CVE-2019-12682
Vulnerability from cvelistv5
Published
2019-10-02 19:06
Modified
2024-11-20 17:08
Summary
Cisco Firepower Management Center SQL Injection Vulnerabilities
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:24:39.163Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20191002 Cisco Firepower Management Center SQL Injection Vulnerabilities",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-12682",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-20T16:51:28.663068Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-20T17:08:12.886Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Firepower Management Center",
          "vendor": "Cisco",
          "versions": [
            {
              "lessThan": "n/a",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-10-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T19:06:41",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20191002 Cisco Firepower Management Center SQL Injection Vulnerabilities",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj"
        }
      ],
      "source": {
        "advisory": "cisco-sa-20191002-fmc-sql-inj",
        "defect": [
          [
            "CSCvh03939",
            "CSCvh03949",
            "CSCvh03955",
            "CSCvh77430",
            "CSCvh77441",
            "CSCvh77600",
            "CSCvh77847",
            "CSCvn69019"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Firepower Management Center SQL Injection Vulnerabilities",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2019-10-02T16:00:00-0700",
          "ID": "CVE-2019-12682",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Firepower Management Center SQL Injection Vulnerabilities"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Firepower Management Center",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "8.8",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20191002 Cisco Firepower Management Center SQL Injection Vulnerabilities",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-20191002-fmc-sql-inj",
          "defect": [
            [
              "CSCvh03939",
              "CSCvh03949",
              "CSCvh03955",
              "CSCvh77430",
              "CSCvh77441",
              "CSCvh77600",
              "CSCvh77847",
              "CSCvn69019"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2019-12682",
    "datePublished": "2019-10-02T19:06:41.886232Z",
    "dateReserved": "2019-06-04T00:00:00",
    "dateUpdated": "2024-11-20T17:08:12.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-12682\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-10-02T19:15:12.703\",\"lastModified\":\"2019-10-09T23:46:04.560\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device.\"},{\"lang\":\"es\",\"value\":\"M\u00faltiples vulnerabilidades en la interfaz de administraci\u00f3n basada en web del Software Cisco Firepower Management Center (FMC), podr\u00edan permitir a un atacante remoto autenticado ejecutar inyecciones SQL arbitrarias sobre un dispositivo afectado. Estas vulnerabilidades se presentan debido a una comprobaci\u00f3n de entrada inapropiada. Un atacante podr\u00eda explotar estas vulnerabilidades mediante el env\u00edo de consultas SQL creadas a un dispositivo afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar informaci\u00f3n que no est\u00e1 autorizado de ver, llevar a cabo cambios en el sistema que no est\u00e1 autorizado a realizar y ejecutar comandos dentro del sistema operativo subyacente que pueden afectar la disponibilidad del dispositivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":9.0},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99479490-9BB9-40BD-B4FB-A23D81E48631\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.