cve-2023-38380
Vulnerability from cvelistv5
Published
2023-12-12 11:26
Modified
2024-08-02 17:39
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:39:13.213Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.37",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210 (6SL5...)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.1 HF2",
              "status": "affected",
              "version": "V6.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.37",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions \u003c V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SINAMICS S210 (6SL5...) (All versions \u003e= V6.1 \u003c V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions \u003c V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-401",
              "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-11T14:19:50.234Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38380",
    "datePublished": "2023-12-12T11:26:36.173Z",
    "dateReserved": "2023-07-17T13:06:36.758Z",
    "dateUpdated": "2024-08-02T17:39:13.213Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-38380\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:11.477\",\"lastModified\":\"2024-06-11T12:15:10.630\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions \u003c V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SINAMICS S210 (6SL5...) (All versions \u003e= V6.1 \u003c V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions \u003c V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\\r\\n\\r\\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en:\\nSIMATIC CP 1242-7 V2 (incluidas las variantes SIPLUS) (todas las versiones), \\nSIMATIC CP 1243-1 (incluidas las variantes SIPLUS) (todas las versiones), \\nSIMATIC CP 1243-1 DNP3 (incluidas las variantes SIPLUS) ) (todas las versiones), \\nSIMATIC CP 1243-1 IEC (incl. variantes SIPLUS) (todas las versiones), \\nSIMATIC CP 1243-7 LTE (todas las versiones), \\nSIMATIC CP 1243-8 IRC (todas las versiones), \\nSIMATIC CP 1543-1 (Todas las versiones), \\nSINAMICS S210 (6SL5...) (Todas las versiones \u0026gt;= V6.1 \u0026lt; V6.1 HF2), \\nSIPLUS NET CP 1543-1 (Todas las versiones). \\nLa implementaci\u00f3n del servidor web de los productos afectados no libera correctamente la memoria asignada una vez utilizada. Un atacante con acceso a la red podr\u00eda utilizar esta vulnerabilidad para provocar una condici\u00f3n de denegaci\u00f3n de servicio en el servidor web del producto afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-401\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-401\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk7243-8rx30-0xe0_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BBBD0600-DB41-4DE8-97FC-2D180DA1406F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk7243-8rx30-0xe0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A50A52E7-D8FE-4071-99B3-3652B0892D07\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk7543-1ax00-0xe0_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF7C15EC-3C83-434B-A313-9035302EEF87\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk7543-1ax00-0xe0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E42E7B79-A3D2-4AAC-80E2-7E5C19A72CC5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6ag1543-1ax00-2xe0_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9373F60E-03D0-4EB2-9774-6479A8F342C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6ag1543-1ax00-2xe0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9063778-2B5F-4A32-83C8-6CEB9EE8F9C0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66A2C7F2-F787-4770-8F56-E2AFF1AFD780\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29D4C72C-4E84-4563-9D66-5C641AB996BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"373B769D-0E60-4362-BAE1-90BA6E0B211C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA9BB25C-D5E3-43DE-8C73-06BDC43CA960\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1158D559-2A46-4BE4-B16E-C2789AD3C60E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FFBFB96-1A35-4724-831B-68E3A9C32921\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C3E8B50-07E9-4697-B42D-86B9BE942553\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFE96226-A2DF-4A9E-8CBB-8D7CF328E404\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1243-7_lte_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FC29937-7A70-4A9F-89F8-8D17E285C225\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1243-7_lte:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BAFC3319-F07C-4784-9873-3E1907FE3080\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BEBF14B3-65A0-41E9-B99C-D88548F307CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"F151297C-3097-483F-98B5-0261BD547421\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1_hotfix8:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CEAB952-BBF0-4585-8F12-F25A192FAA1B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F4D3F85-4CA5-438E-955E-C039F7DE91B1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix2:*:*:*:*:*:*\",\"matchCriteriaId\":\"59608DD3-87C3-4ED1-B0C2-AFD31A7A70A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix5:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA3D3D7E-CB48-4B8D-8101-CB0DADEEC0B1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix6:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F8FC52F-3648-410B-8BCB-76129ABC0D4D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix7:*:*:*:*:*:*\",\"matchCriteriaId\":\"59BDCF31-2D94-4D7D-9EC8-60726B10DFC7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"D62C3EEA-000C-41CD-8264-4A4B6AE1BAD2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix3:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF00EE34-1A68-40F0-A9FC-FBBF268C6400\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix5:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6BB896A-8C42-416E-AE03-D5A0E122BA79\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*\",\"matchCriteriaId\":\"B18F1100-8157-4E99-AB22-BF51EB1663B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA9B1D54-E3A0-4EFF-8EB2-A52B8E1F117F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E509394F-9987-41D2-A866-68479FF39DCB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:hotfix1:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DEB162B-6579-4280-9BCC-403C1B351002\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BFA8FB3-12A9-4D2E-BCFD-C66313521C80\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-139628.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-625862.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-693975.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.