Action not permitted
Modal body text goes here.
CVE-2019-1810
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ykramarz@cisco.com | http://www.securityfocus.com/bid/108431 | Broken Link, Third Party Advisory, VDB Entry | |
ykramarz@cisco.com | https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv | Vendor Advisory |
▼ | Vendor | Product |
---|---|---|
Cisco | Cisco NX-OS Software |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T18:28:42.870Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20190515 Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "name": "108431", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108431" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Cisco NX-OS Software", "vendor": "Cisco", "versions": [ { "lessThan": "8.3(1)", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2019-05-15T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-347", "description": "CWE-347", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-05-23T09:06:09", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20190515 Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "name": "108431", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108431" } ], "source": { "advisory": "cisco-sa-20190515-nxos-sisv", "defect": [ [ "CSCvj14078" ] ], "discovery": "INTERNAL" }, "title": "Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-05-15T16:00:00-0700", "ID": "CVE-2019-1810", "STATE": "PUBLIC", "TITLE": "Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco NX-OS Software", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "8.3(1)" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "6.7", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-347" } ] } ] }, "references": { "reference_data": [ { "name": "20190515 Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "name": "108431", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108431" } ] }, "source": { "advisory": "cisco-sa-20190515-nxos-sisv", "defect": [ [ "CSCvj14078" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2019-1810", "datePublished": "2019-05-15T22:15:16.874528Z", "dateReserved": "2018-12-06T00:00:00", "dateUpdated": "2024-09-16T20:43:08.057Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-1810\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-05-15T23:29:01.153\",\"lastModified\":\"2023-03-24T17:46:33.507\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la funci\u00f3n Image Signature Verification utilizada en un comando CLI de NX-OS en los switches de las series Nexus 3000 y 9000 de Cisco podr\u00eda permitir a un atacante local autenticado con credenciales de administrador para instalar una imagen de programa malicioso en un dispositivo afectado. La vulnerabilidad se debe a que las firmas digitales del programa no se verifican correctamente durante la ejecuci\u00f3n del comando CLI. Un atacante podr\u00eda aprovechar esta vulnerabilidad para instalar una imagen de programa sin firmar en un dispositivo afectado. Nota: Si el dispositivo no ha sido parchado para la vulnerabilidad descrita anteriormente en el Aviso de seguridad de Cisco cisco-sa-20190306-nxos-sig-verif, un ataque exitoso podr\u00eda permitir al atacante iniciar una imagen de programa malicioso.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-347\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-347\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.1\\\\(2\\\\)i3\\\\(4\\\\)\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(5\\\\)\",\"matchCriteriaId\":\"210189FB-C22C-4257-90F8-15A4423F7BF9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i7\\\\(5a\\\\)\",\"versionEndExcluding\":\"9.2\\\\(2\\\\)\",\"matchCriteriaId\":\"59A1E5DE-BF89-49F3-87C0-0C2A51F28CFA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:n3k-c3164q:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D37D6E65-9F11-4C3C-857B-8509B276467A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i3\\\\(1\\\\)\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(1\\\\)\",\"matchCriteriaId\":\"CAEE89CF-815F-4A7B-B17B-9125AA04A033\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i7\\\\(2\\\\)\",\"versionEndExcluding\":\"9.2\\\\(1\\\\)\",\"matchCriteriaId\":\"CF2CCA0F-9A2E-4E5A-8A62-5F8F7ABFC9BD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:n3k-c3232c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F7916925-6E0A-41DB-B902-7028EB579013\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i4\\\\(1\\\\)\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(5\\\\)\",\"matchCriteriaId\":\"BB455C80-FB82-4AAF-A63E-A3E23E19E73B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i7\\\\(5a\\\\)\",\"versionEndExcluding\":\"9.2\\\\(2\\\\)\",\"matchCriteriaId\":\"59A1E5DE-BF89-49F3-87C0-0C2A51F28CFA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:n9k-c92304qc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"876304F4-4CE5-45B8-ADF5-2523319D05BB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i4\\\\(2\\\\)\",\"versionEndExcluding\":\"7.0\\\\(3\\\\)i7\\\\(5\\\\)\",\"matchCriteriaId\":\"8EF1BA94-CF4C-4615-9514-161890C3E8CC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\\\\(3\\\\)i7\\\\(5a\\\\)\",\"versionEndExcluding\":\"9.2\\\\(2\\\\)\",\"matchCriteriaId\":\"59A1E5DE-BF89-49F3-87C0-0C2A51F28CFA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:n9k-c9232c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A9C0219-7EDC-40FD-A66B-24A92993F692\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108431\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ghsa-3jwq-498g-6473
Vulnerability from github
A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image.
{ "affected": [], "aliases": [ "CVE-2019-1810" ], "database_specific": { "cwe_ids": [ "CWE-347" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-05-15T23:29:00Z", "severity": "MODERATE" }, "details": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image.", "id": "GHSA-3jwq-498g-6473", "modified": "2023-03-24T18:30:22Z", "published": "2022-05-24T16:45:56Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-1810" }, { "type": "WEB", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/108431" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
cisco-sa-20190515-nxos-sisv
Vulnerability from csaf_cisco
Notes
{ "document": { "acknowledgments": [ { "summary": "This vulnerability was found during internal security testing." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "notes": [ { "category": "summary", "text": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device.\r\n\r\nThe vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device.\r\n\r\nNote: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif [\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif\"], a successful exploit could allow the attacker to boot a malicious software image.\r\n\r\nCisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.\r\n\r\nThis advisory is available at the following link:\r\nhttps://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv [\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv\"]", "title": "Summary" }, { "category": "general", "text": "This vulnerability affects the following Cisco products if they are running a vulnerable release of Cisco NX-OS Software:\r\n\r\nNexus 3000 Series Switches with the following product IDs (PIDs):\r\n\r\nN3K-C3164Q\r\nN3K-C3232C\r\n\r\nNexus 9000 Series Switches in standalone NX-OS mode with the following PIDs:\r\nN9K-C92304QC\r\nN9K-C9232C\r\n\r\n\r\nNote: This vulnerability affects a limited number of products; only the preceding PIDs are affected by this vulnerability.\r\n\r\nFor information about which Cisco NX-OS Software releases are vulnerable, see the Fixed Software [\"https://tvce.cisco.com/security/AIMS/SecurityPublicationDetail.aspx?Mode=Edit\u0026ID=71204\u0026Version=1\u0026Revision=8#fs\"] section of this advisory.\r\n Determining the Cisco NX-OS Product ID\r\n To check the PID, administrators can use the show inventory command in the device CLI. The following example shows the output of the command for a device that has the PID N3K-C3232C:\r\n\r\n\r\n switch# show inventory\r\n NAME: \"Chassis\", DESCR: \"Nexus3000 C3232C Chassis\" PID: N3K-C3232C , VID: V02 , SN: FOC20291JA0 NAME: \"Slot 1\", DESCR: \"32x40/100G QSFP28 2x10G SFP+ Ethernet Module\" PID: N3K-C3232C , VID: V02 , SN: FOC20291JA0 NAME: \"Power Supply 1\", DESCR: \"Nexus3000 C3232C Chassis Power Supply\" PID: NXA-PAC-650W-PI , VID: V01 , SN: LIT20362Z6G", "title": "Vulnerable Products" }, { "category": "general", "text": "Only products listed in the Vulnerable Products [\"#vp\"] section of this advisory are known to be affected by this vulnerability.\r\n\r\nCisco has confirmed that this vulnerability does not affect the following Cisco products:\r\n\r\n Firepower 2100 Series\r\n Firepower 4100 Series\r\n Firepower 9300 Security Appliances\r\n MDS 9000 Series Multilayer Switches\r\n Nexus 1000V Switch for Microsoft Hyper-V\r\n Nexus 1000V Switch for VMware vSphere\r\n Nexus 3500 Platform Switches\r\n Nexus 3600 Platform Switches\r\n Nexus 5500 Platform Switches\r\n Nexus 5600 Platform Switches\r\n Nexus 6000 Series Switches\r\n Nexus 7000 Series Switches\r\n Nexus 7700 Series Switches\r\n Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode\r\n Nexus 9500 R-Series Switching Platform\r\n UCS 6200 Series Fabric Interconnects\r\n UCS 6300 Series Fabric Interconnects\r\n UCS 6400 Series Fabric Interconnects", "title": "Products Confirmed Not Vulnerable" }, { "category": "general", "text": "There are no workarounds that address this vulnerability.", "title": "Workarounds" }, { "category": "general", "text": "Cisco has released free software updates that address the vulnerability described in this advisory. Customers may only install and expect support for software versions and feature sets for which they have purchased a license. By installing, downloading, accessing, or otherwise using such software upgrades, customers agree to follow the terms of the Cisco software license: https://www.cisco.com/c/en/us/products/end-user-license-agreement.html [\"https://www.cisco.com/c/en/us/products/end-user-license-agreement.html\"]\r\n\r\nAdditionally, customers may only download software for which they have a valid license, procured from Cisco directly, or through a Cisco authorized reseller or partner. In most cases this will be a maintenance upgrade to software that was previously purchased. Free security software updates do not entitle customers to a new software license, additional software feature sets, or major revision upgrades.\r\n\r\nWhen considering software upgrades, customers are advised to regularly consult the advisories for Cisco products, which are available from the Cisco Security Advisories and Alerts page [\"https://www.cisco.com/go/psirt\"], to determine exposure and a complete upgrade solution.