All the vulnerabilites related to siemens - siplus_net_cp_1242-7_v2_firmware
cve-2022-34820
Vulnerability from cvelistv5
Published
2022-07-12 10:07
Modified
2024-08-03 09:22
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1243-1 Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE EU Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE US Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V3.3.46
Siemens SIMATIC CP 1542SP-1 IRC Version: All versions >= V2.0 < V2.2.28
Siemens SIMATIC CP 1543-1 Version: All versions < V3.0.22
Siemens SIMATIC CP 1543SP-1 Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS NET CP 1242-7 V2 Version: All versions < V3.3.46
Siemens SIPLUS NET CP 1543-1 Version: All versions < V3.0.22
Siemens SIPLUS S7-1200 CP 1243-1 Version: All versions < V3.3.46
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: All versions < V3.3.46
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:39.103Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34820",
    "datePublished": "2022-07-12T10:07:29",
    "dateReserved": "2022-06-29T00:00:00",
    "dateUpdated": "2024-08-03T09:22:10.675Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-34819
Vulnerability from cvelistv5
Published
2022-07-12 10:07
Modified
2024-08-03 09:22
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1243-1 Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE EU Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE US Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V3.3.46
Siemens SIMATIC CP 1542SP-1 IRC Version: All versions >= V2.0 < V2.2.28
Siemens SIMATIC CP 1543-1 Version: All versions < V3.0.22
Siemens SIMATIC CP 1543SP-1 Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: All versions >= V2.0 < V2.2.28
Siemens SIPLUS NET CP 1242-7 V2 Version: All versions < V3.3.46
Siemens SIPLUS NET CP 1543-1 Version: All versions < V3.0.22
Siemens SIPLUS S7-1200 CP 1243-1 Version: All versions < V3.3.46
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: All versions < V3.3.46
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:37.921Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34819",
    "datePublished": "2022-07-12T10:07:27",
    "dateReserved": "2022-06-29T00:00:00",
    "dateUpdated": "2024-08-03T09:22:10.546Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43767
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2024-09-10 09:33
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1243-1 Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE EU Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE US Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-8 IRC Version: 0   < V3.4.29
Siemens SIMATIC CP 1542SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 1542SP-1 IRC Version: 0   < V2.3
Siemens SIMATIC CP 1543SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: 0   < V2.3
Siemens SIPLUS NET CP 1242-7 V2 Version: 0   < V3.4.29
Siemens SIPLUS NET CP 443-1 Version: 0   < V3.3
Siemens SIPLUS NET CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS S7-1200 CP 1243-1 Version: 0   < V3.4.29
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: 0   < V3.4.29
Siemens SIPLUS TIM 1531 IRC Version: 0   < V2.3.6
Siemens TIM 1531 IRC Version: 0   < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43767",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-12T19:11:06.737320Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-12T20:11:32.129Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.317Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-833",
              "description": "CWE-833: Deadlock",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:33.351Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43767",
    "datePublished": "2023-04-11T09:02:50.497Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2024-09-10T09:33:33.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43768
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2024-09-10 09:33
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1243-1 Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE EU Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE US Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-8 IRC Version: 0   < V3.4.29
Siemens SIMATIC CP 1542SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 1542SP-1 IRC Version: 0   < V2.3
Siemens SIMATIC CP 1543SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: 0   < V2.3
Siemens SIPLUS NET CP 1242-7 V2 Version: 0   < V3.4.29
Siemens SIPLUS NET CP 443-1 Version: 0   < V3.3
Siemens SIPLUS NET CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS S7-1200 CP 1243-1 Version: 0   < V3.4.29
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: 0   < V3.4.29
Siemens SIPLUS TIM 1531 IRC Version: 0   < V2.3.6
Siemens TIM 1531 IRC Version: 0   < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:34.861Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43768",
    "datePublished": "2023-04-11T09:02:51.623Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2024-09-10T09:33:34.861Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43716
Vulnerability from cvelistv5
Published
2023-04-11 09:02
Modified
2024-09-10 09:33
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1243-1 Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE EU Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-7 LTE US Version: 0   < V3.4.29
Siemens SIMATIC CP 1243-8 IRC Version: 0   < V3.4.29
Siemens SIMATIC CP 1542SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 1542SP-1 IRC Version: 0   < V2.3
Siemens SIMATIC CP 1543SP-1 Version: 0   < V2.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: 0   < V2.3
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: 0   < V2.3
Siemens SIPLUS NET CP 1242-7 V2 Version: 0   < V3.4.29
Siemens SIPLUS NET CP 443-1 Version: 0   < V3.3
Siemens SIPLUS NET CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS S7-1200 CP 1243-1 Version: 0   < V3.4.29
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: 0   < V3.4.29
Siemens SIPLUS TIM 1531 IRC Version: 0   < V2.3.6
Siemens TIM 1531 IRC Version: 0   < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_gprs_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:12:55.560896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T14:35:43.227Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:31.854Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43716",
    "datePublished": "2023-04-11T09:02:49.383Z",
    "dateReserved": "2022-10-24T05:19:12.272Z",
    "dateUpdated": "2024-09-10T09:33:31.854Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-34821
Vulnerability from cvelistv5
Published
2022-07-12 00:00
Modified
2025-01-14 10:26
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V7.2
Siemens SCALANCE M804PB Version: 0   < V7.2
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V7.2
Siemens SCALANCE M874-2 Version: 0   < V7.2
Siemens SCALANCE M874-3 Version: 0   < V7.2
Siemens SCALANCE M876-3 Version: 0   < V7.2
Siemens SCALANCE M876-3 (ROK) Version: 0   < V7.2
Siemens SCALANCE M876-4 Version: 0   < V7.2
Siemens SCALANCE M876-4 (EU) Version: 0   < V7.2
Siemens SCALANCE M876-4 (NAM) Version: 0   < V7.2
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V7.2
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V7.2
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V7.2
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V7.2
Siemens SCALANCE S615 LAN-Router Version: 0   < V7.2
Siemens SCALANCE SC622-2C Version: 0   < V2.3
Siemens SCALANCE SC622-2C Version: V2.3   < V3.0
Siemens SCALANCE SC626-2C Version: 0   < V2.3
Siemens SCALANCE SC626-2C Version: V2.3   < V3.0
Siemens SCALANCE SC632-2C Version: 0   < V2.3
Siemens SCALANCE SC632-2C Version: V2.3   < V3.0
Siemens SCALANCE SC636-2C Version: 0   < V2.3
Siemens SCALANCE SC636-2C Version: V2.3   < V3.0
Siemens SCALANCE SC642-2C Version: 0   < V2.3
Siemens SCALANCE SC642-2C Version: V2.3   < V3.0
Siemens SCALANCE SC646-2C Version: 0   < V2.3
Siemens SCALANCE SC646-2C Version: V2.3   < V3.0
Siemens SCALANCE WAB762-1 Version: 0   < V3.0.0
Siemens SCALANCE WAM763-1 Version: 0   < V3.0.0
Siemens SCALANCE WAM763-1 (ME) Version: 0   < V3.0.0
Siemens SCALANCE WAM763-1 (US) Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 (ME) Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 (US) Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 EEC Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 EEC (ME) Version: 0   < V3.0.0
Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < V3.0.0
Siemens SCALANCE WUB762-1 Version: 0   < V3.0.0
Siemens SCALANCE WUB762-1 iFeatures Version: 0   < V3.0.0
Siemens SCALANCE WUM763-1 Version: 0   < V3.0.0
Siemens SCALANCE WUM763-1 Version: 0   < V3.0.0
Siemens SCALANCE WUM763-1 (US) Version: 0   < V3.0.0
Siemens SCALANCE WUM763-1 (US) Version: 0   < V3.0.0
Siemens SCALANCE WUM766-1 Version: 0   < V3.0.0
Siemens SCALANCE WUM766-1 (ME) Version: 0   < V3.0.0
Siemens SCALANCE WUM766-1 (USA) Version: 0   < V3.0.0
Siemens SIMATIC CP 1242-7 V2 Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-1 Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE EU Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-7 LTE US Version: All versions < V3.3.46
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V3.3.46
Siemens SIMATIC CP 1542SP-1 IRC Version: V2.0   < V2.2.28
Siemens SIMATIC CP 1543-1 Version: All versions < V3.0.22
Siemens SIMATIC CP 1543SP-1 Version: V2.0   < V2.2.28
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Version: V2.0   < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Version: V2.0   < V2.2.28
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Version: V2.0   < V2.2.28
Siemens SIPLUS NET CP 1242-7 V2 Version: All versions < V3.3.46
Siemens SIPLUS NET CP 1543-1 Version: All versions < V3.0.22
Siemens SIPLUS S7-1200 CP 1243-1 Version: All versions < V3.3.46
Siemens SIPLUS S7-1200 CP 1243-1 RAIL Version: All versions < V3.3.46
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.733Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1 iFeatures",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:26:58.220Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34821",
    "datePublished": "2022-07-12T00:00:00",
    "dateReserved": "2022-06-29T00:00:00",
    "dateUpdated": "2025-01-14T10:26:58.220Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-07-12 10:15
Modified
2024-11-21 07:10
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). La aplicaci\u00f3n carece de una validaci\u00f3n adecuada de los datos suministrados por el usuario al analizar mensajes espec\u00edficos. Esto podr\u00eda dar lugar a un desbordamiento del b\u00fafer basado en la pila. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del dispositivo"
    }
  ],
  "id": "CVE-2022-34819",
  "lastModified": "2024-11-21T07:10:14.917",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-07-12T10:15:12.293",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Impacted products
Vendor Product Version
siemens simatic_cp_1242-7_v2_firmware *
siemens simatic_cp_1242-7_v2 -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-7_lte_eu_firmware *
siemens simatic_cp_1243-7_lte_eu -
siemens simatic_cp_1243-7_lte_us_firmware *
siemens simatic_cp_1243-7_lte_us -
siemens simatic_cp_1243-8_irc_firmware *
siemens simatic_cp_1243-8_irc -
siemens simatic_cp_1542sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_443-1_firmware *
siemens simatic_cp_443-1 -
siemens simatic_cp_443-1_advanced_firmware *
siemens simatic_cp_443-1_advanced -
siemens simatic_ipc_diagbase_firmware *
siemens simatic_ipc_diagbase -
siemens simatic_ipc_diagmonitor_firmware *
siemens simatic_ipc_diagmonitor -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens siplus_net_cp_1242-7_v2_firmware *
siemens siplus_net_cp_1242-7_v2 -
siemens siplus_net_cp_443-1_firmware *
siemens siplus_net_cp_443-1 -
siemens siplus_net_cp_443-1_advanced_firmware *
siemens siplus_net_cp_443-1_advanced -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_tim_1531_irc_firmware *
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1F51B86-57EE-4DB6-B038-06726BC93D2D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8648EF79-043D-48DE-B9F8-BF762862EE99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C8B5C37-200C-4531-8876-3E05F3DE3EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCDA714C-5851-4E35-806F-E0C651A1E87A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F58423D0-954E-426E-9F8F-3DD95FBDF50C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "530FD06D-E020-4EB3-87DD-F7B2FEE58008",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8784BA58-12BF-4F1C-94D6-2D15933703C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE009635-7EC7-4A2F-B1FA-DD75213A25CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9054A7B6-9569-4D65-9695-A0FFA4F56C74",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F488C27-C8B9-4238-8409-AB7ACA3BC849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45B95689-C355-4CF1-AE7A-0860E4CEA11A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21F04D79-5815-4D36-8AA5-4866751D0DDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2498071A-6540-4147-8D01-3B81A5CE9A57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C616E50-1F96-4A87-8470-1BA8732FCB77",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
    }
  ],
  "id": "CVE-2022-43767",
  "lastModified": "2024-11-21T07:27:11.520",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-04-11T10:15:17.540",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-833"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Impacted products
Vendor Product Version
siemens simatic_cp_1242-7_v2_firmware *
siemens simatic_cp_1242-7_v2 -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-7_lte_eu_firmware *
siemens simatic_cp_1243-7_lte_eu -
siemens simatic_cp_1243-7_lte_us_firmware *
siemens simatic_cp_1243-7_lte_us -
siemens simatic_cp_1243-8_irc_firmware *
siemens simatic_cp_1243-8_irc -
siemens simatic_cp_1542sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_443-1_firmware *
siemens simatic_cp_443-1 -
siemens simatic_cp_443-1_advanced_firmware *
siemens simatic_cp_443-1_advanced -
siemens simatic_ipc_diagbase_firmware *
siemens simatic_ipc_diagbase -
siemens simatic_ipc_diagmonitor_firmware *
siemens simatic_ipc_diagmonitor -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens siplus_net_cp_1242-7_v2_firmware *
siemens siplus_net_cp_1242-7_v2 -
siemens siplus_net_cp_443-1_firmware *
siemens siplus_net_cp_443-1 -
siemens siplus_net_cp_443-1_advanced_firmware *
siemens siplus_net_cp_443-1_advanced -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_tim_1531_irc_firmware *
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1F51B86-57EE-4DB6-B038-06726BC93D2D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8648EF79-043D-48DE-B9F8-BF762862EE99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C8B5C37-200C-4531-8876-3E05F3DE3EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCDA714C-5851-4E35-806F-E0C651A1E87A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F58423D0-954E-426E-9F8F-3DD95FBDF50C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "530FD06D-E020-4EB3-87DD-F7B2FEE58008",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8784BA58-12BF-4F1C-94D6-2D15933703C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE009635-7EC7-4A2F-B1FA-DD75213A25CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9054A7B6-9569-4D65-9695-A0FFA4F56C74",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F488C27-C8B9-4238-8409-AB7ACA3BC849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45B95689-C355-4CF1-AE7A-0860E4CEA11A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21F04D79-5815-4D36-8AA5-4866751D0DDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2498071A-6540-4147-8D01-3B81A5CE9A57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C616E50-1F96-4A87-8470-1BA8732FCB77",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
    }
  ],
  "id": "CVE-2022-43768",
  "lastModified": "2024-11-21T07:27:11.733",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-04-11T10:15:17.617",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-07-12 10:15
Modified
2025-01-14 11:15
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). Al inyectar c\u00f3digo a opciones de configuraci\u00f3n espec\u00edficas para OpenVPN, un atacante podr\u00eda ejecutar c\u00f3digo arbitrario con privilegios elevados"
    }
  ],
  "id": "CVE-2022-34821",
  "lastModified": "2025-01-14T11:15:10.343",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.0,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "ADJACENT",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "HIGH",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "HIGH",
          "subsequentSystemConfidentiality": "HIGH",
          "subsequentSystemIntegrity": "HIGH",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "HIGH"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-07-12T10:15:12.393",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-04-11 10:15
Modified
2024-11-21 07:27
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Impacted products
Vendor Product Version
siemens simatic_cp_1242-7_v2_firmware *
siemens simatic_cp_1242-7_v2 -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-7_lte_eu_firmware *
siemens simatic_cp_1243-7_lte_eu -
siemens simatic_cp_1243-7_lte_us_firmware *
siemens simatic_cp_1243-7_lte_us -
siemens simatic_cp_1243-8_irc_firmware *
siemens simatic_cp_1243-8_irc -
siemens simatic_cp_1542sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_443-1_firmware *
siemens simatic_cp_443-1 -
siemens simatic_cp_443-1_advanced_firmware *
siemens simatic_cp_443-1_advanced -
siemens simatic_ipc_diagbase_firmware *
siemens simatic_ipc_diagbase -
siemens simatic_ipc_diagmonitor_firmware *
siemens simatic_ipc_diagmonitor -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens siplus_net_cp_1242-7_v2_firmware *
siemens siplus_net_cp_1242-7_v2 -
siemens siplus_net_cp_443-1_firmware *
siemens siplus_net_cp_443-1 -
siemens siplus_net_cp_443-1_advanced_firmware *
siemens siplus_net_cp_443-1_advanced -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_tim_1531_irc_firmware *
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1F51B86-57EE-4DB6-B038-06726BC93D2D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8648EF79-043D-48DE-B9F8-BF762862EE99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C8B5C37-200C-4531-8876-3E05F3DE3EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCDA714C-5851-4E35-806F-E0C651A1E87A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F58423D0-954E-426E-9F8F-3DD95FBDF50C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "418A9C80-BEFD-4A1F-B1BB-6C45A9267A44",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagbase_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "530FD06D-E020-4EB3-87DD-F7B2FEE58008",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8784BA58-12BF-4F1C-94D6-2D15933703C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE009635-7EC7-4A2F-B1FA-DD75213A25CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9054A7B6-9569-4D65-9695-A0FFA4F56C74",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F488C27-C8B9-4238-8409-AB7ACA3BC849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45B95689-C355-4CF1-AE7A-0860E4CEA11A",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21F04D79-5815-4D36-8AA5-4866751D0DDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94CC55CF-9BA3-4BE7-9654-F6B6C4F0DA62",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2498071A-6540-4147-8D01-3B81A5CE9A57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C616E50-1F96-4A87-8470-1BA8732FCB77",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4646AF8C-B871-4F9E-85A4-ECE8F13AFB21",
              "versionEndExcluding": "2.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
    }
  ],
  "id": "CVE-2022-43716",
  "lastModified": "2024-11-21T07:27:07.160",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-04-11T10:15:17.467",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-07-12 10:15
Modified
2024-11-21 07:10
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DB5A20B-3FFD-46DE-A838-D5121AD8CA05",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E20882A0-3D80-45C0-BB83-A064A5D27483",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F0F009F-A744-40E7-910E-2789BF16648D",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80C6BD76-99C6-4D27-9CCA-ED0915DEFB5B",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA4FF14E-2CDA-4A28-BB9E-217AD3C808DB",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F6C0C17-BDD5-4503-9D8C-3143C6074705",
              "versionEndExcluding": "2.2.28",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE0A05A9-E1E0-475F-953D-61AC673BF3C4",
              "versionEndExcluding": "2.2.28",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B815C6C6-FDE0-404A-8492-27519909A6C3",
              "versionEndExcluding": "2.2.28",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B1C1F68-AE3D-47EB-9370-B2FE3F07C3C2",
              "versionEndExcluding": "2.2.28",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3ED5D3BC-ABD7-493D-8998-C1B5F17B3C24",
              "versionEndExcluding": "2.2.28",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FD90115-FA81-4880-B05B-0FEA9FA51C71",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "27851880-F35C-495E-8DFF-CB3D03CED376",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0C64F3D-FEBC-4AB4-9FCF-19B59F9BF5A3",
              "versionEndExcluding": "3.3.46",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). La aplicaci\u00f3n no escapa correctamente de algunos campos proporcionados por el usuario durante el proceso de autenticaci\u00f3n. Esto podr\u00eda permitir a un atacante inyectar comandos personalizados y ejecutar c\u00f3digo arbitrario con privilegios elevados"
    }
  ],
  "id": "CVE-2022-34820",
  "lastModified": "2024-11-21T07:10:15.080",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-07-12T10:15:12.343",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-116"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}