    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from nvd – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-31 16:32 UTC
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:38 UTC
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:50 UTC
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:51 UTC
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from cvelistv5 – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-31 16:32 UTC
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:50 UTC
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:51 UTC
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-28 14:38 UTC
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }