All the vulnerabilites related to siemens - sinamics_sm150_firmware
cve-2020-15798
Vulnerability from cvelistv5
Published
2021-02-09 15:38
Modified
2024-08-04 13:30
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) |
Version: All versions < V16 Update 3a |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:21.706Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T10:35:22", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15798", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15798", "datePublished": "2021-02-09T15:38:17", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:30:21.706Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6568
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.207Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.6" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RFID 181EIP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0 SP1 UPD1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF10" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SITOP Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T11:51:03.049Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6568", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27388
Vulnerability from cvelistv5
Published
2021-06-15 19:40
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | SINAMICS Medium Voltage Products, Remote Access |
Version: SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.713Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINAMICS Medium Voltage Products, Remote Access", "vendor": "n/a", "versions": [ { "status": "affected", "version": "SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "IMPROPER INPUT VALIDATION CWE-20", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-15T19:40:24", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27388", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINAMICS Medium Voltage Products, Remote Access", "version": { "version_data": [ { "version_value": "SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER INPUT VALIDATION CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27388", "datePublished": "2021-06-15T19:40:24", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.713Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27386
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-401", "description": "CWE-401: Missing Release of Memory after Effective Lifetime", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27386", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-401: Missing Release of Memory after Effective Lifetime" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27386", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.446Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27383
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.589Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-770: Allocation of Resources Without Limits or Throttling" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27383", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27385
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.474Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27385", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27385", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.474Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31337
Vulnerability from cvelistv5
Published
2021-06-28 12:24
Modified
2024-08-03 22:55
Severity ?
EPSS score ?
Summary
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | SINAMICS Medium Voltage Products |
Version: SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T22:55:53.698Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINAMICS Medium Voltage Products", "vendor": "n/a", "versions": [ { "status": "affected", "version": "SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T12:24:58", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31337", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINAMICS Medium Voltage Products", "version": { "version_data": [ { "version_value": "SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31337", "datePublished": "2021-06-28T12:24:58", "dateReserved": "2021-04-15T00:00:00", "dateUpdated": "2024-08-03T22:55:53.698Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27384
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:16", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27384", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27384", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podr\u00eda enviar paquetes especialmente dise\u00f1ados al manejador de dise\u00f1o de dispositivos SmartVNC en el lado del cliente, lo que podr\u00eda influir en la cantidad de recursos consumidos y dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio (bucle infinito)" } ], "id": "CVE-2021-27385", "lastModified": "2024-11-21T05:57:53.380", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.727", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-835" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC presenta una vulnerabilidad de fuga de asignaci\u00f3n de la pila en el manejador de dise\u00f1o del dispositivo en el lado del cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio" } ], "id": "CVE-2021-27386", "lastModified": "2024-11-21T05:57:53.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.767", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (with option X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC tiene una vulnerabilidad de fuga de asignaci\u00f3n de heap en el codificador Tight del servidor, que podr\u00eda dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio" } ], "id": "CVE-2021-27383", "lastModified": "2024-11-21T05:57:53.060", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.633", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-15 20:15
Modified
2024-11-21 05:57
Severity ?
Summary
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." }, { "lang": "es", "value": "Los productos enrutables de tensi\u00f3n media SINAMICS est\u00e1n afectados por una vulnerabilidad en el componente Sm@rtServer para el acceso remoto que podr\u00eda permitir a un atacante no autenticado causar una condici\u00f3n de denegaci\u00f3n de servicio, y/o una ejecuci\u00f3n de modificaciones de configuraci\u00f3n limitadas y/o la ejecuci\u00f3n de comandos de control limitados en los productos de media tensi\u00f3n SINAMICS, acceso remoto (SINAMICS SL150: Todas las versiones, SINAMICS SM150: Todas las versiones, SINAMICS SM150i: Todas las versiones)" } ], "id": "CVE-2021-27388", "lastModified": "2024-11-21T05:57:53.810", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-15T20:15:11.770", "references": [ { "source": "productcert@siemens.com", "tags": [ "Not Applicable" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-28 13:15
Modified
2024-11-21 06:05
Severity ?
Summary
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 | Not Applicable, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 | Not Applicable, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions)." }, { "lang": "es", "value": "El servicio Telnet del componente del sistema SIMATIC HMI Comfort Panels en los productos afectados no requiere autenticaci\u00f3n, lo que puede permitir a un atacante remoto conseguir acceso al dispositivo si el servicio est\u00e1 habilitado. Telnet est\u00e1 desactivado por defecto en los productos SINAMICS Medium Voltage (SINAMICS SL150: Todas las versiones, SINAMICS SM150: Todas las versiones, SINAMICS SM150i: Todas las versiones)" } ], "id": "CVE-2021-31337", "lastModified": "2024-11-21T06:05:26.710", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-28T13:15:20.840", "references": [ { "source": "productcert@siemens.com", "tags": [ "Not Applicable", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-09 17:15
Modified
2024-11-21 05:06
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels_firmware | 16.0 | |
siemens | simatic_hmi_comfort_panels_firmware | 16.0 | |
siemens | simatic_hmi_comfort_panels_firmware | 16.0 | |
siemens | simatic_hmi_comfort_panels_firmware | 16.0 | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16.0 | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16.0 | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16.0 | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16.0 | |
siemens | simatic_hmi_ktp_mobile_panels | - | |
siemens | sinamics_gh150_firmware | - | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | - | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | - | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sh150_firmware | - | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sl150_firmware | - | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm150_firmware | - | |
siemens | sinamics_sm150 | - | |
siemens | sinamics_sm120_firmware | - | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150i_firmware | - | |
siemens | sinamics_sm150i | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B7A9D84-336F-4CC3-B86D-1BC212726F3E", "versionEndExcluding": "16.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:-:*:*:*:*:*:*", "matchCriteriaId": "91E96941-4D8D-4473-8F6D-DE4D822DD245", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update1:*:*:*:*:*:*", "matchCriteriaId": "AFE4B793-1879-44A3-87B6-A86D7D687FD9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update2:*:*:*:*:*:*", "matchCriteriaId": "41238DBB-A315-498B-A8BC-54AB2EC0A9AF", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update3:*:*:*:*:*:*", "matchCriteriaId": "109E27B6-587F-4E21-9715-4FFBD43DC744", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50366ACE-B115-448C-A8B2-7903EB070CE7", "versionEndExcluding": "16.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:-:*:*:*:*:*:*", "matchCriteriaId": "BF124F76-F860-4A11-A358-292499D66629", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update1:*:*:*:*:*:*", "matchCriteriaId": "B4439C50-FFE9-485E-BD82-7896959E04B2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update2:*:*:*:*:*:*", "matchCriteriaId": "7AE2A346-C42B-4B70-8FA8-1B56D9603114", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update3:*:*:*:*:*:*", "matchCriteriaId": "96414026-2404-4AFD-B55C-1CD93F729110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "04A1F440-A20A-43BF-8B92-A32F355311DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E108020-A6BA-4C90-BB0A-6E80F3341731", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFC05D55-994D-4F54-AA17-FB4D3A0191A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9CD365F-139E-42D9-8B1E-31A07E752226", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AFBC5A7-6DED-4237-8ACC-D0C4C582DE7E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F587131C-64F3-4B89-902C-809B5F095BF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1915386C-8C70-479B-B9AE-2A970CD773C0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels (incl. Variantes SIPLUS) (Todas las versiones anteriores a V16 Update 3a), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a V16 Update 3a), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Los dispositivos afectados con el servicio telnet activado no requieren autenticaci\u00f3n para este servicio. Esto podr\u00eda permitir a un atacante remoto obtener acceso completo al dispositivo. (ZDI-CAN-12046)" } ], "id": "CVE-2020-15798", "lastModified": "2024-11-21T05:06:12.120", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-09T17:15:13.437", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | cp1604_firmware | * | |
siemens | cp1604 | - | |
siemens | cp1616_firmware | * | |
siemens | cp1616 | - | |
siemens | simatic_rf185c_firmware | * | |
siemens | simatic_rf185c | - | |
siemens | simatic_cp343-1_advanced_firmware | * | |
siemens | simatic_cp343-1_advanced | - | |
siemens | simatic_cp443-1_firmware | * | |
siemens | simatic_cp443-1 | - | |
siemens | simatic_cp443-1_advanced_firmware | * | |
siemens | simatic_cp443-1_advanced | - | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware | * | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc | - | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware | * | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc2 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_cp443-1_opc_ua | * | |
siemens | simatic_ipc_diagmonitor | * | |
siemens | simatic_s7-1500_software_controller | * | |
siemens | simatic_s7-plcsim_advanced | * | |
siemens | simatic_s7-plcsim_advanced | 2.0 | |
siemens | simatic_s7-plcsim_advanced | 2.0 | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | sitop_manager | * | |
siemens | simatic_rf600r_firmware | * | |
siemens | simatic_rf600r | - | |
siemens | simatic_rf188c_firmware | * | |
siemens | simatic_rf188c | - | |
siemens | simatic_rf186c_firmware | * | |
siemens | simatic_rf186c | - | |
siemens | simatic_rf182c_firmware | * | |
siemens | simatic_rf182c | - | |
siemens | simatic_rf181-eip_firmware | * | |
siemens | simatic_rf181-eip | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_s7-300_firmware | * | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_pn_firmware | * | |
siemens | simatic_s7-400_pn | - | |
siemens | simatic_s7-400_pn\/dp_firmware | * | |
siemens | simatic_s7-400_pn\/dp | - | |
siemens | simatic_teleservice_adapter_ie_advanced_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced | - | |
siemens | simatic_teleservice_adapter_ie_basic_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic | - | |
siemens | simatic_teleservice_adapter_ie_standard_firmware | * | |
siemens | simatic_teleservice_adapter_ie_standard | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | simocode_pro_v_eip_firmware | * | |
siemens | simocode_pro_v_eip | - | |
siemens | simocode_pro_v_pn_firmware | * | |
siemens | simocode_pro_v_pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150 | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_s210_firmware | * | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210 | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | sitop_ups1600_firmware | * | |
siemens | sitop_ups1600 | - | |
siemens | tim_1531_irc_firmware | * | |
siemens | tim_1531_irc | - | |
siemens | simatic_s7-1500f_firmware | * | |
siemens | simatic_s7-1500f | - | |
siemens | simatic_s7-1500s_firmware | * | |
siemens | simatic_s7-1500s | - | |
siemens | simatic_s7-1500t_firmware | * | |
siemens | simatic_s7-1500t | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150_firmware | 4.8 | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.8 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.8 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120_firmware | 4.8 | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150_firmware | 5.1 | |
siemens | sinamics_sm150 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E737620D-9D00-4151-B232-7DFB7FD768B3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6222006F-09D7-49F7-B8C7-4D94298A8F6A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65FE6F54-1457-4EB6-9273-1D93B3B97386", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "184365A2-BAD2-4926-ACEE-F71E018D3CE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "69EE2BF6-3846-478F-9AC6-BEF34617F3B5", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E6601B8-E032-4B39-BF65-F25CF047EB99", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp343-1_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "ACCC0229-E454-4BEF-931A-3CD820500822", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2035A020-F41E-4FC7-A290-9923574D4921", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp443-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB8636E9-A3DA-4DDC-A3FC-B3EAAD07952E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AD15638-8B84-4DA2-9DDC-9A1CA3548E91", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFE94F56-71DB-4837-9818-6827C80DE2BC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1873751-81F4-4732-B30F-9F2DEECBC110", "versionEndExcluding": "2.1.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F36AC571-C958-4CB8-91D9-5417C1812C02", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", "matchCriteriaId": "00361A3C-60E9-4365-BB51-09D7792C441D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "865FD012-F390-4BB8-B14F-533840B95512", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5418D916-49A6-4B79-A653-E2C5221DEBE8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*", "matchCriteriaId": "56396833-12BF-4AE5-8D3E-695652A99DBF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FD49A39-47D7-473C-9E46-6D9246BC6D04", "versionEndExcluding": "5.1.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "11C0A94D-5506-4A75-99E1-CA9769AF057C", "versionEndExcluding": "2.7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B66A2A4-5062-45F8-A615-2DA716650909", "versionEndExcluding": "2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*", "matchCriteriaId": "AED3A3AF-EF77-4E58-91AD-BBE01E1DA4A6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "23039930-E45C-4B0E-883A-E2F9A7502984", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "2662688E-6975-46C7-939B-25FF4790518D", "versionEndExcluding": "1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16CBED3D-892A-4EC0-BE2E-358040C34304", "versionEndExcluding": "3.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25F96DAA-696D-4EB4-97DF-986C7681700B", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF8FFD1C-8E33-48E9-A884-B80311F8BA4C", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", "matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFA94867-4367-4186-8A4B-44C3CBCCEF7F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf181-eip:-:*:*:*:*:*:*:*", "matchCriteriaId": "E10A0D57-8805-44DB-95E3-1B240ED5ED09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AE766CD-695B-4A12-8BC5-3743D8E3D73E", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A2219FE-2C3F-4948-85D6-3C53AC08722B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "795D0FF9-1D0B-4C74-BEF3-58EAE74DFA0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC917346-94F6-44FD-AC00-AED0CF3CBBD1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "F60D816D-85A5-4971-AF2D-666AE0B74E9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "71DA3D1A-E435-418F-9A13-945B4BA15FC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*", "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_eip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A001968-C7FD-4C11-8439-11532B234CC2", "versionEndExcluding": "1.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_eip:-:*:*:*:*:*:*:*", "matchCriteriaId": "50BDA360-0D33-42DC-ADB9-2F69503C2CD8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15CB26DA-7CA0-4BD6-A219-01F6E8A6F03F", "versionEndExcluding": "2.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "1779AE78-AC90-48BE-8FF2-CC11E7CA3CB4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", "versionEndExcluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "126AC93E-A39F-4754-9707-207C9F2F64F4", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "3E8BCCED-BDC6-4785-8705-799836E5024E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "098262CC-4D3B-4E55-83C3-2816403C553B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1_hotfix2:*:*:*:*:*:*", "matchCriteriaId": "6092F899-9A89-4FA4-BD80-97511DF7CF8F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7269713-6505-41DF-B85B-F729E24A3F5B", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "BEBF14B3-65A0-41E9-B99C-D88548F307CD", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "F151297C-3097-483F-98B5-0261BD547421", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*", "matchCriteriaId": "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F389808-001E-4650-86B2-00A72D25BCD0", "versionEndExcluding": "1.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_ups1600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD39CC96-ABE3-4854-A102-36AFE1F6CB14", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_ups1600:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FC1A64E-6A27-4F91-8A13-829E0F7D8E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B023E75A-B76D-4FD8-9660-1F233092160F", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9C47A4A-BE81-499A-AB36-491661B88693", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*", "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66A446D2-39ED-4635-AAA0-85D977F600FE", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5238622A-BCAD-4A06-9920-49BECFDDC2A6", "versionEndExcluding": "2.6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*", "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "6D076504-AFE3-4C51-80E5-C5992CA7D511", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC70D596-AA1E-4196-87B0-BECEE6568AA7", "versionEndExcluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:5.1:-:*:*:*:*:*:*", "matchCriteriaId": "1E81CDB5-122F-48D1-B9F1-4C401D46D978", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." }, { "lang": "es", "value": "SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" - 22\" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 y variantes SIPLUS), controlador de software SIMATIC S7-1500, familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incluidas las variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incluidas las variantes SIPLUS) SIPLUS), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS), SIMOCODE pro V PN (incl. variantes SIPLUS), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5. 1 SP1 Unidad de control, SINAMICS G150 V4.6 Unidad de control, SINAMICS G150 V4.7 Unidad de control, SINAMICS G150 V4.7 SP1 Unidad de control, SINAMICS G150 V4.8 Unidad de control, SINAMICS G150 V5. 1 Unidad de control, SINAMICS G150 V5.1 SP1 Unidad de control, SINAMICS GH150 V4.7 (Unidad de control), SINAMICS GH150 V4.8 (Unidad de control), SINAMICS GL150 V4.7 (Unidad de control), SINAMICS GL150 V4. 8 (Unidad de control), SINAMICS GM150 V4.7 (Unidad de control), SINAMICS GM150 V4.8 (Unidad de control), SINAMICS S120 V4.6 Unidad de control (incl. variantes SIPLUS), SINAMICS S120 V4.7 Unidad de control (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V4.7 SP1 (incl. variantes SIPLUS), SINAMICS S120 V4.8 (incl. variantes SIPLUS), SINAMICS S120 V5.1 (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V5.1 SP1 Unidad de Control (incl. variantes SIPLUS), SINAMICS S150 V4.6 Unidad de Control, SINAMICS S150 V4.7 Unidad de Control, SINAMICS S150 V4.7 SP1 Unidad de Control, SINAMICS S150 V4. 8 Unidad de control, SINAMICS S150 V5.1 Unidad de control, SINAMICS S150 V5.1 SP1 Unidad de control, SINAMICS S210 V5.1 Unidad de control, SINAMICS S210 V5.1 SP1 Unidad de control, SINAMICS SL150 V4. 7 (Unidad de Control), SINAMICS SL150 V4.8 (Unidad de Control), SINAMICS SM120 V4.7 (Unidad de Control), SINAMICS SM120 V4.8 (Unidad de Control), SINAMICS SM150 V4. 8 (unidad de control), SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. variantes SIPLUS), TIM 1531 IRC (incl. variantes SIPLUS NET). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Un atacante puede provocar una situaci\u00f3n de denegaci\u00f3n de servicio que lleve a reiniciar el servidor web del dispositivo afectado. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo" } ], "id": "CVE-2019-6568", "lastModified": "2024-11-21T04:46:42.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2019-04-17T14:29:03.683", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones anteriores), SINAMICS GL150 (with option X30) (Todas las versiones anteriores), SINAMICS GM150 (with option X30) (Todas las versiones anteriores), SINAMICS SH150 (Todas las versiones anteriores), SINAMICS SL150 (Todas las versiones anteriores), SINAMICS SM120 (Todas las versiones anteriores), SINAMICS SM150 (Todas las versiones anteriores), SINAMICS SM150i (Todas las versiones anteriores). SmartVNC tiene una vulnerabilidad de acceso a memoria fuera de l\u00edmites en el manejador de dise\u00f1o del dispositivo, representado por un flujo de datos binarios en el lado del cliente, que potencialmente puede resultar en la ejecuci\u00f3n de c\u00f3digo" } ], "id": "CVE-2021-27384", "lastModified": "2024-11-21T05:57:53.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.677", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }