CVE-2017-7907 (GCVE-0-2017-7907)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.
CWE
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 345 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
n/a Schneider Electric Wonderware Historian Client Affected: Schneider Electric Wonderware Historian Client
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:28.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "98254",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98254"
          },
          {
            "name": "1038542",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038542"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Wonderware Historian Client",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Wonderware Historian Client"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-07T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "98254",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98254"
        },
        {
          "name": "1038542",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038542"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7907",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Wonderware Historian Client",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Wonderware Historian Client"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-611"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "98254",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98254"
            },
            {
              "name": "1038542",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1038542"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
            },
            {
              "name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/",
              "refsource": "MISC",
              "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7907",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:28.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-7907",
      "date": "2026-10-26",
      "epss": "0.00388",
      "percentile": "0.32684"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:wonderware_historian_client:*:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "CDC90F0C-4ECA-48E4-B5A2-0DD5E7703DD9",
                  "versionEndIncluding": "2014_r2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network."
        },
        {
          "lang": "es",
          "value": "Se ha detectado un problema de configuraci\u00f3n del analizador XML incorrecto en el historial de clientes de Schneider Electric Wonderware Historian Client 2014 R2 SP1 y anterior. Un analizador XML incorrectamente restringido (con una restricci\u00f3n incorrecta de referencia de entidad externa XML o XXE) puede permitir que un intruso ingrese una entrada malintencionada a trav\u00e9s de la aplicaci\u00f3n que podr\u00eda causar una denegaci\u00f3n de servicio o revelar el contenido de un servidor o de una red conectada."
        }
      ],
      "id": "CVE-2017-7907",
      "lastModified": "2024-11-21T03:32:56.340",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 3.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.4,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.3,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2017-05-19T03:29:00.590",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98254"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "url": "http://www.securitytracker.com/id/1038542"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Mitigation",
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98254"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.securitytracker.com/id/1038542"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:wonderware_historian_client:*:sp1:*:*:*:*:*:*",
                    "matchCriteriaId": "CDC90F0C-4ECA-48E4-B5A2-0DD5E7703DD9",
                    "versionEndIncluding": "2014_r2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network."
          },
          {
            "lang": "es",
            "value": "Se ha detectado un problema de configuraci\u00f3n del analizador XML incorrecto en el historial de clientes de Schneider Electric Wonderware Historian Client 2014 R2 SP1 y anterior. Un analizador XML incorrectamente restringido (con una restricci\u00f3n incorrecta de referencia de entidad externa XML o XXE) puede permitir que un intruso ingrese una entrada malintencionada a trav\u00e9s de la aplicaci\u00f3n que podr\u00eda causar una denegaci\u00f3n de servicio o revelar el contenido de un servidor o de una red conectada."
          }
        ],
        "id": "CVE-2017-7907",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 3.4,
              "impactScore": 4.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.3,
              "impactScore": 5.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-05-19T03:29:00.590",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98254"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "http://www.securitytracker.com/id/1038542"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Mitigation",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98254"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.securitytracker.com/id/1038542"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mitigation",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.