Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    5 vulnerabilities by se

    VAR-202005-0051

    Vulnerability from variot - Updated: 2023-12-18 12:27

    In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. Fazecast Provides jSerialComm To DLL There is a read vulnerability. jSerialComm Is Fazecast Provides platform-independent serial communication provided by Java The library. This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric EcoStruxure IT Gateway. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the handling of files within the Temp directory. The issue results from an incorrect assignment of privilege to a critical resource. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Schneider Electric EcoStruxure IT Gateway is a set of cloud-based data center management as a service (DMaaS) products of French Schneider Electric company. A code issue vulnerability exists in Fazecast jSerialComm 2.2.2 and earlier versions

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0051",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ecostruxure it gateway",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "1.6.2.14"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "1.5.0.66"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "1.6.0.39"
          },
          {
            "model": "jserialcomm",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "fazecast",
            "version": "2.2.2"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "1.5.2.28"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "schneider electric",
            "version": "1.7.0.64"
          },
          {
            "model": "jserialcomm",
            "scope": "eq",
            "trust": 0.9,
            "vendor": "fazecast",
            "version": "2.2.2"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "1.5.x \u7cfb"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "1.6.x \u7cfb"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schneider electric",
            "version": "1.7.x \u7cfb"
          },
          {
            "model": "ecostruxure it gateway",
            "scope": null,
            "trust": 0.7,
            "vendor": "schneider electric",
            "version": null
          },
          {
            "model": "ecostruxure it gateway",
            "scope": "eq",
            "trust": 0.1,
            "vendor": "se",
            "version": "1.7.0.64"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:fazecast:jserialcomm:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.5.2.28",
                    "versionStartIncluding": "1.5.0.66",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.6.2.14",
                    "versionStartIncluding": "1.6.0.39",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:1.7.0.64:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ryan Wincey (@rwincey) of Securifera",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-10626",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.4,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.4,
                "id": "VHN-163123",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:L/AC:M/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULMON",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.4,
                "id": "CVE-2020-10626",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "MEDIUM",
                "trust": 0.1,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "JPCERT/CC score",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004145",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-10626",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "NONE",
                "vectorString": "AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2020-10626",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "JPCERT/CC",
                "id": "JVNDB-2020-004145",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-10626",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202005-154",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-163123",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2020-10626",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. Fazecast Provides jSerialComm To DLL There is a read vulnerability. jSerialComm Is Fazecast Provides platform-independent serial communication provided by Java The library. This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric EcoStruxure IT Gateway. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the handling of files within the Temp directory. The issue results from an incorrect assignment of privilege to a critical resource. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Schneider Electric EcoStruxure IT Gateway is a set of cloud-based data center management as a service (DMaaS) products of French Schneider Electric company. A code issue vulnerability exists in Fazecast jSerialComm 2.2.2 and earlier versions",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          }
        ],
        "trust": 2.43
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-10626",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-20-588",
            "trust": 1.3
          },
          {
            "db": "JVN",
            "id": "JVNVU98082388",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-10377",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154",
            "trust": 0.7
          },
          {
            "db": "NSFOCUS",
            "id": "48504",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.1621",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123",
            "trust": 0.1
          },
          {
            "db": "PULSESECURE",
            "id": "SA201260",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "id": "VAR-202005-0051",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:27:30.624000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "jSerialComm",
            "trust": 1.6,
            "url": "https://github.com/fazecast/jserialcomm/releases"
          },
          {
            "title": "Schneider Electric has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://www.us-cert.gov/ics/advisories/icsa2012601"
          },
          {
            "title": "Fazecast jSerialComm Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=122410"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-427",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.3,
            "url": "https://www.us-cert.gov/ics/advisories/icsa2012601"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-10626"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/cert/jvnvu98082388"
          },
          {
            "trust": 0.6,
            "url": "http://www.nsfocus.net/vulndb/48504"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-10626"
          },
          {
            "trust": 0.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-20-588/"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.1621/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/427.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/181436"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-05-06T00:00:00",
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "date": "2020-05-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "date": "2020-05-14T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "date": "2020-05-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "date": "2020-05-14T16:15:12.530000",
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "date": "2020-05-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-05-06T00:00:00",
            "db": "ZDI",
            "id": "ZDI-20-588"
          },
          {
            "date": "2022-01-31T00:00:00",
            "db": "VULHUB",
            "id": "VHN-163123"
          },
          {
            "date": "2020-05-19T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-10626"
          },
          {
            "date": "2020-05-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          },
          {
            "date": "2022-01-31T19:33:27.307000",
            "db": "NVD",
            "id": "CVE-2020-10626"
          },
          {
            "date": "2022-03-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Fazecast Made  jSerialComm To DLL Read vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004145"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202005-154"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2023-37200 (GCVE-0-2023-37200)

    Vulnerability from nvd – Published: 2023-07-12 07:11 – Updated: 2024-11-07 14:07
    VLAI
    Summary
    A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric EcoStruxure OPC UA Server Expert Affected: Versions prior to SV2.01 SP2
    Create a notification for this product.
    Date Public
    2023-07-11 07:10
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:32.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-02.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37200",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:06:52.880283Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:07:40.931Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure OPC UA Server Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to SV2.01 SP2"
                }
              ]
            }
          ],
          "datePublic": "2023-07-11T07:10:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"
                }
              ],
              "value": "\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T07:11:30.005Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37200",
        "datePublished": "2023-07-12T07:11:30.005Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:07:40.931Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7496 (GCVE-0-2020-7496)

    Vulnerability from nvd – Published: 2020-06-16 19:13 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.
    Severity
    No CVSS data available.
    CWE
    • CWE-88 - Argument Injection or Modification
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) Affected: EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.584Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-88",
                  "description": "CWE-88: Argument Injection or Modification",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-06-16T19:13:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7496",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-88: Argument Injection or Modification"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7496",
        "datePublished": "2020-06-16T19:13:29.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.584Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37200 (GCVE-0-2023-37200)

    Vulnerability from cvelistv5 – Published: 2023-07-12 07:11 – Updated: 2024-11-07 14:07
    VLAI
    Summary
    A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric EcoStruxure OPC UA Server Expert Affected: Versions prior to SV2.01 SP2
    Create a notification for this product.
    Date Public
    2023-07-11 07:10
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:32.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-02.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37200",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:06:52.880283Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:07:40.931Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure OPC UA Server Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to SV2.01 SP2"
                }
              ]
            }
          ],
          "datePublic": "2023-07-11T07:10:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"
                }
              ],
              "value": "\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T07:11:30.005Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-02.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37200",
        "datePublished": "2023-07-12T07:11:30.005Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:07:40.931Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7496 (GCVE-0-2020-7496)

    Vulnerability from cvelistv5 – Published: 2020-06-16 19:13 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.
    Severity
    No CVSS data available.
    CWE
    • CWE-88 - Argument Injection or Modification
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) Affected: EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.584Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-88",
                  "description": "CWE-88: Argument Injection or Modification",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-06-16T19:13:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7496",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-88: Argument Injection or Modification"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-04"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7496",
        "datePublished": "2020-06-16T19:13:29.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.584Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }