 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { affected: [ { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1542sp-1", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1542sp-1_irc", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1543sp-1", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_443-1", vendor: "siemens", versions: [ { lessThan: "3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_443-1_advanced", vendor: "siemens", versions: [ { lessThan: "3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1542sp-1_irc_tx_rail", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1543sp-1_isec", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_et_200sp_cp_1543sp-1_isec_tx_rail", vendor: "siemens", versions: [ { lessThan: "2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_1242-7_v2", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_443-1", vendor: "siemens", versions: [ { lessThan: "3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_net_cp_443-1_advanced", vendor: "siemens", versions: [ { lessThan: "3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_s7-1200_cp_1243-1", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1242-7_v2", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1_dnp3", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-1_iec", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-7_lte_eu", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-7_lte_us", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cp_1243-8_irc", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_s7-1200_cp_1243-1_rail", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_tim_1531_irc", vendor: "siemens", versions: [ { lessThan: "2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "tim_1531_irc", vendor: "siemens", versions: [ { lessThan: "2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, ], metrics: [ { other: { content: { id: "CVE-2022-43767", options: [ { Exploitation: "none", }, { Automatable: "yes", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-07-12T19:11:06.737320Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-07-12T20:11:32.129Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-03T13:40:06.317Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE EU", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE US", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 1242-7 V2", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1 Advanced", vendor: "Siemens", versions: [ { lessThan: "V3.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-1200 CP 1243-1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "TIM 1531 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3.6", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-833", description: "CWE-833: Deadlock", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:33.351Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-43767", datePublished: "2023-04-11T09:02:50.497Z", dateReserved: "2022-10-26T11:27:16.347Z", dateUpdated: "2024-09-10T09:33:33.351Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2017-2681 (GCVE-0-2017-2681)
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-09-10 09:33
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { metrics: [ { other: { content: { id: "CVE-2017-2681", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-07-23T20:22:19.045364Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-07-23T20:22:26.181Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-05T14:02:07.386Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "1038463", tags: [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred", ], url: "http://www.securitytracker.com/id/1038463", }, { name: "98369", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/98369", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.1 Patch04", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1 Patch03", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4.0 Patch01", }, ], }, { defaultStatus: "unknown", product: "IE/AS-i Link PN IO", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "IE/PB-Link (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.03", }, ], }, { defaultStatus: "unknown", product: "SCALANCE W-700 IEEE 802.11n family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-200 family (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.2.2", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.4.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X408 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X414", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.10.2", }, ], }, { defaultStatus: "unknown", product: "SCALANCE XM-400 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SCALANCE XR-500 family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V6.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CM 1542-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CM 1542SP-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.82", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0.15", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1604", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1616", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 OPC UA", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC DK-16xx PN IO", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200AL IM 157-1 PN", vendor: "Siemens", versions: [ { lessThan: "V1.0.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200M (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN BA", vendor: "Siemens", versions: [ { lessThan: "V4.0.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-3 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-4 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HS", vendor: "Siemens", versions: [ { lessThan: "V4.0.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 4AO U/I 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN: IO-Link Master", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200S (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-B", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-B Body", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-P", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV420 SR-P Body", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 HR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 SR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC MV440 UR", vendor: "Siemens", versions: [ { lessThan: "V7.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF650R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF680R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF685R", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 Software Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-200 SMART", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.X.14", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V6.0.7", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V6.0.6", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V7.0.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V8.2", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CP51M1", vendor: "Siemens", versions: [ { lessThan: "V1.1.8", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CPU555", vendor: "Siemens", versions: [ { lessThan: "V1.1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Basic", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Standard", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX F 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0.0", }, ], }, { defaultStatus: "unknown", product: "SIMOTION", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 HF1", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCM w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.4 SP1 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCP w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.2 HF1", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G110M w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP6 HF3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP6 HF3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "V4.7: All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S110 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4 SP3 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.7 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF27", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.8 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS V90 w. PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.01", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D V4.5 and prior", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 SP6 HF2", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D V4.7", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP4 HF1", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl V4.5 and prior", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5 SP6 HF2", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl V4.7", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP4 HF1", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIRIUS ACT 3SU1 interface module PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { defaultStatus: "unknown", product: "SIRIUS Motor Starter M200D PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIRIUS Soft Starter 3RW44 PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SITOP PSU8600 PROFINET", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.2.0", }, ], }, { defaultStatus: "unknown", product: "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.2.0", }, ], }, { defaultStatus: "unknown", product: "Softnet PROFINET IO for PC-based Windows systems", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14 SP1", }, ], }, ], descriptions: [ { lang: "en", value: "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.", }, ], metrics: [ { cvssV3_1: { baseScore: 6.5, baseSeverity: "MEDIUM", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, }, { cvssV4_0: { baseScore: 7.1, baseSeverity: "HIGH", vectorString: "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", version: "4.0", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-400", description: "CWE-400: Uncontrolled Resource Consumption", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:20.658Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "1038463", tags: [ "vdb-entry", "x_refsource_SECTRACK", ], url: "http://www.securitytracker.com/id/1038463", }, { name: "98369", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/98369", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2017-2681", datePublished: "2017-05-11T10:00:00", dateReserved: "2016-12-01T00:00:00", dateUpdated: "2024-09-10T09:33:20.658Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2023-38380 (GCVE-0-2023-38380)
Vulnerability from cvelistv5
Published
2023-12-12 11:26
Modified
2024-08-02 17:39
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.
An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.4.29 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-02T17:39:13.213Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-693975.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-625862.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-7 LTE", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1243-8 IRC", vendor: "Siemens", versions: [ { lessThan: "V3.4.29", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1542SP-1 IRC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543-1", vendor: "Siemens", versions: [ { lessThan: "V3.0.37", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1543SP-1", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S210 (6SL5...)", vendor: "Siemens", versions: [ { lessThan: "V6.1 HF2", status: "affected", version: "V6.1", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V2.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 1543-1", vendor: "Siemens", versions: [ { lessThan: "V3.0.37", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, { cvssV4_0: { baseScore: 8.7, baseSeverity: "HIGH", vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", version: "4.0", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-401", description: "CWE-401: Missing Release of Memory after Effective Lifetime", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-06-11T14:19:50.234Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-693975.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-625862.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2023-38380", datePublished: "2023-12-12T11:26:36.173Z", dateReserved: "2023-07-17T13:06:36.758Z", dateUpdated: "2024-08-02T17:39:13.213Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_1242-7_v2_firmware | * | |
siemens | simatic_cp_1242-7_v2 | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-7_lte_eu_firmware | * | |
siemens | simatic_cp_1243-7_lte_eu | - | |
siemens | simatic_cp_1243-7_lte_us_firmware | * | |
siemens | simatic_cp_1243-7_lte_us | - | |
siemens | simatic_cp_1243-8_irc_firmware | * | |
siemens | simatic_cp_1243-8_irc | - | |
siemens | simatic_cp_1542sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_443-1_firmware | * | |
siemens | simatic_cp_443-1 | - | |
siemens | simatic_cp_443-1_advanced_firmware | * | |
siemens | simatic_cp_443-1_advanced | - | |
siemens | simatic_ipc_diagbase_firmware | * | |
siemens | simatic_ipc_diagbase | - | |
siemens | simatic_ipc_diagmonitor_firmware | * | |
siemens | simatic_ipc_diagmonitor | - | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail | - | |
siemens | siplus_net_cp_1242-7_v2_firmware | * | |
siemens | siplus_net_cp_1242-7_v2 | - | |
siemens | siplus_net_cp_443-1_firmware | * | |
siemens | siplus_net_cp_443-1 | - | |
siemens | siplus_net_cp_443-1_advanced_firmware | * | |
siemens | siplus_net_cp_443-1_advanced | - | |
siemens | siplus_s7-1200_cp_1243-1_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1 | - | |
siemens | siplus_s7-1200_cp_1243-1_rail_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1_rail | - | |
siemens | siplus_tim_1531_irc_firmware | * | |
siemens | siplus_tim_1531_irc | - | |
siemens | tim_1531_irc_firmware | * | |
siemens | tim_1531_irc | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "840C5C25-1E34-42FA-8221-7232622C204F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "29D4C72C-4E84-4563-9D66-5C641AB996BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FE3D7928-8E1A-400E-B790-58D6F5938E3C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BE5003DA-5488-47C1-B442-9137E849FDD5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "93D43BC6-EDE3-4EE1-9410-4717EB641AD0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*", matchCriteriaId: "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "786F3FFD-87E4-45B9-A33C-BAE58379FF39", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*", matchCriteriaId: "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "12A45F37-1E7D-4748-ADAC-EC4C454B693A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C1F51B86-57EE-4DB6-B038-06726BC93D2D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8648EF79-043D-48DE-B9F8-BF762862EE99", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C8B5C37-200C-4531-8876-3E05F3DE3EC8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "843A8686-5172-4782-BB97-B5D3C6FB27A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BCDA714C-5851-4E35-806F-E0C651A1E87A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F58423D0-954E-426E-9F8F-3DD95FBDF50C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "530FD06D-E020-4EB3-87DD-F7B2FEE58008", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*", matchCriteriaId: "8784BA58-12BF-4F1C-94D6-2D15933703C8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "91371CD0-EBDF-43C5-A262-A46E1C343716", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*", matchCriteriaId: "A5E06833-4C26-40AC-B6CF-F7D1322462D6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AE009635-7EC7-4A2F-B1FA-DD75213A25CA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9054A7B6-9569-4D65-9695-A0FFA4F56C74", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*", matchCriteriaId: "A60FC550-A518-46BF-9124-E21DD654981C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4F488C27-C8B9-4238-8409-AB7ACA3BC849", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7FE26E32-47C0-4976-A23A-07C1AE318C35", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "116E84DA-31F7-4AAC-A1AE-491C4C98BD49", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45B95689-C355-4CF1-AE7A-0860E4CEA11A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "21F04D79-5815-4D36-8AA5-4866751D0DDB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "2498071A-6540-4147-8D01-3B81A5CE9A57", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F9E746CF-4009-4A14-8916-A9E0276CAF8B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "4A294530-727C-4535-8B02-668DF74587D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2C616E50-1F96-4A87-8470-1BA8732FCB77", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "074FDC9C-CB36-4C67-82C8-1B930FF1269F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "C1D94BEB-BBFB-4258-9835-87DBBB999239", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.", }, ], id: "CVE-2022-43768", lastModified: "2024-11-21T07:27:11.733", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Primary", }, ], }, published: "2023-04-11T10:15:17.617", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-770", }, ], source: "productcert@siemens.com", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2017-05-11 10:29
Modified
2024-11-21 03:23
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_343-1_std_firmware | * | |
siemens | simatic_cp_343-1_std | - | |
siemens | simatic_cp_343-1_lean_firmware | * | |
siemens | simatic_cp_343-1_lean | - | |
siemens | simatic_cp_343-1_adv_firmware | * | |
siemens | simatic_cp_343-1_adv | - | |
siemens | simatic_cp_443-1_std_firmware | * | |
siemens | simatic_cp_443-1_std | - | |
siemens | simatic_cp_443-1_adv_firmware | * | |
siemens | simatic_cp_443-1_adv | - | |
siemens | simatic_cp_443-1_opc-ua_firmware | * | |
siemens | simatic_cp_443-1_opc-ua | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cm_1542-1_firmware | * | |
siemens | simatic_cm_1542-1 | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_1543-1_firmware | * | |
siemens | simatic_cp_1543-1 | - | |
siemens | simatic_rf650r_firmware | * | |
siemens | simatic_rf650r | - | |
siemens | simatic_rf680r_firmware | * | |
siemens | simatic_rf680r | - | |
siemens | simatic_rf685r_firmware | * | |
siemens | simatic_rf685r | - | |
siemens | simatic_cp_1616_firmware | * | |
siemens | simatic_cp_1616 | - | |
siemens | simatic_cp_1604_firmware | * | |
siemens | simatic_cp_1604 | - | |
siemens | simatic_dk-16xx_pn_io_firmware | * | |
siemens | simatic_dk-16xx_pn_io | - | |
siemens | scalance_x200_firmware | * | |
siemens | scalance_x200 | - | |
siemens | scalance_x200_irt_firmware | * | |
siemens | scalance_x200_irt | - | |
siemens | scalance_x300_firmware | * | |
siemens | scalance_x300 | - | |
siemens | scalance_x408_firmware | * | |
siemens | scalance_x408 | - | |
siemens | scalance_x414_firmware | * | |
siemens | scalance_x414 | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | softnet_profinet_io_firmware | * | |
siemens | softnet_profinet_io_firmware | 14 | |
siemens | softnet_profinet_io | - | |
siemens | ie\/pb-link_firmware | * | |
siemens | ie\/pb-link | - | |
siemens | ie\/as-i_link_pn_io_firmware | * | |
siemens | ie\/as-i_link_pn_io | - | |
siemens | simatic_teleservice_adapter_standard_modem_firmware | * | |
siemens | simatic_teleservice_adapter_standard_modem | - | |
siemens | simatic_teleservice_adapter_ie_basic_modem_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic_modem | - | |
siemens | simatic_teleservice_adapter_ie_advanced_modem_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced_modem | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | ups1600_profinet_firmware | * | |
siemens | ups1600_profinet | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_firmware | * | |
siemens | simatic_et_200mp | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_firmware | * | |
siemens | simatic_et_200sp | - | |
siemens | pn\/pn_coupler_firmware | * | |
siemens | pn\/pn_coupler | - | |
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200p_pn_io_firmware | * | |
siemens | ek-ertec_200p_pn_io_firmware | 4.4.0 | |
siemens | ek-ertec_200p_pn_io | - | |
siemens | ek-ertec_200_pn_io_firmware | * | |
siemens | ek-ertec_200_pn_io_firmware | 4.2.1 | |
siemens | ek-ertec_200_pn_io | - | |
siemens | simatic_s7-200_smart_firmware | * | |
siemens | simatic_s7-200_smart | - | |
siemens | simatic_s7-300_firmware | * | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_firmware | * | |
siemens | simatic_s7-400 | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | sirius_act_3su1_firmware | * | |
siemens | sirius_act_3su1 | - | |
siemens | sirius_soft_starter_3rw44_pn_firmware | * | |
siemens | sirius_soft_starter_3rw44_pn | - | |
siemens | sirius_motor_starter_m200d_profinet_firmware | * | |
siemens | sirius_motor_starter_m200d_profinet | - | |
siemens | simocode_pro_v_profinet_firmware | * | |
siemens | simocode_pro_v_profinet | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp_firmware | 1.2 | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120\(c\/p\/d\)_pn_firmware | * | |
siemens | sinamics_g120\(c\/p\/d\)_pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 4.7 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 4.7 | |
siemens | sinamics_g150 | - | |
siemens | sinamics_s110_pn_firmware | * | |
siemens | sinamics_s110_pn_firmware | 4.4 | |
siemens | sinamics_s110_pn | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 4.7 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 4.7 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_v90_pn_firmware | * | |
siemens | sinamics_v90_pn | - | |
siemens | simotion_firmware | * | |
siemens | simotion_firmware | 4.5 | |
siemens | simotion | - | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.5 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.5 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_hmi_comfort_panels | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_multi_panels | * | |
siemens | simatic_hmi_multi_panels | - | |
siemens | simatic_hmi_mobile_panels | * | |
siemens | simatic_hmi_mobile_panels | - | |
siemens | simatic_cp_1243-1_irc_firmware | * | |
siemens | simatic_cp_1243-1_irc | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cm_1542sp-1_firmware | * | |
siemens | simatic_cm_1542sp-1 | - | |
siemens | simatic_s7-1500_software_controller | * | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.7 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.7 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_tdc_cpu555_firmware | * | |
siemens | simatic_tdc_cpu555 | - | |
siemens | simatic_tdc_cp51m1_firmware | * | |
siemens | simatic_tdc_cp51m1 | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFF143FA-311E-4081-805F-BBDB72003556", versionEndExcluding: "3.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*", matchCriteriaId: "9C351559-6D8D-4EA8-87D6-83003844BD97", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A", versionEndExcluding: "3.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*", matchCriteriaId: "EE2A18E2-F88F-4DC1-81E9-AC836C85A248", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7E0622A2-C918-4062-938A-8736469F8286", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*", matchCriteriaId: "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481", versionEndExcluding: "3.2.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*", matchCriteriaId: "BB8C873A-25EB-4787-9F25-DC5852337093", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "58E4035F-02AB-4B6D-A9AF-556DBE021C30", versionEndExcluding: "3.2.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*", matchCriteriaId: "75013961-5B00-42E9-9061-CF2E9A4FC090", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*", matchCriteriaId: "977E97C8-959F-4146-8BFD-0FCF014B1534", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "EBE1A019-4BC4-4352-BA16-05629A20F89F", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*", matchCriteriaId: "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CA3E3782-7F36-4BC3-8D00-E1961E3105E3", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "496E9B17-BD29-4DE9-96B3-B23E3599C766", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "843A8686-5172-4782-BB97-B5D3C6FB27A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12F7A42E-4D63-4A2A-ABF6-CA08BB6C6234", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*", matchCriteriaId: "3FDE92FB-38C7-46E8-9208-BBD7872219D5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "37B4E3A9-FE27-4A31-A213-92B461A5C846", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*", matchCriteriaId: "C82C2C69-D983-4317-968B-D1855DF8AE43", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "177A6E55-8D64-4CB8-B366-AE272E715932", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*", matchCriteriaId: "450DE127-DFED-4799-B8EA-0F95028E4BC3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "72D14DB5-6132-4442-8AB2-3ECE89B1D47C", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*", matchCriteriaId: "63F70060-0090-4BD7-8BF6-769989879ACD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", matchCriteriaId: "CA074FBE-1C3E-4441-8C51-52B555B85D9F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0424AECD-68D5-45F1-9F55-B72CB4DFE39C", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", matchCriteriaId: "6304FA24-F194-4EE2-95F5-35D086F82C01", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "26113F2F-8C5E-471B-9E12-AA3B3860B5CF", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "CA0D867D-737F-4CEC-BAEA-9ADE0BA2303E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45008AE8-8386-4CBA-8C38-10C1A60150C2", versionEndExcluding: "5.2.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*", matchCriteriaId: "A59C91EA-5D1B-4970-8C36-BD76BA420B12", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7F61995A-2018-4DAA-9529-BADC145B267F", versionEndExcluding: "5.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*", matchCriteriaId: "CAF3DA7A-6B80-4F20-835F-BF071197D1B0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3", versionEndExcluding: "4.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*", matchCriteriaId: "E3F6299B-D7E3-4750-B016-7DCBC83C2287", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B8A4CF89-9DDA-4974-A886-CC0A912017F7", versionEndExcluding: "4.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*", matchCriteriaId: "47F713E4-4B75-476E-BC21-92CA10198AE9", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2CA7C987-779A-4B64-BFAC-73D54618AF04", versionEndExcluding: "3.10.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*", matchCriteriaId: "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", matchCriteriaId: "9FC408A8-903F-43A2-9D05-65AD4482FDBB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B9AF696-211F-4CAD-8A0E-402487E8DC50", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", matchCriteriaId: "080E722F-FCD4-4967-86EE-151ADC5702E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D8763BB9-5DDA-4817-BDA6-63983CD4BC67", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", matchCriteriaId: "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5", versionEndExcluding: "4.03", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", matchCriteriaId: "DFB9921A-5204-40A3-88AB-B7755F5C6875", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE", versionEndExcluding: "4.03", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", matchCriteriaId: "E917CBBB-EF41-4113-B0CA-EB91889235E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9831567D-6528-4ACA-99F9-1EC42CB4A90D", versionEndExcluding: "14", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*", matchCriteriaId: "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*", matchCriteriaId: "E348069A-B809-4DF6-81E9-DC52C6E2C268", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8ED91175-0AF3-424A-8C49-43587BB95EAB", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*", matchCriteriaId: "8D43C16C-0719-4648-903F-6CC0FFF1835A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7E909C1E-9329-4459-ACE3-AD906CD4A968", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "317863B6-0B71-4D03-83FE-FC59EBB5307C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9F37323-B072-470B-B770-9735B84CACFE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*", matchCriteriaId: "610DF0CA-D0FA-4CBE-8383-6F038E7AC4C3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B366E4A-4223-4A42-9A05-52EB23BCF209", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*", matchCriteriaId: "98FB86B6-DB8A-42EF-BA60-68D96B6FE8B6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7CD7CAEE-9C1A-4520-8F85-FD9BFB0A57D9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*", matchCriteriaId: "BF513598-C3FA-4555-8133-A7276DDAFAC8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC", versionEndExcluding: "1.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", matchCriteriaId: "55058209-8AE5-42AF-80D4-5A7A44307266", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E", versionEndExcluding: "2.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "ECC84D6F-F5E0-47CF-B11E-1C43F866D972", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0C9D0595-53CD-48C0-82E3-DB0B2EC17721", versionEndExcluding: "1.0.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", matchCriteriaId: "34C17B00-34B5-4A15-9333-252BE2975F37", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EE0B998-E408-408F-8F78-5E90F74E9C9B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", matchCriteriaId: "0259EAE9-0CA0-49A5-A573-8339604A181B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", matchCriteriaId: "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "55BE63B0-F44E-4FCD-B00C-77595BACC62E", versionEndExcluding: "4.0.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", matchCriteriaId: "49DA8715-D671-4D8F-A870-E61960A5AFA4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D054139B-BE36-4B34-88AE-BC487DCB1DCB", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", matchCriteriaId: "3F0CE2EC-9A73-4576-A389-A19893D47B0F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", matchCriteriaId: "A1EC40E7-F004-446C-B5C9-0AB9911105E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3237684A-3BEA-462F-A91D-ABC94C90D15A", versionEndExcluding: "4.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", matchCriteriaId: "691CA334-4394-4ED6-B417-F67FC92228AE", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "32BD232D-A6BB-4D7B-BD00-1085D08D8A77", versionEndExcluding: "4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*", matchCriteriaId: "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0FE40195-DE5A-4B9C-9455-FAF92FF090D0", versionEndExcluding: "4.1.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*", matchCriteriaId: "9B339839-3D74-4E13-9EB6-24CA46F991A5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", matchCriteriaId: "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E9329BF4-D00A-4138-AA4C-93022002C0B9", versionEndExcluding: "4.4.0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*", matchCriteriaId: "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "E62802E3-AFA3-4023-9671-95C220397956", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8C46E084-9732-4920-86C2-3A91830CBCE3", versionEndExcluding: "4.2.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*", matchCriteriaId: "18C8B2FB-87C3-4DBB-9960-53FA545F26CB", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5", versionEndExcluding: "2.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*", matchCriteriaId: "598EEFC9-5240-4011-9017-A9557585AA19", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9461CADE-1624-4D1B-8CF2-CF65F75071C0", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", matchCriteriaId: "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2570E321-C28E-46FA-8693-1230B3B5FD1B", versionEndExcluding: "6.0.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*", matchCriteriaId: "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "582B49BD-4565-4D19-BBE6-A193BDFCE8B0", versionEndExcluding: "4.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", matchCriteriaId: "EC545350-FD53-4B2E-886F-E20F12260C9B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9D24953B-B3DF-4150-810C-64A94A55E829", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", matchCriteriaId: "30DDEA9B-E1BF-4572-8E12-D13C54603E77", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", versionEndExcluding: "2010", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", matchCriteriaId: "EA59D713-F342-4CDA-BDC8-108352D385DA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", matchCriteriaId: "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317", versionEndExcluding: "1.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*", matchCriteriaId: "8582A3E8-C05E-4D0B-851D-8C3181ED61CC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F84A65E6-4672-4B62-826E-6FAAE0B4A89D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3D42184E-8998-4C40-9612-5C9DE193CC06", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "98FDB53A-8F5D-46AA-9366-F6480B12D744", versionEndExcluding: "2.0.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "352651A0-F7CE-4689-8597-15F3764707A9", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FD2943F3-C46C-462E-9062-EE7B3E56CF72", versionEndExcluding: "1.4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*", matchCriteriaId: "975EFBBB-33E1-4D04-9E06-93553D45539C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", matchCriteriaId: "A1A43D34-ECA3-4330-B85F-02BDD1D22149", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5D7A7140-62A2-434F-AB79-1D47C918F1FE", versionEndExcluding: "1.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*", matchCriteriaId: "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", matchCriteriaId: "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "775C90BB-C026-435C-889A-517EF85656C5", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "CAA92AC6-7DA0-418D-A13F-69268DFD7966", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", matchCriteriaId: "D61D3E9C-1346-4354-BCD9-B02F67500C41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21ED7835-5D9B-4AF0-8E71-A4E7377FAD9F", versionEndExcluding: "4.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "64E77B7F-3E48-4C2C-9E2E-4AAEA6BCA71A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", matchCriteriaId: "373DBE44-AC28-4D04-93BB-35CD8C60E899", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AC731378-CB83-4C15-BC6A-5A86DF9B62F1", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "51A78A0B-5D75-418A-98AC-6EBF50D89A8A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", matchCriteriaId: "2296CA65-0E89-4BCB-8003-E7212BF1F585", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "35B36BC1-EE75-48D5-B511-C79891DA0F86", versionEndExcluding: "4.4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*", matchCriteriaId: "8C21EF20-693C-425F-A370-E84722856212", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "A4D7197E-C921-42CA-BE43-C96A4223F443", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "77A0BE57-1A9A-4564-9C53-CF47DEEF7991", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "376556D0-1AE2-4F80-B3CE-C0251E35C326", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", matchCriteriaId: "E5A824BD-935F-4E53-8313-C5544B0489C7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "772FF972-2193-4639-B454-F92762E49C39", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", matchCriteriaId: "0D48682C-A39D-4A09-B904-50FA64A9D2A5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8EE54303-4FDA-42C7-B33B-BA884CD31339", versionEndExcluding: "1.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "D870F289-F2BC-4105-A8F0-30E47CDE9FEF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "92A7198A-D6C5-4FBF-8860-5C8EA864718B", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*", matchCriteriaId: "879CF09E-4735-4A73-8E7B-215F2701F7E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "AEB948AA-7BD7-4A0F-B86E-38ECD722C086", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", matchCriteriaId: "7D97047C-9772-4AEB-B993-131EBBAE33BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "28E3AB24-86B4-485D-8D3A-131E5C7F0108", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "40AC387B-B799-4A34-8C9E-73D05B86801D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", matchCriteriaId: "765286DF-07EC-4C7A-AB8C-09559CD977EA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "CE53BC8E-CDA7-476A-87CA-532F365C79A7", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "A1150AED-CDBE-492C-95FF-3E02B3B447F1", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "1AAE6A83-737B-47A9-86BB-652C7F6A8013", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "42E8D21B-9CF4-4C2E-B33C-212BA29C7124", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "55E03180-BE77-4A22-A6C1-FE90B9760570", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "02610368-4B97-4B3F-8592-64CF8F65D8AD", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BE5003DA-5488-47C1-B442-9137E849FDD5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8BF91884-7532-4E15-A754-EBC430FD0E9D", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "921D7568-9FE9-4491-B099-A922984351DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", matchCriteriaId: "64D5B21D-0DC1-479B-810B-21E78F34A80A", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45B42950-8BD9-4933-9615-27FCC67C03A1", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "86ADBE36-CC1F-4F3C-81CA-ABA0F40AC212", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", matchCriteriaId: "7D97047C-9772-4AEB-B993-131EBBAE33BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6377EA6B-8EE3-4208-8FB0-175684A77B3F", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "D5AE6E9A-02B9-4A69-ACC4-EFBE1767E51E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", matchCriteriaId: "765286DF-07EC-4C7A-AB8C-09559CD977EA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D87643C3-6525-4CBD-BC0C-6B4DC30C8642", versionEndExcluding: "1.1.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", matchCriteriaId: "AE6AB995-D67B-43E5-B8FF-97C38D20CB10", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5C936A7A-1AF9-44E4-9CEC-0694A424616B", versionEndExcluding: "1.1.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", matchCriteriaId: "8DA1E7C4-6352-41A4-8A94-C24DDB456572", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.", }, { lang: "es", value: "Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condición de denegación de servicio de ese producto. Se requiere la interacción humana para recuperar el sistema. Las interfaces PROFIBUS no están afectadas. Esta vulnerabilidad sólo afecta a los SIMATIC HMI Multi Panels y HMI Mobile Panels, y a los dispositivos S7-300/S7-400", }, ], id: "CVE-2017-2681", lastModified: "2024-11-21T03:23:57.917", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "ADJACENT_NETWORK", authentication: "NONE", availabilityImpact: "COMPLETE", baseScore: 6.1, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:A/AC:L/Au:N/C:N/I:N/A:C", version: "2.0", }, exploitabilityScore: 6.5, impactScore: 6.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "ADJACENT_NETWORK", availabilityImpact: "HIGH", baseScore: 6.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 2.8, impactScore: 3.6, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "ADJACENT_NETWORK", availabilityImpact: "HIGH", baseScore: 6.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 2.8, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], cvssMetricV40: [ { cvssData: { Automatable: "NOT_DEFINED", Recovery: "NOT_DEFINED", Safety: "NOT_DEFINED", attackComplexity: "LOW", attackRequirements: "NONE", attackVector: "ADJACENT", availabilityRequirement: "NOT_DEFINED", baseScore: 7.1, baseSeverity: "HIGH", confidentialityRequirement: "NOT_DEFINED", exploitMaturity: "NOT_DEFINED", integrityRequirement: "NOT_DEFINED", modifiedAttackComplexity: "NOT_DEFINED", modifiedAttackRequirements: "NOT_DEFINED", modifiedAttackVector: "NOT_DEFINED", modifiedPrivilegesRequired: "NOT_DEFINED", modifiedSubAvailabilityImpact: "NOT_DEFINED", modifiedSubConfidentialityImpact: "NOT_DEFINED", modifiedSubIntegrityImpact: "NOT_DEFINED", modifiedUserInteraction: "NOT_DEFINED", modifiedVulnAvailabilityImpact: "NOT_DEFINED", modifiedVulnConfidentialityImpact: "NOT_DEFINED", modifiedVulnIntegrityImpact: "NOT_DEFINED", privilegesRequired: "NONE", providerUrgency: "NOT_DEFINED", subAvailabilityImpact: "NONE", subConfidentialityImpact: "NONE", subIntegrityImpact: "NONE", userInteraction: "NONE", valueDensity: "NOT_DEFINED", vectorString: "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", version: "4.0", vulnAvailabilityImpact: "HIGH", vulnConfidentialityImpact: "NONE", vulnIntegrityImpact: "NONE", vulnerabilityResponseEffort: "NOT_DEFINED", }, source: "productcert@siemens.com", type: "Secondary", }, ], }, published: "2017-05-11T10:29:00.180", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/98369", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securitytracker.com/id/1038463", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { source: "productcert@siemens.com", tags: [ "Broken Link", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/98369", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securitytracker.com/id/1038463", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Broken Link", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-400", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-400", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:13
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.
An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-625862.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-693975.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-625862.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-693975.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | 6gk7243-8rx30-0xe0_firmware | - | |
siemens | 6gk7243-8rx30-0xe0 | - | |
siemens | 6gk7543-1ax00-0xe0_firmware | - | |
siemens | 6gk7543-1ax00-0xe0 | - | |
siemens | 6ag1543-1ax00-2xe0_firmware | - | |
siemens | 6ag1543-1ax00-2xe0 | - | |
siemens | simatic_cp_1242-7_v2_firmware | - | |
siemens | simatic_cp_1242-7_v2 | - | |
siemens | simatic_cp_1243-1_firmware | - | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | - | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cp_1243-1_iec_firmware | - | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-7_lte_firmware | - | |
siemens | simatic_cp_1243-7_lte | * | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 5.2 | |
siemens | sinamics_s210_firmware | 6.1 | |
siemens | sinamics_s210_firmware | 6.1 | |
siemens | sinamics_s210 | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:6gk7243-8rx30-0xe0_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "BBBD0600-DB41-4DE8-97FC-2D180DA1406F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:6gk7243-8rx30-0xe0:-:*:*:*:*:*:*:*", matchCriteriaId: "A50A52E7-D8FE-4071-99B3-3652B0892D07", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:6gk7543-1ax00-0xe0_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "EF7C15EC-3C83-434B-A313-9035302EEF87", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:6gk7543-1ax00-0xe0:-:*:*:*:*:*:*:*", matchCriteriaId: "E42E7B79-A3D2-4AAC-80E2-7E5C19A72CC5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:6ag1543-1ax00-2xe0_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "9373F60E-03D0-4EB2-9774-6479A8F342C7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:6ag1543-1ax00-2xe0:-:*:*:*:*:*:*:*", matchCriteriaId: "F9063778-2B5F-4A32-83C8-6CEB9EE8F9C0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "66A2C7F2-F787-4770-8F56-E2AFF1AFD780", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "29D4C72C-4E84-4563-9D66-5C641AB996BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "373B769D-0E60-4362-BAE1-90BA6E0B211C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "1158D559-2A46-4BE4-B16E-C2789AD3C60E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "1C3E8B50-07E9-4697-B42D-86B9BE942553", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "7FC29937-7A70-4A9F-89F8-8D17E285C225", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte:*:*:*:*:*:*:*:*", matchCriteriaId: "BAFC3319-F07C-4784-9873-3E1907FE3080", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*", matchCriteriaId: "BEBF14B3-65A0-41E9-B99C-D88548F307CD", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*", matchCriteriaId: "F151297C-3097-483F-98B5-0261BD547421", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1_hotfix8:*:*:*:*:*:*", matchCriteriaId: "4CEAB952-BBF0-4585-8F12-F25A192FAA1B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:-:*:*:*:*:*:*", matchCriteriaId: "7F4D3F85-4CA5-438E-955E-C039F7DE91B1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix2:*:*:*:*:*:*", matchCriteriaId: "59608DD3-87C3-4ED1-B0C2-AFD31A7A70A3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix5:*:*:*:*:*:*", matchCriteriaId: "EA3D3D7E-CB48-4B8D-8101-CB0DADEEC0B1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix6:*:*:*:*:*:*", matchCriteriaId: "6F8FC52F-3648-410B-8BCB-76129ABC0D4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix7:*:*:*:*:*:*", matchCriteriaId: "59BDCF31-2D94-4D7D-9EC8-60726B10DFC7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3:*:*:*:*:*:*", matchCriteriaId: "D62C3EEA-000C-41CD-8264-4A4B6AE1BAD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix3:*:*:*:*:*:*", matchCriteriaId: "EF00EE34-1A68-40F0-A9FC-FBBF268C6400", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix5:*:*:*:*:*:*", matchCriteriaId: "C6BB896A-8C42-416E-AE03-D5A0E122BA79", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*", matchCriteriaId: "B18F1100-8157-4E99-AB22-BF51EB1663B3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*", matchCriteriaId: "AA9B1D54-E3A0-4EFF-8EB2-A52B8E1F117F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:-:*:*:*:*:*:*", matchCriteriaId: "E509394F-9987-41D2-A866-68479FF39DCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:hotfix1:*:*:*:*:*:*", matchCriteriaId: "2DEB162B-6579-4280-9BCC-403C1B351002", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*", matchCriteriaId: "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en:\nSIMATIC CP 1242-7 V2 (incluidas las variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-1 (incluidas las variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-1 DNP3 (incluidas las variantes SIPLUS) ) (todas las versiones), \nSIMATIC CP 1243-1 IEC (incl. variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-7 LTE (todas las versiones), \nSIMATIC CP 1243-8 IRC (todas las versiones), \nSIMATIC CP 1543-1 (Todas las versiones), \nSINAMICS S210 (6SL5...) (Todas las versiones >= V6.1 < V6.1 HF2), \nSIPLUS NET CP 1543-1 (Todas las versiones). \nLa implementación del servidor web de los productos afectados no libera correctamente la memoria asignada una vez utilizada. Un atacante con acceso a la red podría utilizar esta vulnerabilidad para provocar una condición de denegación de servicio en el servidor web del producto afectado.", }, ], id: "CVE-2023-38380", lastModified: "2024-11-21T08:13:26.780", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Primary", }, ], cvssMetricV40: [ { cvssData: { Automatable: "NOT_DEFINED", Recovery: "NOT_DEFINED", Safety: "NOT_DEFINED", attackComplexity: "LOW", attackRequirements: "NONE", attackVector: "NETWORK", availabilityRequirement: "NOT_DEFINED", baseScore: 8.7, baseSeverity: "HIGH", confidentialityRequirement: "NOT_DEFINED", exploitMaturity: "NOT_DEFINED", integrityRequirement: "NOT_DEFINED", modifiedAttackComplexity: "NOT_DEFINED", modifiedAttackRequirements: "NOT_DEFINED", modifiedAttackVector: "NOT_DEFINED", modifiedPrivilegesRequired: "NOT_DEFINED", modifiedSubAvailabilityImpact: "NOT_DEFINED", modifiedSubConfidentialityImpact: "NOT_DEFINED", modifiedSubIntegrityImpact: "NOT_DEFINED", modifiedUserInteraction: "NOT_DEFINED", modifiedVulnAvailabilityImpact: "NOT_DEFINED", modifiedVulnConfidentialityImpact: "NOT_DEFINED", modifiedVulnIntegrityImpact: "NOT_DEFINED", privilegesRequired: "NONE", providerUrgency: "NOT_DEFINED", subAvailabilityImpact: "NONE", subConfidentialityImpact: "NONE", subIntegrityImpact: "NONE", userInteraction: "NONE", valueDensity: "NOT_DEFINED", vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", version: "4.0", vulnAvailabilityImpact: "HIGH", vulnConfidentialityImpact: "NONE", vulnIntegrityImpact: "NONE", vulnerabilityResponseEffort: "NOT_DEFINED", }, source: "productcert@siemens.com", type: "Primary", }, ], }, published: "2023-12-12T12:15:11.477", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-625862.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-693975.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-625862.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-693975.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-401", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-401", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_1242-7_v2_firmware | * | |
siemens | simatic_cp_1242-7_v2 | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-7_lte_eu_firmware | * | |
siemens | simatic_cp_1243-7_lte_eu | - | |
siemens | simatic_cp_1243-7_lte_us_firmware | * | |
siemens | simatic_cp_1243-7_lte_us | - | |
siemens | simatic_cp_1243-8_irc_firmware | * | |
siemens | simatic_cp_1243-8_irc | - | |
siemens | simatic_cp_1542sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_443-1_firmware | * | |
siemens | simatic_cp_443-1 | - | |
siemens | simatic_cp_443-1_advanced_firmware | * | |
siemens | simatic_cp_443-1_advanced | - | |
siemens | simatic_ipc_diagbase_firmware | * | |
siemens | simatic_ipc_diagbase | - | |
siemens | simatic_ipc_diagmonitor_firmware | * | |
siemens | simatic_ipc_diagmonitor | - | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail | - | |
siemens | siplus_net_cp_1242-7_v2_firmware | * | |
siemens | siplus_net_cp_1242-7_v2 | - | |
siemens | siplus_net_cp_443-1_firmware | * | |
siemens | siplus_net_cp_443-1 | - | |
siemens | siplus_net_cp_443-1_advanced_firmware | * | |
siemens | siplus_net_cp_443-1_advanced | - | |
siemens | siplus_s7-1200_cp_1243-1_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1 | - | |
siemens | siplus_s7-1200_cp_1243-1_rail_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1_rail | - | |
siemens | siplus_tim_1531_irc_firmware | * | |
siemens | siplus_tim_1531_irc | - | |
siemens | tim_1531_irc_firmware | * | |
siemens | tim_1531_irc | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "840C5C25-1E34-42FA-8221-7232622C204F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "29D4C72C-4E84-4563-9D66-5C641AB996BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FE3D7928-8E1A-400E-B790-58D6F5938E3C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BE5003DA-5488-47C1-B442-9137E849FDD5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "93D43BC6-EDE3-4EE1-9410-4717EB641AD0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*", matchCriteriaId: "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "786F3FFD-87E4-45B9-A33C-BAE58379FF39", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*", matchCriteriaId: "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "12A45F37-1E7D-4748-ADAC-EC4C454B693A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C1F51B86-57EE-4DB6-B038-06726BC93D2D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8648EF79-043D-48DE-B9F8-BF762862EE99", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C8B5C37-200C-4531-8876-3E05F3DE3EC8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "843A8686-5172-4782-BB97-B5D3C6FB27A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BCDA714C-5851-4E35-806F-E0C651A1E87A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F58423D0-954E-426E-9F8F-3DD95FBDF50C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "530FD06D-E020-4EB3-87DD-F7B2FEE58008", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*", matchCriteriaId: "8784BA58-12BF-4F1C-94D6-2D15933703C8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "91371CD0-EBDF-43C5-A262-A46E1C343716", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*", matchCriteriaId: "A5E06833-4C26-40AC-B6CF-F7D1322462D6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AE009635-7EC7-4A2F-B1FA-DD75213A25CA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9054A7B6-9569-4D65-9695-A0FFA4F56C74", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*", matchCriteriaId: "A60FC550-A518-46BF-9124-E21DD654981C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4F488C27-C8B9-4238-8409-AB7ACA3BC849", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7FE26E32-47C0-4976-A23A-07C1AE318C35", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "116E84DA-31F7-4AAC-A1AE-491C4C98BD49", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45B95689-C355-4CF1-AE7A-0860E4CEA11A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "21F04D79-5815-4D36-8AA5-4866751D0DDB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "2498071A-6540-4147-8D01-3B81A5CE9A57", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F9E746CF-4009-4A14-8916-A9E0276CAF8B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "4A294530-727C-4535-8B02-668DF74587D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2C616E50-1F96-4A87-8470-1BA8732FCB77", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "074FDC9C-CB36-4C67-82C8-1B930FF1269F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "C1D94BEB-BBFB-4258-9835-87DBBB999239", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.", }, ], id: "CVE-2022-43767", lastModified: "2024-11-21T07:27:11.520", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Primary", }, ], }, published: "2023-04-11T10:15:17.540", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-833", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "NVD-CWE-noinfo", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-139628.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-566905.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_1242-7_v2_firmware | * | |
siemens | simatic_cp_1242-7_v2 | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-7_lte_eu_firmware | * | |
siemens | simatic_cp_1243-7_lte_eu | - | |
siemens | simatic_cp_1243-7_lte_us_firmware | * | |
siemens | simatic_cp_1243-7_lte_us | - | |
siemens | simatic_cp_1243-8_irc_firmware | * | |
siemens | simatic_cp_1243-8_irc | - | |
siemens | simatic_cp_1542sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_443-1_firmware | * | |
siemens | simatic_cp_443-1 | - | |
siemens | simatic_cp_443-1_advanced_firmware | * | |
siemens | simatic_cp_443-1_advanced | - | |
siemens | simatic_ipc_diagbase_firmware | * | |
siemens | simatic_ipc_diagbase | - | |
siemens | simatic_ipc_diagmonitor_firmware | * | |
siemens | simatic_ipc_diagmonitor | - | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1542sp-1_irc_tx_rail | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec | - | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware | * | |
siemens | siplus_et_200sp_cp_1543sp-1_isec_tx_rail | - | |
siemens | siplus_net_cp_1242-7_v2_firmware | * | |
siemens | siplus_net_cp_1242-7_v2 | - | |
siemens | siplus_net_cp_443-1_firmware | * | |
siemens | siplus_net_cp_443-1 | - | |
siemens | siplus_net_cp_443-1_advanced_firmware | * | |
siemens | siplus_net_cp_443-1_advanced | - | |
siemens | siplus_s7-1200_cp_1243-1_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1 | - | |
siemens | siplus_s7-1200_cp_1243-1_rail_firmware | * | |
siemens | siplus_s7-1200_cp_1243-1_rail | - | |
siemens | siplus_tim_1531_irc_firmware | * | |
siemens | siplus_tim_1531_irc | - | |
siemens | tim_1531_irc_firmware | * | |
siemens | tim_1531_irc | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "840C5C25-1E34-42FA-8221-7232622C204F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "29D4C72C-4E84-4563-9D66-5C641AB996BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FE3D7928-8E1A-400E-B790-58D6F5938E3C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BE5003DA-5488-47C1-B442-9137E849FDD5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "93D43BC6-EDE3-4EE1-9410-4717EB641AD0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*", matchCriteriaId: "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "786F3FFD-87E4-45B9-A33C-BAE58379FF39", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*", matchCriteriaId: "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "12A45F37-1E7D-4748-ADAC-EC4C454B693A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C1F51B86-57EE-4DB6-B038-06726BC93D2D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8648EF79-043D-48DE-B9F8-BF762862EE99", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C8B5C37-200C-4531-8876-3E05F3DE3EC8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "843A8686-5172-4782-BB97-B5D3C6FB27A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BCDA714C-5851-4E35-806F-E0C651A1E87A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F58423D0-954E-426E-9F8F-3DD95FBDF50C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "530FD06D-E020-4EB3-87DD-F7B2FEE58008", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*", matchCriteriaId: "8784BA58-12BF-4F1C-94D6-2D15933703C8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "91371CD0-EBDF-43C5-A262-A46E1C343716", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*", matchCriteriaId: "A5E06833-4C26-40AC-B6CF-F7D1322462D6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AE009635-7EC7-4A2F-B1FA-DD75213A25CA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9054A7B6-9569-4D65-9695-A0FFA4F56C74", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*", matchCriteriaId: "A60FC550-A518-46BF-9124-E21DD654981C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4F488C27-C8B9-4238-8409-AB7ACA3BC849", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7FE26E32-47C0-4976-A23A-07C1AE318C35", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*", matchCriteriaId: "116E84DA-31F7-4AAC-A1AE-491C4C98BD49", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45B95689-C355-4CF1-AE7A-0860E4CEA11A", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "21F04D79-5815-4D36-8AA5-4866751D0DDB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62", versionEndExcluding: "3.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "2498071A-6540-4147-8D01-3B81A5CE9A57", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "F9E746CF-4009-4A14-8916-A9E0276CAF8B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*", matchCriteriaId: "4A294530-727C-4535-8B02-668DF74587D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2C616E50-1F96-4A87-8470-1BA8732FCB77", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "074FDC9C-CB36-4C67-82C8-1B930FF1269F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21", versionEndExcluding: "2.3.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "C1D94BEB-BBFB-4258-9835-87DBBB999239", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.", }, ], id: "CVE-2022-43716", lastModified: "2024-11-21T07:27:07.160", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Primary", }, { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Secondary", }, ], }, published: "2023-04-11T10:15:17.467", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-139628.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-566905.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-416", }, ], source: "productcert@siemens.com", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2017-05-11 01:29
Modified
2024-11-21 03:23
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | Vendor Advisory | |
productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | Third Party Advisory, US Government Resource | |
productcert@siemens.com | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_343-1_std_firmware | * | |
siemens | simatic_cp_343-1_std | - | |
siemens | simatic_cp_343-1_lean_firmware | * | |
siemens | simatic_cp_343-1_lean | - | |
siemens | simatic_cp_343-1_adv_firmware | * | |
siemens | simatic_cp_343-1_adv | - | |
siemens | simatic_cp_443-1_std_firmware | * | |
siemens | simatic_cp_443-1_std | - | |
siemens | simatic_cp_443-1_adv_firmware | * | |
siemens | simatic_cp_443-1_adv | - | |
siemens | simatic_cp_443-1_opc-ua_firmware | * | |
siemens | simatic_cp_443-1_opc-ua | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cm_1542-1_firmware | * | |
siemens | simatic_cm_1542-1 | - | |
siemens | simatic_cp_1542sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_1543-1_firmware | * | |
siemens | simatic_cp_1543-1 | - | |
siemens | simatic_rf650r_firmware | * | |
siemens | simatic_rf650r | - | |
siemens | simatic_rf680r_firmware | * | |
siemens | simatic_rf680r | - | |
siemens | simatic_rf685r_firmware | * | |
siemens | simatic_rf685r | - | |
siemens | simatic_cp_1616_firmware | * | |
siemens | simatic_cp_1616 | - | |
siemens | simatic_cp_1604_firmware | * | |
siemens | simatic_cp_1604 | - | |
siemens | simatic_dk-1616_pn_io_firmware | * | |
siemens | simatic_dk-1616_pn_io | - | |
siemens | scalance_x200_firmware | * | |
siemens | scalance_x200 | - | |
siemens | scalance_x200_irt_firmware | * | |
siemens | scalance_x200_irt | - | |
siemens | scalance_x300_firmware | * | |
siemens | scalance_x300 | - | |
siemens | scalance_x408_firmware | * | |
siemens | scalance_x408 | - | |
siemens | scalance_x414_firmware | * | |
siemens | scalance_x414 | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | softnet_profinet_io_firmware | * | |
siemens | softnet_profinet_io_firmware | 14 | |
siemens | softnet_profinet_io | - | |
siemens | ie\/pb-link_firmware | * | |
siemens | ie\/pb-link | - | |
siemens | ie\/as-i_link_pn_io_firmware | * | |
siemens | ie\/as-i_link_pn_io | - | |
siemens | simatic_teleservice_adapter_ie_standard_firmware | * | |
siemens | simatic_teleservice_adapter_ie_standard | - | |
siemens | simatic_teleservice_adapter_ie_basic_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic | - | |
siemens | simatic_teleservice_adapter_ie_advanced_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced_modem | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | ups1600_profinet_firmware | * | |
siemens | ups1600_profinet | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_firmware | * | |
siemens | simatic_et_200mp | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_firmware | * | |
siemens | simatic_et_200sp | - | |
siemens | pn\/pn_coupler_firmware | * | |
siemens | pn\/pn_coupler | - | |
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200p_pn_io_firmware | * | |
siemens | ek-ertec_200p_pn_io_firmware | 4.4.0 | |
siemens | ek-ertec_200p_pn_io | - | |
siemens | ek-ertec_200_pn_io_firmware | * | |
siemens | ek-ertec_200_pn_io_firmware | 4.2.1 | |
siemens | ek-ertec_200_pn_io | - | |
siemens | simatic_s7-200_smart_firmware | * | |
siemens | simatic_s7-200_smart | - | |
siemens | simatic_s7-300_firmware | - | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_firmware | * | |
siemens | simatic_s7-400 | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_s7-1500_software_controller_firmware | * | |
siemens | simatic_s7-1500_software_controller | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | sirius_act_3su1_firmware | * | |
siemens | sirius_act_3su1 | - | |
siemens | sirius_soft_starter_3rw44_pn_firmware | * | |
siemens | sirius_soft_starter_3rw44_pn | - | |
siemens | sirius_motor_starter_m200d_profinet_firmware | * | |
siemens | sirius_motor_starter_m200d_profinet | - | |
siemens | simocode_pro_v_profinet_firmware | * | |
siemens | simocode_pro_v_profinet | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp_firmware | 1.2 | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn_firmware | * | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn_firmware | 4.7 | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 4.7 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 4.7 | |
siemens | sinamics_g150 | - | |
siemens | sinamics__s110_pn_firmware | * | |
siemens | sinamics__s110_pn_firmware | 4.4 | |
siemens | _s110_pn | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 4.7 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 4.7 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_v90_pn_firmware | * | |
siemens | sinamics_v90_pn | - | |
siemens | simotion_firmware | * | |
siemens | simotion_firmware | 4.5 | |
siemens | simotion | - | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.5 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.5 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_hmi_comfort_panels | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_multi_panels | * | |
siemens | simatic_hmi_multi_panels | - | |
siemens | simatic_hmi_mobile_panels | * | |
siemens | simatic_hmi_mobile_panels | - | |
siemens | simatic_cp_1243-1_irc_firmware | * | |
siemens | simatic_cp_1243-1_irc | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_dk-1604_pn_io_firmware | * | |
siemens | simatic_dk-1604_pn_io | - | |
siemens | simatic_tdc_cpu555_firmware | * | |
siemens | simatic_tdc_cpu555 | - | |
siemens | simatic_tdc_cp51m1_firmware | * | |
siemens | simatic_tdc_cp51m1 | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150_firmware | 4.7 | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.7 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.8 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120_firmware | 4.8 | |
siemens | sinamics_sm120 | - | |
siemens | extension_unit_12_profinet_firmware | * | |
siemens | extension_unit_12_profinet | - | |
siemens | extension_unit_15_profinet_firmware | * | |
siemens | extension_unit_15_profinet | - | |
siemens | extension_unit_19_profinet_firmware | * | |
siemens | extension_unit_19_profinet | - | |
siemens | extension_unit_22_profinet_firmware | * | |
siemens | extension_unit_22_profinet | - | |
siemens | simatic_cp_1242-7_gprs_firmware | * | |
siemens | simatic_cp_1242-7_gprs | - | |
siemens | simatic_cp_1243-7_lte\/us_firmware | * | |
siemens | simatic_cp_1243-7_lte\/us | - | |
siemens | simatic_cp_1243-8_firmware | * | |
siemens | simatic_cp_1243-8 | - | |
siemens | simatic_cp_1626_firmware | * | |
siemens | simatic_cp_1626 | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFF143FA-311E-4081-805F-BBDB72003556", versionEndExcluding: "3.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*", matchCriteriaId: "9C351559-6D8D-4EA8-87D6-83003844BD97", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A", versionEndExcluding: "3.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*", matchCriteriaId: "EE2A18E2-F88F-4DC1-81E9-AC836C85A248", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7E0622A2-C918-4062-938A-8736469F8286", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*", matchCriteriaId: "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481", versionEndExcluding: "3.2.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*", matchCriteriaId: "BB8C873A-25EB-4787-9F25-DC5852337093", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "58E4035F-02AB-4B6D-A9AF-556DBE021C30", versionEndExcluding: "3.2.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*", matchCriteriaId: "75013961-5B00-42E9-9061-CF2E9A4FC090", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*", matchCriteriaId: "977E97C8-959F-4146-8BFD-0FCF014B1534", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "EBE1A019-4BC4-4352-BA16-05629A20F89F", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", matchCriteriaId: "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*", matchCriteriaId: "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "18B597C8-0401-458F-8DF9-062B5E833115", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CA3E3782-7F36-4BC3-8D00-E1961E3105E3", versionEndExcluding: "1.0.15", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", matchCriteriaId: "843A8686-5172-4782-BB97-B5D3C6FB27A3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "807D97E1-7680-4B8F-85AD-F56F039669D1", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*", matchCriteriaId: "3FDE92FB-38C7-46E8-9208-BBD7872219D5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "37B4E3A9-FE27-4A31-A213-92B461A5C846", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*", matchCriteriaId: "C82C2C69-D983-4317-968B-D1855DF8AE43", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "177A6E55-8D64-4CB8-B366-AE272E715932", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*", matchCriteriaId: "450DE127-DFED-4799-B8EA-0F95028E4BC3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "72D14DB5-6132-4442-8AB2-3ECE89B1D47C", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*", matchCriteriaId: "63F70060-0090-4BD7-8BF6-769989879ACD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", matchCriteriaId: "CA074FBE-1C3E-4441-8C51-52B555B85D9F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0424AECD-68D5-45F1-9F55-B72CB4DFE39C", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", matchCriteriaId: "6304FA24-F194-4EE2-95F5-35D086F82C01", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "39663B8F-F349-49B3-A0CB-004F11D01E34", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "C8F515DF-36AC-49C1-B013-E87529775AB3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45008AE8-8386-4CBA-8C38-10C1A60150C2", versionEndExcluding: "5.2.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*", matchCriteriaId: "A59C91EA-5D1B-4970-8C36-BD76BA420B12", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7F61995A-2018-4DAA-9529-BADC145B267F", versionEndExcluding: "5.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*", matchCriteriaId: "CAF3DA7A-6B80-4F20-835F-BF071197D1B0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3", versionEndExcluding: "4.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*", matchCriteriaId: "E3F6299B-D7E3-4750-B016-7DCBC83C2287", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B8A4CF89-9DDA-4974-A886-CC0A912017F7", versionEndExcluding: "4.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*", matchCriteriaId: "47F713E4-4B75-476E-BC21-92CA10198AE9", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2CA7C987-779A-4B64-BFAC-73D54618AF04", versionEndExcluding: "3.10.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*", matchCriteriaId: "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", matchCriteriaId: "9FC408A8-903F-43A2-9D05-65AD4482FDBB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B9AF696-211F-4CAD-8A0E-402487E8DC50", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", matchCriteriaId: "080E722F-FCD4-4967-86EE-151ADC5702E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D8763BB9-5DDA-4817-BDA6-63983CD4BC67", versionEndExcluding: "6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", matchCriteriaId: "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5", versionEndExcluding: "4.03", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", matchCriteriaId: "DFB9921A-5204-40A3-88AB-B7755F5C6875", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE", versionEndExcluding: "4.03", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", matchCriteriaId: "E917CBBB-EF41-4113-B0CA-EB91889235E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9831567D-6528-4ACA-99F9-1EC42CB4A90D", versionEndExcluding: "14", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*", matchCriteriaId: "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*", matchCriteriaId: "E348069A-B809-4DF6-81E9-DC52C6E2C268", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8ED91175-0AF3-424A-8C49-43587BB95EAB", versionEndExcluding: "3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*", matchCriteriaId: "8D43C16C-0719-4648-903F-6CC0FFF1835A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7E909C1E-9329-4459-ACE3-AD906CD4A968", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "317863B6-0B71-4D03-83FE-FC59EBB5307C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5C887573-8BE8-42CF-B35A-22F9311AC627", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*", matchCriteriaId: "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "80D166A8-1EEC-42F4-8EAB-1747247A7A05", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*", matchCriteriaId: "FFA520B6-5177-43E4-87C0-C215F79FE9B4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*", matchCriteriaId: "BF513598-C3FA-4555-8133-A7276DDAFAC8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC", versionEndExcluding: "1.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", matchCriteriaId: "55058209-8AE5-42AF-80D4-5A7A44307266", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E", versionEndExcluding: "2.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "ECC84D6F-F5E0-47CF-B11E-1C43F866D972", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0C9D0595-53CD-48C0-82E3-DB0B2EC17721", versionEndExcluding: "1.0.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", matchCriteriaId: "34C17B00-34B5-4A15-9333-252BE2975F37", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EE0B998-E408-408F-8F78-5E90F74E9C9B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", matchCriteriaId: "0259EAE9-0CA0-49A5-A573-8339604A181B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", matchCriteriaId: "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "55BE63B0-F44E-4FCD-B00C-77595BACC62E", versionEndExcluding: "4.0.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", matchCriteriaId: "49DA8715-D671-4D8F-A870-E61960A5AFA4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D054139B-BE36-4B34-88AE-BC487DCB1DCB", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", matchCriteriaId: "3F0CE2EC-9A73-4576-A389-A19893D47B0F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", matchCriteriaId: "A1EC40E7-F004-446C-B5C9-0AB9911105E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E6BACBC9-7C60-4A41-B8C6-A5E46B568029", versionEndExcluding: "4.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", matchCriteriaId: "691CA334-4394-4ED6-B417-F67FC92228AE", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "32BD232D-A6BB-4D7B-BD00-1085D08D8A77", versionEndExcluding: "4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*", matchCriteriaId: "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0FE40195-DE5A-4B9C-9455-FAF92FF090D0", versionEndExcluding: "4.1.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*", matchCriteriaId: "9B339839-3D74-4E13-9EB6-24CA46F991A5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", matchCriteriaId: "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E9329BF4-D00A-4138-AA4C-93022002C0B9", versionEndExcluding: "4.4.0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*", matchCriteriaId: "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "E62802E3-AFA3-4023-9671-95C220397956", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8C46E084-9732-4920-86C2-3A91830CBCE3", versionEndExcluding: "4.2.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*", matchCriteriaId: "18C8B2FB-87C3-4DBB-9960-53FA545F26CB", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5", versionEndExcluding: "2.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*", matchCriteriaId: "598EEFC9-5240-4011-9017-A9557585AA19", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "4C096137-C1E3-4D19-87A9-BEB7A081DD1E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", matchCriteriaId: "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2570E321-C28E-46FA-8693-1230B3B5FD1B", versionEndExcluding: "6.0.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*", matchCriteriaId: "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "582B49BD-4565-4D19-BBE6-A193BDFCE8B0", versionEndExcluding: "4.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", matchCriteriaId: "EC545350-FD53-4B2E-886F-E20F12260C9B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9D24953B-B3DF-4150-810C-64A94A55E829", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", matchCriteriaId: "30DDEA9B-E1BF-4572-8E12-D13C54603E77", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E696D071-8601-40AA-BAF5-1452940E1D6E", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*", matchCriteriaId: "FE4D4D21-9868-4FA3-89A8-1EEC473383EF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", versionEndExcluding: "2010", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", matchCriteriaId: "EA59D713-F342-4CDA-BDC8-108352D385DA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", matchCriteriaId: "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317", versionEndExcluding: "1.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*", matchCriteriaId: "8582A3E8-C05E-4D0B-851D-8C3181ED61CC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F84A65E6-4672-4B62-826E-6FAAE0B4A89D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3D42184E-8998-4C40-9612-5C9DE193CC06", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "98FDB53A-8F5D-46AA-9366-F6480B12D744", versionEndExcluding: "2.0.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "352651A0-F7CE-4689-8597-15F3764707A9", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FD2943F3-C46C-462E-9062-EE7B3E56CF72", versionEndExcluding: "1.4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*", matchCriteriaId: "975EFBBB-33E1-4D04-9E06-93553D45539C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*", matchCriteriaId: "99A0D811-2751-420E-AD85-B6EC777C8CAE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", matchCriteriaId: "A1A43D34-ECA3-4330-B85F-02BDD1D22149", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5D7A7140-62A2-434F-AB79-1D47C918F1FE", versionEndExcluding: "1.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*", matchCriteriaId: "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", matchCriteriaId: "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "775C90BB-C026-435C-889A-517EF85656C5", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "CAA92AC6-7DA0-418D-A13F-69268DFD7966", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", matchCriteriaId: "D61D3E9C-1346-4354-BCD9-B02F67500C41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "413AA7BE-CFE1-49DB-965F-1BD50D61F82F", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "82B4BE4B-3AE5-4039-B18D-A5DE3F1DDEF8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*", matchCriteriaId: "0EE820D5-16B2-4565-9D83-AF018C08B5E5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", matchCriteriaId: "373DBE44-AC28-4D04-93BB-35CD8C60E899", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AC731378-CB83-4C15-BC6A-5A86DF9B62F1", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "51A78A0B-5D75-418A-98AC-6EBF50D89A8A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", matchCriteriaId: "2296CA65-0E89-4BCB-8003-E7212BF1F585", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7143613F-4627-4F62-8F1B-E64CCB20F3D1", versionEndExcluding: "4.4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*", matchCriteriaId: "B428560B-2CAC-4A63-B677-724D95E12023", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "23B97849-01A7-4A8F-84DD-D25CF84D010B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "77A0BE57-1A9A-4564-9C53-CF47DEEF7991", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "376556D0-1AE2-4F80-B3CE-C0251E35C326", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", matchCriteriaId: "E5A824BD-935F-4E53-8313-C5544B0489C7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "772FF972-2193-4639-B454-F92762E49C39", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", matchCriteriaId: "0D48682C-A39D-4A09-B904-50FA64A9D2A5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8EE54303-4FDA-42C7-B33B-BA884CD31339", versionEndExcluding: "1.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "D870F289-F2BC-4105-A8F0-30E47CDE9FEF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "92A7198A-D6C5-4FBF-8860-5C8EA864718B", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*", matchCriteriaId: "879CF09E-4735-4A73-8E7B-215F2701F7E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "AEB948AA-7BD7-4A0F-B86E-38ECD722C086", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", matchCriteriaId: "7D97047C-9772-4AEB-B993-131EBBAE33BA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "28E3AB24-86B4-485D-8D3A-131E5C7F0108", versionEndExcluding: "4.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*", matchCriteriaId: "40AC387B-B799-4A34-8C9E-73D05B86801D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", matchCriteriaId: "765286DF-07EC-4C7A-AB8C-09559CD977EA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "CE53BC8E-CDA7-476A-87CA-532F365C79A7", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "A1150AED-CDBE-492C-95FF-3E02B3B447F1", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "1AAE6A83-737B-47A9-86BB-652C7F6A8013", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*", matchCriteriaId: "42E8D21B-9CF4-4C2E-B33C-212BA29C7124", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "55E03180-BE77-4A22-A6C1-FE90B9760570", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "02610368-4B97-4B3F-8592-64CF8F65D8AD", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BE5003DA-5488-47C1-B442-9137E849FDD5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", matchCriteriaId: "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", matchCriteriaId: "2FFBFB96-1A35-4724-831B-68E3A9C32921", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "65EDC583-1BCE-4787-820F-39DBD280DADF", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*", matchCriteriaId: "568ED124-AEE8-4BDC-BB89-0F8F83BA7537", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D87643C3-6525-4CBD-BC0C-6B4DC30C8642", versionEndExcluding: "1.1.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", matchCriteriaId: "AE6AB995-D67B-43E5-B8FF-97C38D20CB10", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5C936A7A-1AF9-44E4-9CEC-0694A424616B", versionEndExcluding: "1.1.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", matchCriteriaId: "8DA1E7C4-6352-41A4-8A94-C24DDB456572", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D3F052D2-B537-4BF9-AF05-60107FDE0BEA", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "96C7E194-617D-4593-B544-10AEFF59CCA5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3653DA37-DB23-41E0-8CE8-838E384AA40A", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1BF93390-E65B-434E-9891-271DF7D11F47", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "55F6B737-7237-4D38-A0F0-9EFCE76DC9C4", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FD67D30A-8681-41AE-B248-7E50BA1B9FC8", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "31393A1B-4DBC-476D-875E-463B4B887E1B", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0206F9F2-27C7-4D2F-817B-13F8FA31E547", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E789146F-1FA4-42E4-B867-FD0F5A7316CA", versionEndExcluding: "01.01.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "1E0B32CC-8268-4B38-BBC7-51154882EC82", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "05B55989-A3E9-4AA1-A619-C75FEAA0B5DA", versionEndExcluding: "01.01.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "DA05435D-9A52-4D43-BE74-7D4C6C156AC6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "52156691-1368-4C77-98A7-EA63089091C5", versionEndExcluding: "01.01.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "5EE8B9B8-3C49-4296-9BC0-7E030878D479", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "EC052323-2E00-415D-847A-66F77AD5C3FD", versionEndExcluding: "01.01.01", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*", matchCriteriaId: "8F884CAF-D152-4318-B49B-0D68936D2BD9", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F4E035CB-0F76-47C0-B2C7-93AFA8A7B38B", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*", matchCriteriaId: "C6AEC7D6-7E5E-4CFF-99C8-7FBADA2479D5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E4CEE93A-9641-424B-AF55-2C550CA568F2", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*", matchCriteriaId: "00DDA679-D761-4986-A0A0-4C00178DF0B5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7D21A891-321B-42A3-8173-8E0743AEDD65", versionEndExcluding: "2.1.82", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*", matchCriteriaId: "EE0116F3-67FA-4129-B1FF-023774D179AF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "71BAF32C-35EA-4704-B75D-9EED01F8264B", versionEndExcluding: "1.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", matchCriteriaId: "581EA284-EDD6-4EA5-96B2-67904D1D9DC7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.", }, { lang: "es", value: "Los paquetes de difusión PROFINET DCP especialmente elaborados podrían causar una condición de denegación de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacción humana para recuperar los sistemas. Las interfaces PROFIBUS no están afectadas", }, ], id: "CVE-2017-2680", lastModified: "2024-11-21T03:23:57.563", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "ADJACENT_NETWORK", authentication: "NONE", availabilityImpact: "COMPLETE", baseScore: 6.1, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:A/AC:L/Au:N/C:N/I:N/A:C", version: "2.0", }, exploitabilityScore: 6.5, impactScore: 6.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "ADJACENT_NETWORK", availabilityImpact: "HIGH", baseScore: 6.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 2.8, impactScore: 3.6, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "ADJACENT_NETWORK", availabilityImpact: "HIGH", baseScore: 6.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 2.8, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], cvssMetricV40: [ { cvssData: { Automatable: "NOT_DEFINED", Recovery: "NOT_DEFINED", Safety: "NOT_DEFINED", attackComplexity: "LOW", attackRequirements: "NONE", attackVector: "ADJACENT", availabilityRequirement: "NOT_DEFINED", baseScore: 7.1, baseSeverity: "HIGH", confidentialityRequirement: "NOT_DEFINED", exploitMaturity: "NOT_DEFINED", integrityRequirement: "NOT_DEFINED", modifiedAttackComplexity: "NOT_DEFINED", modifiedAttackRequirements: "NOT_DEFINED", modifiedAttackVector: "NOT_DEFINED", modifiedPrivilegesRequired: "NOT_DEFINED", modifiedSubAvailabilityImpact: "NOT_DEFINED", modifiedSubConfidentialityImpact: "NOT_DEFINED", modifiedSubIntegrityImpact: "NOT_DEFINED", modifiedUserInteraction: "NOT_DEFINED", modifiedVulnAvailabilityImpact: "NOT_DEFINED", modifiedVulnConfidentialityImpact: "NOT_DEFINED", modifiedVulnIntegrityImpact: "NOT_DEFINED", privilegesRequired: "NONE", providerUrgency: "NOT_DEFINED", subAvailabilityImpact: "NONE", subConfidentialityImpact: "NONE", subIntegrityImpact: "NONE", userInteraction: "NONE", valueDensity: "NOT_DEFINED", vectorString: "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", version: "4.0", vulnAvailabilityImpact: "HIGH", vulnConfidentialityImpact: "NONE", vulnIntegrityImpact: "NONE", vulnerabilityResponseEffort: "NOT_DEFINED", }, source: "productcert@siemens.com", type: "Secondary", }, ], }, published: "2017-05-11T01:29:05.400", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/98369", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securitytracker.com/id/1038463", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-284673.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-546832.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02", }, { source: "productcert@siemens.com", tags: [ "Broken Link", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/98369", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securitytracker.com/id/1038463", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-284673.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-293562.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-546832.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Broken Link", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-400", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-400", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }