Search criteria

38 vulnerabilities found for v-simulator by fujielectric

VAR-202101-1105

Vulnerability from variot - Updated: 2023-12-18 11:48

A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-1105",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22641",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-22641",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17707",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22641",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22641",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-22641",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22641",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17707",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2393",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22641",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files.  The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer.  An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22641",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-099",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11669",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "id": "VAR-202101-1105",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:48:01.766000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17707)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/252926"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-099/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22641"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "date": "2021-01-27T20:15:13.207000",
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-099"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17707"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22641"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      },
      {
        "date": "2022-04-26T16:14:21.717000",
        "db": "NVD",
        "id": "CVE-2021-22641"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002821"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2393"
      }
    ],
    "trust": 0.6
  }
}

VAR-202101-0897

Vulnerability from variot - Updated: 2023-12-18 11:47

Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment.

Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds write vulnerability, which can be exploited by attackers to execute arbitrary code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0897",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "cve": "CVE-2021-22653",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-22653",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17709",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22653",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-22653",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17709",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2401",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22653",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment. \n\r\n\r\nFuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds write vulnerability, which can be exploited by attackers to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "id": "VAR-202101-0897",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:47:55.500000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite out-of-bounds write vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/252821"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22653"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "date": "2021-01-27T20:15:13.317000",
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17709"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      },
      {
        "date": "2021-01-29T16:11:19.563000",
        "db": "NVD",
        "id": "CVE-2021-22653"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002822"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2401"
      }
    ],
    "trust": 0.6
  }
}

VAR-202101-1104

Vulnerability from variot - Updated: 2023-12-18 11:18

An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-1104",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22639",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-22639",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17708",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22639",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22639",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-22639",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22639",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17708",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2398",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22639",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22639",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-098",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11668",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "id": "VAR-202101-1104",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:18:29.815000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17708)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/252906"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-824",
        "trust": 1.0
      },
      {
        "problemtype": "Accessing uninitialized pointers (CWE-824) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-098/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22639"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/824.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195684"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "date": "2021-01-27T20:15:12.847000",
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-098"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17708"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22639"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      },
      {
        "date": "2021-01-29T15:49:24.803000",
        "db": "NVD",
        "id": "CVE-2021-22639"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Vulnerability in accessing uninitialized pointers in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002820"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2398"
      }
    ],
    "trust": 0.6
  }
}

VAR-202101-1103

Vulnerability from variot - Updated: 2023-12-18 11:16

Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-1103",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "v-server lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Anonymous",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-22637",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-22637",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17711",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22637",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-22637",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-22637",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-22637",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17711",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2406",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22637",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite.  User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files.  The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22637",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-097",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11170",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "id": "VAR-202101-1103",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:16:56.562000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/252811"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 2.5,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-097/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22637"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "date": "2021-01-27T20:15:12.770000",
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-097"
      },
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17711"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22637"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      },
      {
        "date": "2022-04-26T16:14:06.040000",
        "db": "NVD",
        "id": "CVE-2021-22637"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002819"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2406"
      }
    ],
    "trust": 0.6
  }
}

VAR-202101-0898

Vulnerability from variot - Updated: 2023-12-18 10:51

Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds read.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment.

Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds read vulnerability. Attackers can use this vulnerability to execute arbitrary code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0898",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "v-simulator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.10.0"
      },
      {
        "model": "v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "lite 4.0.10.0"
      },
      {
        "model": "v-server",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric tellus lite v-simulator",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      },
      {
        "model": "electric v-server lite",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "4.0.10.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "cve": "CVE-2021-22655",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-22655",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2021-17710",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-22655",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-22655",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-17710",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2403",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-22655",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds read.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. Fuji Electric Tellus Lite V-Simulator is a remote monitoring software for industrial environments. Fuji Electric V-Server Lite is a remote monitoring software for industrial environments. The software can collect information about PLCs, temperature controllers, inverters and other equipment. \n\r\n\r\nFuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite have an out-of-bounds read vulnerability. Attackers can use this vulnerability to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22655",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-026-01",
        "trust": 3.1
      },
      {
        "db": "JVN",
        "id": "JVNVU93293369",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0297",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "id": "VAR-202101-0898",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      }
    ],
    "trust": 1.53529412
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      }
    ]
  },
  "last_update_date": "2023-12-18T10:51:42.491000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.fujielectric.com/index.html"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite out-of-bounds read vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/252816"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds read (CWE-125) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22655"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu93293369/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/125.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "date": "2021-01-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-10-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "date": "2021-01-27T20:15:13.397000",
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-01-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17710"
      },
      {
        "date": "2021-01-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-10-05T08:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      },
      {
        "date": "2021-01-29T15:49:41.037000",
        "db": "NVD",
        "id": "CVE-2021-22655"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds read vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002823"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2403"
      }
    ],
    "trust": 0.6
  }
}

FKIE_CVE-2021-38419

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a una escritura fuera de l\u00edmites, que puede resultar en una corrupci\u00f3n de datos, a un bloqueo del sistema o a una ejecuci\u00f3n de c\u00f3digo"
    }
  ],
  "id": "CVE-2021-38419",
  "lastModified": "2024-11-21T06:17:03.123",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.557",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-38409

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un acceso de puntero no inicializado, que puede permitir a un atacante leer o escribir en ubicaciones de memoria no esperadas, conllevando a una denegaci\u00f3n de servicio"
    }
  ],
  "id": "CVE-2021-38409",
  "lastModified": "2024-11-21T06:17:01.630",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.383",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-38401

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un acceso de puntero no inicializado, que puede permitir a un atacante ejecutar c\u00f3digo arbitrario y causar un bloqueo de la aplicaci\u00f3n"
    }
  ],
  "id": "CVE-2021-38401",
  "lastModified": "2024-11-21T06:17:00.403",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.320",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-822"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-38413

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria, que puede permitir a un atacante una ejecuci\u00f3n de c\u00f3digo"
    }
  ],
  "id": "CVE-2021-38413",
  "lastModified": "2024-11-21T06:17:02.293",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.440",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-38421

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a una lectura fuera de l\u00edmites, lo que puede permitir a un atacante leer informaci\u00f3n confidencial de otras ubicaciones de memoria o causar un bloqueo"
    }
  ],
  "id": "CVE-2021-38421",
  "lastModified": "2024-11-21T06:17:03.430",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.613",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-38415

Vulnerability from fkie_nvd - Published: 2021-12-20 21:15 - Updated: 2024-11-21 06:17
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "BDE5CC23-7376-4E69-988E-42719159E52C",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914",
              "versionEndExcluding": "4.0.12.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria cuando analizan un archivo de proyecto especialmente dise\u00f1ado, que puede permitir a un atacante ejecutar c\u00f3digo arbitrario"
    }
  ],
  "id": "CVE-2021-38415",
  "lastModified": "2024-11-21T06:17:02.447",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-20T21:15:08.500",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-22653

Vulnerability from fkie_nvd - Published: 2021-01-27 20:15 - Updated: 2024-11-21 05:50
Summary
Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de escritura fuera de l\u00edmites en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22653",
  "lastModified": "2024-11-21T05:50:24.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.317",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-22641

Vulnerability from fkie_nvd - Published: 2021-01-27 20:15 - Updated: 2024-11-21 05:50
Summary
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado un problema de desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22641",
  "lastModified": "2024-11-21T05:50:22.220",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.207",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-099/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-22655

Vulnerability from fkie_nvd - Published: 2021-01-27 20:15 - Updated: 2024-11-21 05:50
Summary
Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
References
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de lectura fuera de l\u00edmites en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22655",
  "lastModified": "2024-11-21T05:50:24.890",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:13.397",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-22637

Vulnerability from fkie_nvd - Published: 2021-01-27 20:15 - Updated: 2024-11-21 05:50
Summary
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se han identificado m\u00faltiples problemas de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22637",
  "lastModified": "2024-11-21T05:50:21.713",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:12.770",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-22639

Vulnerability from fkie_nvd - Published: 2021-01-27 20:15 - Updated: 2024-11-21 05:50
Summary
An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Impacted products
Vendor Product Version
fujielectric v-server *
fujielectric v-simulator *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "3D8B4395-7ADA-4752-9DFF-B83E054596E4",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
              "matchCriteriaId": "B5EB143F-D650-45F2-9948-B1C2246E56A0",
              "versionEndExcluding": "4.0.10.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado un problema de puntero no inicializado en la manera en que la aplicaci\u00f3n procesa archivos de proyecto, permitiendo a un atacante dise\u00f1ar un archivo de proyecto especial que puede permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el Tellus Lite V-Simulator y V-Server Lite (versiones anteriores a 4.0.10.0)"
    }
  ],
  "id": "CVE-2021-22639",
  "lastModified": "2024-11-21T05:50:21.947",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-27T20:15:12.847",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-098/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-38419 (GCVE-0-2021-38419)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator out of bounds write
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.
CWE
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:50",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38419",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38419",
    "datePublished": "2021-12-20T20:08:50",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.450Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38413 (GCVE-0-2021-38413)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator stack based buffer overflow
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.252Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:49",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38413",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38413",
    "datePublished": "2021-12-20T20:08:49",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.252Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38415 (GCVE-0-2021-38415)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator heap based buffer overflow
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38415",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122 Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38415",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38421 (GCVE-0-2021-38421)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator out of bounds read
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.
CWE
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds read",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38421",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds read"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125 Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38421",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.159Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38401 (GCVE-0-2021-38401)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.
CWE
  • CWE-822 - - Untrusted pointer dereference
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.513Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 - Untrusted pointer dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:47",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38401",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822 - Untrusted pointer dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38401",
    "datePublished": "2021-12-20T20:08:47",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.513Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38409 (GCVE-0-2021-38409)

Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator uninitialized pointer
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.
CWE
  • CWE-824 - Access of Uninitialized Pointer
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.652Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:46",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38409",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824 Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38409",
    "datePublished": "2021-12-20T20:08:46",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.652Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22637 (GCVE-0-2021-22637)

Vulnerability from cvelistv5 – Published: 2021-01-27 19:09 – Updated: 2024-08-03 18:44
VLAI?
Summary
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Affected: Versions prior to 4.0.10.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:44:14.149Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T07:06:36",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22637",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22637",
    "datePublished": "2021-01-27T19:09:49",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:44:14.149Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38419 (GCVE-0-2021-38419)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator out of bounds write
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution.
CWE
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:50",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38419",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38419",
    "datePublished": "2021-12-20T20:08:50",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.450Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38413 (GCVE-0-2021-38413)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator stack based buffer overflow
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.252Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:49",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38413",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38413",
    "datePublished": "2021-12-20T20:08:49",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.252Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38415 (GCVE-0-2021-38415)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator heap based buffer overflow
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38415",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122 Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38415",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38421 (GCVE-0-2021-38421)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator out of bounds read
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash.
CWE
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:48",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator out of bounds read",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38421",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds read"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125 Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38421",
    "datePublished": "2021-12-20T20:08:48",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.159Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38401 (GCVE-0-2021-38401)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.
CWE
  • CWE-822 - - Untrusted pointer dereference
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.513Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 - Untrusted pointer dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:47",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38401",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822 - Untrusted pointer dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38401",
    "datePublished": "2021-12-20T20:08:47",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.513Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38409 (GCVE-0-2021-38409)

Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37
VLAI?
Title
Fuji Electric Tellus Lite V-Simulator uninitialized pointer
Summary
Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service.
CWE
  • CWE-824 - Access of Uninitialized Pointer
Assigner
References
Impacted products
Vendor Product Version
Fuji Electric V-Server Lite Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
    Fuji Electric Tellus Lite V-Simulator Affected: unspecified , < 4.0.12.0 (custom)
Create a notification for this product.
Credits
kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:37:16.652Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:46",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38409",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824 Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38409",
    "datePublished": "2021-12-20T20:08:46",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:37:16.652Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22637 (GCVE-0-2021-22637)

Vulnerability from nvd – Published: 2021-01-27 19:09 – Updated: 2024-08-03 18:44
VLAI?
Summary
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
Impacted products
Vendor Product Version
n/a Tellus Lite V-Simulator and V-Server Lite Affected: Versions prior to 4.0.10.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:44:14.149Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tellus Lite V-Simulator and V-Server Lite",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.0.10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-29T07:06:36",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22637",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tellus Lite V-Simulator and V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions prior to 4.0.10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-097/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22637",
    "datePublished": "2021-01-27T19:09:49",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:44:14.149Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}