\r\n\r\nIn all cases, customers should ensure that the devices to be upgraded contain sufficient memory and confirm that current hardware and software configurations will continue to be supported properly by the new release. If the information is not clear, customers are advised to contact the Cisco Technical Assistance Center (TAC) or their contracted maintenance providers.\r\n Customers Without Service Contracts\r\nCustomers who purchase directly from Cisco but do not hold a Cisco service contract and customers who make purchases through third-party vendors but are unsuccessful in obtaining fixed software through their point of sale should obtain upgrades by contacting the Cisco TAC: https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html [\"https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html\"]\r\n\r\nCustomers should have the product serial number available and be prepared to provide the URL of this advisory as evidence of entitlement to a free upgrade.\r\n Fixed Releases\r\nCustomers are advised to upgrade to an appropriate release [\"https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html#fixes\"] as indicated in the following table. In the table, the left column lists the affected PIDs. The first affected Cisco NX-OS Software releases for each PID are in the center column. The right column indicates the first release that includes the fix for this vulnerability.\r\n\r\n Note: A complete fix for this vulnerability requires that a proper BIOS version is installed. Customers who are running a vulnerable PID listed in the following table may not have upgraded the BIOS when the software was installed even if they are running a fixed software release. Customers are advised to confirm that the BIOS is running a fixed BIOS version (first fixed or later) as described in the previously disclosed Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif [\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif\"].\r\n\r\nNexus 3000 Series Switches and Nexus 9000 Series Switches in Standalone NX-OS Mode: CSCvj14078 [\"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj14078 \"]\r\n Affected Product ID First Affected Release for This Vulnerability First Fixed Releases for This Vulnerability N3K-C3164Q 6.1(2)I3(4) 7.0(3)I7(5), 9.2(2) N3K-C3232C 7.0(3)I3(1) 7.0(3)I7(1), 9.2(1) N9K-C92304QC 7.0(3)I4(1) 7.0(3)I7(5), 9.2(2) N9K-C9232C 7.0(3)I4(2) 7.0(3)I7(5), 9.2(2)\r\nAdditional Resources\r\nFor help determining the best Cisco NX-OS Software release for a Cisco Nexus Switch, administrators can refer to the following Recommended Releases documents. If a security advisory recommends a later release, Cisco recommends following the advisory guidance.\r\n\r\n\r\nCisco MDS Series Switches [\"https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/b_MDS_NX-OS_Recommended_Releases.html\"]\r\nCisco Nexus 1000V for VMware Switch [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/recommended_releases/b_Cisco_N1KV_VMware_MinRecommendedReleases.html\"]\r\nCisco Nexus 3000 Series and 3500 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus3000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_3000_Series_Switches.html\"]\r\nCisco Nexus 5000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/release/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 5500 Platform Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5500/sw/release/recommended_releases/n5500_recommended_nx-os_releases.html\"]\r\nCisco Nexus 6000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus6000/sw/release/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 7000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html\"]\r\nCisco Nexus 9000 Series Switches [\"http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_9000_Series_Switches.html\"]\r\nCisco Nexus 9000 Series ACI-Mode Switches [\"https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/recommended-release/b_Recommended_Cisco_ACI_Releases.html\"]\r\n For help determining the best Cisco NX-OS Software release for Cisco UCS, refer to the Recommended Releases documents in the release notes for the device.", "title": "Fixed Software" }, { "category": "general", "text": "To learn about Cisco security vulnerability disclosure policies and publications, see the Security Vulnerability Policy [\"https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html\"]. This document also contains instructions for obtaining fixed software and receiving security vulnerability information from Cisco.", "title": "Vulnerability Policy" }, { "category": "general", "text": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.", "title": "Exploitation and Public Announcements" }, { "category": "general", "text": "This vulnerability was found during internal security testing.", "title": "Source" }, { "category": "legal_disclaimer", "text": "THIS DOCUMENT IS PROVIDED ON AN \"AS IS\" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. YOUR USE OF THE INFORMATION ON THE DOCUMENT OR MATERIALS LINKED FROM THE DOCUMENT IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS DOCUMENT AT ANY TIME.\r\n\r\nA standalone copy or paraphrase of the text of this document that omits the distribution URL is an uncontrolled copy and may lack important information or contain factual errors. The information in this document is intended for end users of Cisco products.", "title": "Legal Disclaimer" } ], "publisher": { "category": "vendor", "contact_details": "Emergency Support:\r\n+1 877 228 7302 (toll-free within North America)\r\n+1 408 525 6532 (International direct-dial)\r\nNon-emergency Support:\r\nEmail: psirt@cisco.com\r\nSupport requests that are received via e-mail are typically acknowledged within 48 hours.", "issuing_authority": "Cisco product security incident response is the responsibility of the Cisco Product Security Incident Response Team (PSIRT). The Cisco PSIRT is a dedicated, global team that manages the receipt, investigation, and public reporting of security vulnerability information that is related to Cisco products and networks. The on-call Cisco PSIRT works 24x7 with Cisco customers, independent security researchers, consultants, industry organizations, and other vendors to identify possible security issues with Cisco products and networks.\r\nMore information can be found in Cisco Security Vulnerability Policy available at https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html", "name": "Cisco", "namespace": "https://wwww.cisco.com" }, "references": [ { "category": "self", "summary": "Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "category": "external", "summary": "Cisco Security Vulnerability Policy", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html" }, { "category": "external", "summary": "cisco-sa-20190306-nxos-sig-verif", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif" }, { "category": "external", "summary": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "category": "external", "summary": "Fixed Software", "url": "https://tvce.cisco.com/security/AIMS/SecurityPublicationDetail.aspx?Mode=Edit\u0026amp;ID=71204\u0026amp;Version=1\u0026amp;Revision=8#fs" }, { "category": "external", "summary": "https://www.cisco.com/c/en/us/products/end-user-license-agreement.html", "url": "https://www.cisco.com/c/en/us/products/end-user-license-agreement.html" }, { "category": "external", "summary": "Cisco Security Advisories and Alerts page", "url": "https://www.cisco.com/go/psirt" }, { "category": "external", "summary": "https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html", "url": "https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html" }, { "category": "external", "summary": "upgrade to an appropriate release", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html#fixes" }, { "category": "external", "summary": "cisco-sa-20190306-nxos-sig-verif", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-sig-verif" }, { "category": "external", "summary": "CSCvj14078", "url": "https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvj14078" }, { "category": "external", "summary": "Cisco MDS Series Switches", "url": "https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/b_MDS_NX-OS_Recommended_Releases.html" }, { "category": "external", "summary": "Cisco Nexus 1000V for VMware Switch", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/recommended_releases/b_Cisco_N1KV_VMware_MinRecommendedReleases.html" }, { "category": "external", "summary": "Cisco Nexus 3000 Series and 3500 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus3000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_3000_Series_Switches.html" }, { "category": "external", "summary": "Cisco Nexus 5000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/release/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 5500 Platform Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5500/sw/release/recommended_releases/n5500_recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 6000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus6000/sw/release/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 7000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html" }, { "category": "external", "summary": "Cisco Nexus 9000 Series Switches", "url": "http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/recommended_release/b_Minimum_and_Recommended_Cisco_NX-OS_Releases_for_Cisco_Nexus_9000_Series_Switches.html" }, { "category": "external", "summary": "Cisco Nexus 9000 Series ACI-Mode Switches", "url": "https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/recommended-release/b_Recommended_Cisco_ACI_Releases.html" }, { "category": "external", "summary": "Security Vulnerability Policy", "url": "https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html" } ], "title": "Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "tracking": { "current_release_date": "2019-05-15T16:00:00+00:00", "generator": { "date": "2022-09-03T02:58:53+00:00", "engine": { "name": "TVCE" } }, "id": "cisco-sa-20190515-nxos-sisv", "initial_release_date": "2019-05-15T16:00:00+00:00", "revision_history": [ { "date": "2019-05-14T20:39:44+00:00", "number": "1.0.0", "summary": "Initial public release." } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "branches": [ { "category": "service_pack", "name": "6.1(1)", "product": { "name": "6.1(1)", "product_id": "CSAFPID-191457" } }, { "category": "service_pack", "name": "6.1(2)", "product": { "name": "6.1(2)", "product_id": "CSAFPID-191458" } }, { "category": "service_pack", "name": "6.1(3)", "product": { "name": "6.1(3)", "product_id": "CSAFPID-191459" } }, { "category": "service_pack", "name": "6.1(4)", "product": { "name": "6.1(4)", "product_id": "CSAFPID-196607" } }, { "category": "service_pack", "name": "6.1(4a)", "product": { "name": "6.1(4a)", "product_id": "CSAFPID-196608" } }, { "category": "service_pack", "name": "6.1(5)", "product": { "name": "6.1(5)", "product_id": "CSAFPID-212033" } }, { "category": "service_pack", "name": "6.1(3)S5", "product": { "name": "6.1(3)S5", "product_id": "CSAFPID-225656" } }, { "category": "service_pack", "name": "6.1(3)S6", "product": { "name": "6.1(3)S6", "product_id": "CSAFPID-225657" } }, { "category": "service_pack", "name": "6.1(5a)", "product": { "name": "6.1(5a)", "product_id": "CSAFPID-239433" } } ], "category": "product_version", "name": "6.1" }, { "branches": [ { "category": "service_pack", "name": "6.1(2)I1(3)", "product": { "name": "6.1(2)I1(3)", "product_id": "CSAFPID-239450" } }, { "category": "service_pack", "name": "6.1(2)I1(1)", "product": { "name": "6.1(2)I1(1)", "product_id": "CSAFPID-240152" } }, { "category": "service_pack", "name": "6.1(2)I1(2)", "product": { "name": "6.1(2)I1(2)", "product_id": "CSAFPID-240153" } } ], "category": "product_version", "name": "6.1(2)I1" }, { "branches": [ { "category": "service_pack", "name": "6.1(2)I2(1)", "product": { "name": "6.1(2)I2(1)", "product_id": "CSAFPID-201604" } }, { "category": "service_pack", "name": "6.1(2)I2(2)", "product": { "name": "6.1(2)I2(2)", "product_id": "CSAFPID-201605" } }, { "category": "service_pack", "name": "6.1(2)I2(2a)", "product": { "name": "6.1(2)I2(2a)", "product_id": "CSAFPID-201606" } }, { "category": "service_pack", "name": "6.1(2)I2(3)", "product": { "name": "6.1(2)I2(3)", "product_id": "CSAFPID-201607" } }, { "category": "service_pack", "name": "6.1(2)I2(2b)", "product": { "name": "6.1(2)I2(2b)", "product_id": "CSAFPID-202737" } } ], "category": "product_version", "name": "6.1(2)I2" }, { "branches": [ { "category": "service_pack", "name": "6.1(2)I3(1)", "product": { "name": "6.1(2)I3(1)", "product_id": "CSAFPID-205091" } }, { "category": "service_pack", "name": "6.1(2)I3(2)", "product": { "name": "6.1(2)I3(2)", "product_id": "CSAFPID-205092" } }, { "category": "service_pack", "name": "6.1(2)I3(3)", "product": { "name": "6.1(2)I3(3)", "product_id": "CSAFPID-205093" } }, { "category": "service_pack", "name": "6.1(2)I3(3.78)", "product": { "name": "6.1(2)I3(3.78)", "product_id": "CSAFPID-208867" } }, { "category": "service_pack", "name": "6.1(2)I3(4)", "product": { "name": "6.1(2)I3(4)", "product_id": "CSAFPID-210263" } }, { "category": "service_pack", "name": "6.1(2)I3(3a)", "product": { "name": "6.1(2)I3(3a)", "product_id": "CSAFPID-239451" } }, { "category": "service_pack", "name": "6.1(2)I3(4a)", "product": { "name": "6.1(2)I3(4a)", "product_id": "CSAFPID-239452" } }, { "category": "service_pack", "name": "6.1(2)I3(4b)", "product": { "name": "6.1(2)I3(4b)", "product_id": "CSAFPID-239453" } }, { "category": "service_pack", "name": "6.1(2)I3(4c)", "product": { "name": "6.1(2)I3(4c)", "product_id": "CSAFPID-239454" } }, { "category": "service_pack", "name": "6.1(2)I3(4d)", "product": { "name": "6.1(2)I3(4d)", "product_id": "CSAFPID-239455" } }, { "category": "service_pack", "name": "6.1(2)I3(4e)", "product": { "name": "6.1(2)I3(4e)", "product_id": "CSAFPID-239456" } }, { "category": "service_pack", "name": "6.1(2)I3(5)", "product": { "name": "6.1(2)I3(5)", "product_id": "CSAFPID-239457" } }, { "category": "service_pack", "name": "6.1(2)I3(5a)", "product": { "name": "6.1(2)I3(5a)", "product_id": "CSAFPID-239458" } }, { "category": "service_pack", "name": "6.1(2)I3(5b)", "product": { "name": "6.1(2)I3(5b)", "product_id": "CSAFPID-239459" } }, { "category": "service_pack", "name": "6.1(2)I3(3b)", "product": { "name": "6.1(2)I3(3b)", "product_id": "CSAFPID-240154" } } ], "category": "product_version", "name": "6.1(2)I3" }, { "branches": [ { "category": "service_pack", "name": "6.2(2)", "product": { "name": "6.2(2)", "product_id": "CSAFPID-196609" } }, { "category": "service_pack", "name": "6.2(2a)", "product": { "name": "6.2(2a)", "product_id": "CSAFPID-196610" } }, { "category": "service_pack", "name": "6.2(6)", "product": { "name": "6.2(6)", "product_id": "CSAFPID-202738" } }, { "category": "service_pack", "name": "6.2(6b)", "product": { "name": "6.2(6b)", "product_id": "CSAFPID-205071" } }, { "category": "service_pack", "name": "6.2(8)", "product": { "name": "6.2(8)", "product_id": "CSAFPID-205072" } }, { "category": "service_pack", "name": "6.2(8a)", "product": { "name": "6.2(8a)", "product_id": "CSAFPID-205073" } }, { "category": "service_pack", "name": "6.2(8b)", "product": { "name": "6.2(8b)", "product_id": "CSAFPID-205074" } }, { "category": "service_pack", "name": "6.2(10)", "product": { "name": "6.2(10)", "product_id": "CSAFPID-205075" } }, { "category": "service_pack", "name": "6.2(12)", "product": { "name": "6.2(12)", "product_id": "CSAFPID-208194" } }, { "category": "service_pack", "name": "6.2(18)", "product": { "name": "6.2(18)", "product_id": "CSAFPID-230441" } }, { "category": "service_pack", "name": "6.2(16)", "product": { "name": "6.2(16)", "product_id": "CSAFPID-230442" } }, { "category": "service_pack", "name": "6.2(14b)", "product": { "name": "6.2(14b)", "product_id": "CSAFPID-230443" } }, { "category": "service_pack", "name": "6.2(14)", "product": { "name": "6.2(14)", "product_id": "CSAFPID-230527" } }, { "category": "service_pack", "name": "6.2(14a)", "product": { "name": "6.2(14a)", "product_id": "CSAFPID-230528" } }, { "category": "service_pack", "name": "6.2(6a)", "product": { "name": "6.2(6a)", "product_id": "CSAFPID-239437" } }, { "category": "service_pack", "name": "6.2(20)", "product": { "name": "6.2(20)", "product_id": "CSAFPID-239445" } }, { "category": "service_pack", "name": "6.2(1)", "product": { "name": "6.2(1)", "product_id": "CSAFPID-239482" } }, { "category": "service_pack", "name": "6.2(3)", "product": { "name": "6.2(3)", "product_id": "CSAFPID-239483" } }, { "category": "service_pack", "name": "6.2(5)", "product": { "name": "6.2(5)", "product_id": "CSAFPID-239484" } }, { "category": "service_pack", "name": "6.2(5a)", "product": { "name": "6.2(5a)", "product_id": "CSAFPID-239485" } }, { "category": "service_pack", "name": "6.2(5b)", "product": { "name": "6.2(5b)", "product_id": "CSAFPID-239486" } }, { "category": "service_pack", "name": "6.2(7)", "product": { "name": "6.2(7)", "product_id": "CSAFPID-239487" } }, { "category": "service_pack", "name": "6.2(9)", "product": { "name": "6.2(9)", "product_id": "CSAFPID-239488" } }, { "category": "service_pack", "name": "6.2(9a)", "product": { "name": "6.2(9a)", "product_id": "CSAFPID-239489" } }, { "category": "service_pack", "name": "6.2(9b)", "product": { "name": "6.2(9b)", "product_id": "CSAFPID-239490" } }, { "category": "service_pack", "name": "6.2(9c)", "product": { "name": "6.2(9c)", "product_id": "CSAFPID-239491" } }, { "category": "service_pack", "name": "6.2(11)", "product": { "name": "6.2(11)", "product_id": "CSAFPID-239492" } }, { "category": "service_pack", "name": "6.2(11b)", "product": { "name": "6.2(11b)", "product_id": "CSAFPID-239493" } }, { "category": "service_pack", "name": "6.2(11c)", "product": { "name": "6.2(11c)", "product_id": "CSAFPID-239494" } }, { "category": "service_pack", "name": "6.2(11d)", "product": { "name": "6.2(11d)", "product_id": "CSAFPID-239495" } }, { "category": "service_pack", "name": "6.2(11e)", "product": { "name": "6.2(11e)", "product_id": "CSAFPID-239496" } }, { "category": "service_pack", "name": "6.2(13)", "product": { "name": "6.2(13)", "product_id": "CSAFPID-239497" } }, { "category": "service_pack", "name": "6.2(13a)", "product": { "name": "6.2(13a)", "product_id": "CSAFPID-239498" } }, { "category": "service_pack", "name": "6.2(13b)", "product": { "name": "6.2(13b)", "product_id": "CSAFPID-239499" } }, { "category": "service_pack", "name": "6.2(15)", "product": { "name": "6.2(15)", "product_id": "CSAFPID-239500" } }, { "category": "service_pack", "name": "6.2(17)", "product": { "name": "6.2(17)", "product_id": "CSAFPID-239501" } }, { "category": "service_pack", "name": "6.2(19)", "product": { "name": "6.2(19)", "product_id": "CSAFPID-239502" } }, { "category": "service_pack", "name": "6.2(21)", "product": { "name": "6.2(21)", "product_id": "CSAFPID-239503" } }, { "category": "service_pack", "name": "6.2(23)", "product": { "name": "6.2(23)", "product_id": "CSAFPID-239504" } }, { "category": "service_pack", "name": "6.2(20a)", "product": { "name": "6.2(20a)", "product_id": "CSAFPID-248858" } }, { "category": "service_pack", "name": "6.2(25)", "product": { "name": "6.2(25)", "product_id": "CSAFPID-256166" } } ], "category": "product_version", "name": "6.2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)", "product": { "name": "7.0(3)", "product_id": "CSAFPID-208195" } } ], "category": "product_version", "name": "7.0" }, { "branches": [ { "category": "service_pack", "name": "7.0(0)N1(1)", "product": { "name": "7.0(0)N1(1)", "product_id": "CSAFPID-201884" } } ], "category": "product_version", "name": "7.0(0)N1" }, { "branches": [ { "category": "service_pack", "name": "7.0(1)N1(1)", "product": { "name": "7.0(1)N1(1)", "product_id": "CSAFPID-201885" } }, { "category": "service_pack", "name": "7.0(1)N1(3)", "product": { "name": "7.0(1)N1(3)", "product_id": "CSAFPID-213631" } } ], "category": "product_version", "name": "7.0(1)N1" }, { "branches": [ { "category": "service_pack", "name": "7.0(2)I2(2c)", "product": { "name": "7.0(2)I2(2c)", "product_id": "CSAFPID-239460" } } ], "category": "product_version", "name": "7.0(2)I2" }, { "branches": [ { "category": "service_pack", "name": "7.0(2)N1(1)", "product": { "name": "7.0(2)N1(1)", "product_id": "CSAFPID-201886" } }, { "category": "service_pack", "name": "7.0(2)N1(1a)", "product": { "name": "7.0(2)N1(1a)", "product_id": "CSAFPID-230508" } } ], "category": "product_version", "name": "7.0(2)N1" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F1(1)", "product": { "name": "7.0(3)F1(1)", "product_id": "CSAFPID-239805" } } ], "category": "product_version", "name": "7.0(3)F1" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F2(1)", "product": { "name": "7.0(3)F2(1)", "product_id": "CSAFPID-239806" } }, { "category": "service_pack", "name": "7.0(3)F2(2)", "product": { "name": "7.0(3)F2(2)", "product_id": "CSAFPID-239807" } } ], "category": "product_version", "name": "7.0(3)F2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)F3(1)", "product": { "name": "7.0(3)F3(1)", "product_id": "CSAFPID-239632" } }, { "category": "service_pack", "name": "7.0(3)F3(2)", "product": { "name": "7.0(3)F3(2)", "product_id": "CSAFPID-239633" } }, { "category": "service_pack", "name": "7.0(3)F3(3)", "product": { "name": "7.0(3)F3(3)", "product_id": "CSAFPID-239634" } }, { "category": "service_pack", "name": "7.0(3)F3(3a)", "product": { "name": "7.0(3)F3(3a)", "product_id": "CSAFPID-239635" } }, { "category": "service_pack", "name": "7.0(3)F3(4)", "product": { "name": "7.0(3)F3(4)", "product_id": "CSAFPID-239636" } }, { "category": "service_pack", "name": "7.0(3)F3(3c)", "product": { "name": "7.0(3)F3(3c)", "product_id": "CSAFPID-248790" } }, { "category": "service_pack", "name": "7.0(3)F3(3b)", "product": { "name": "7.0(3)F3(3b)", "product_id": "CSAFPID-256141" } }, { "category": "service_pack", "name": "7.0(3)F3(5)", "product": { "name": "7.0(3)F3(5)", "product_id": "CSAFPID-256529" } } ], "category": "product_version", "name": "7.0(3)F3" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I1(1)", "product": { "name": "7.0(3)I1(1)", "product_id": "CSAFPID-208580" } }, { "category": "service_pack", "name": "7.0(3)I1(1a)", "product": { "name": "7.0(3)I1(1a)", "product_id": "CSAFPID-208581" } }, { "category": "service_pack", "name": "7.0(3)I1(1b)", "product": { "name": "7.0(3)I1(1b)", "product_id": "CSAFPID-208582" } }, { "category": "service_pack", "name": "7.0(3)I1(2)", "product": { "name": "7.0(3)I1(2)", "product_id": "CSAFPID-208583" } }, { "category": "service_pack", "name": "7.0(3)I1(3)", "product": { "name": "7.0(3)I1(3)", "product_id": "CSAFPID-220738" } }, { "category": "service_pack", "name": "7.0(3)I1(3a)", "product": { "name": "7.0(3)I1(3a)", "product_id": "CSAFPID-220739" } }, { "category": "service_pack", "name": "7.0(3)I1(3b)", "product": { "name": "7.0(3)I1(3b)", "product_id": "CSAFPID-220740" } } ], "category": "product_version", "name": "7.0(3)I1" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I2(2a)", "product": { "name": "7.0(3)I2(2a)", "product_id": "CSAFPID-220741" } }, { "category": "service_pack", "name": "7.0(3)I2(2b)", "product": { "name": "7.0(3)I2(2b)", "product_id": "CSAFPID-220742" } }, { "category": "service_pack", "name": "7.0(3)I2(2c)", "product": { "name": "7.0(3)I2(2c)", "product_id": "CSAFPID-220743" } }, { "category": "service_pack", "name": "7.0(3)I2(2d)", "product": { "name": "7.0(3)I2(2d)", "product_id": "CSAFPID-220744" } }, { "category": "service_pack", "name": "7.0(3)I2(2e)", "product": { "name": "7.0(3)I2(2e)", "product_id": "CSAFPID-220745" } }, { "category": "service_pack", "name": "7.0(3)I2(3)", "product": { "name": "7.0(3)I2(3)", "product_id": "CSAFPID-220746" } }, { "category": "service_pack", "name": "7.0(3)I2(4)", "product": { "name": "7.0(3)I2(4)", "product_id": "CSAFPID-220747" } }, { "category": "service_pack", "name": "7.0(3)I2(5)", "product": { "name": "7.0(3)I2(5)", "product_id": "CSAFPID-230554" } }, { "category": "service_pack", "name": "7.0(3)I2(1)", "product": { "name": "7.0(3)I2(1)", "product_id": "CSAFPID-230567" } }, { "category": "service_pack", "name": "7.0(3)I2(1a)", "product": { "name": "7.0(3)I2(1a)", "product_id": "CSAFPID-230568" } }, { "category": "service_pack", "name": "7.0(3)I2(2)", "product": { "name": "7.0(3)I2(2)", "product_id": "CSAFPID-230569" } } ], "category": "product_version", "name": "7.0(3)I2" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I3(1)", "product": { "name": "7.0(3)I3(1)", "product_id": "CSAFPID-220748" } } ], "category": "product_version", "name": "7.0(3)I3" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I4(1)", "product": { "name": "7.0(3)I4(1)", "product_id": "CSAFPID-220749" } }, { "category": "service_pack", "name": "7.0(3)I4(2)", "product": { "name": "7.0(3)I4(2)", "product_id": "CSAFPID-220750" } }, { "category": "service_pack", "name": "7.0(3)I4(3)", "product": { "name": "7.0(3)I4(3)", "product_id": "CSAFPID-220751" } }, { "category": "service_pack", "name": "7.0(3)I4(4)", "product": { "name": "7.0(3)I4(4)", "product_id": "CSAFPID-230530" } }, { "category": "service_pack", "name": "7.0(3)I4(5)", "product": { "name": "7.0(3)I4(5)", "product_id": "CSAFPID-230531" } }, { "category": "service_pack", "name": "7.0(3)I4(6)", "product": { "name": "7.0(3)I4(6)", "product_id": "CSAFPID-230532" } }, { "category": "service_pack", "name": "7.0(3)I4(7)", "product": { "name": "7.0(3)I4(7)", "product_id": "CSAFPID-230534" } }, { "category": "service_pack", "name": "7.0(3)I4(8)", "product": { "name": "7.0(3)I4(8)", "product_id": "CSAFPID-239472" } }, { "category": "service_pack", "name": "7.0(3)I4(8a)", "product": { "name": "7.0(3)I4(8a)", "product_id": "CSAFPID-256872" } }, { "category": "service_pack", "name": "7.0(3)I4(8b)", "product": { "name": "7.0(3)I4(8b)", "product_id": "CSAFPID-256873" } }, { "category": "service_pack", "name": "7.0(3)I4(8z)", "product": { "name": "7.0(3)I4(8z)", "product_id": "CSAFPID-256874" } }, { "category": "service_pack", "name": "7.0(3)I7(5a)", "product": { "name": "7.0(3)I7(5a)", "product_id": "CSAFPID-257394" } } ], "category": "product_version", "name": "7.0(3)I4" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I5(1)", "product": { "name": "7.0(3)I5(1)", "product_id": "CSAFPID-230535" } }, { "category": "service_pack", "name": "7.0(3)I5(2)", "product": { "name": "7.0(3)I5(2)", "product_id": "CSAFPID-230536" } } ], "category": "product_version", "name": "7.0(3)I5" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I6(1)", "product": { "name": "7.0(3)I6(1)", "product_id": "CSAFPID-230541" } }, { "category": "service_pack", "name": "7.0(3)I6(2)", "product": { "name": "7.0(3)I6(2)", "product_id": "CSAFPID-239476" } } ], "category": "product_version", "name": "7.0(3)I6" }, { "branches": [ { "category": "service_pack", "name": "7.0(3)I7(1)", "product": { "name": "7.0(3)I7(1)", "product_id": "CSAFPID-230542" } }, { "category": "service_pack", "name": "7.0(3)I7(2)", "product": { "name": "7.0(3)I7(2)", "product_id": "CSAFPID-239478" } }, { "category": "service_pack", "name": "7.0(3)I7(3)", "product": { "name": "7.0(3)I7(3)", "product_id": "CSAFPID-239479" } }, { "category": "service_pack", "name": "7.0(3)I7(4)", "product": { "name": "7.0(3)I7(4)", "product_id": "CSAFPID-248792" } }, { "category": "service_pack", "name": "7.0(3)I7(5a)", "product": { "name": "7.0(3)I7(5a)", "product_id": "CSAFPID-256875" } } ], "category": "product_version", "name": "7.0(3)I7" }, { "branches": [ { "category": "service_pack", "name": "9.2(1)", "product": { "name": "9.2(1)", "product_id": "CSAFPID-248793" } } ], "category": "product_version", "name": "9.2" } ], "category": "product_family", "name": "Cisco NX-OS Software" } ], "category": "vendor", "name": "Cisco" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-1810", "ids": [ { "system_name": "Cisco Bug ID", "text": "CSCvj14078" } ], "notes": [ { "category": "other", "text": "Complete.", "title": "Affected Product Comprehensiveness" } ], "product_status": { "known_affected": [ "CSAFPID-191457", "CSAFPID-191458", "CSAFPID-191459", "CSAFPID-196607", "CSAFPID-196608", "CSAFPID-196609", "CSAFPID-196610", "CSAFPID-201604", "CSAFPID-201605", "CSAFPID-201606", "CSAFPID-201607", "CSAFPID-201884", "CSAFPID-201885", "CSAFPID-201886", "CSAFPID-202737", "CSAFPID-202738", "CSAFPID-205071", "CSAFPID-205072", "CSAFPID-205073", "CSAFPID-205074", "CSAFPID-205075", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208194", "CSAFPID-208195", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-212033", "CSAFPID-213631", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-225656", "CSAFPID-225657", "CSAFPID-230441", "CSAFPID-230442", "CSAFPID-230443", "CSAFPID-230508", "CSAFPID-230527", "CSAFPID-230528", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-230568", "CSAFPID-230569", "CSAFPID-239433", "CSAFPID-239437", "CSAFPID-239445", "CSAFPID-239450", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239482", "CSAFPID-239483", "CSAFPID-239484", "CSAFPID-239485", "CSAFPID-239486", "CSAFPID-239487", "CSAFPID-239488", "CSAFPID-239489", "CSAFPID-239490", "CSAFPID-239491", "CSAFPID-239492", "CSAFPID-239493", "CSAFPID-239494", "CSAFPID-239495", "CSAFPID-239496", "CSAFPID-239497", "CSAFPID-239498", "CSAFPID-239499", "CSAFPID-239500", "CSAFPID-239501", "CSAFPID-239502", "CSAFPID-239503", "CSAFPID-239504", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-240152", "CSAFPID-240153", "CSAFPID-240154", "CSAFPID-248790", "CSAFPID-248792", "CSAFPID-248793", "CSAFPID-248858", "CSAFPID-256141", "CSAFPID-256166", "CSAFPID-256529", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874", "CSAFPID-256875", "CSAFPID-257394" ] }, "release_date": "2019-05-15T16:00:00+00:00", "remediations": [ { "category": "vendor_fix", "details": "Cisco has released software updates that address this vulnerability.", "product_ids": [ "CSAFPID-191457", "CSAFPID-191458", "CSAFPID-191459", "CSAFPID-196607", "CSAFPID-196608", "CSAFPID-196609", "CSAFPID-196610", "CSAFPID-201604", "CSAFPID-201605", "CSAFPID-201606", "CSAFPID-201607", "CSAFPID-201884", "CSAFPID-201885", "CSAFPID-201886", "CSAFPID-202737", "CSAFPID-202738", "CSAFPID-205071", "CSAFPID-205072", "CSAFPID-205073", "CSAFPID-205074", "CSAFPID-205075", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208194", "CSAFPID-208195", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-212033", "CSAFPID-213631", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-225656", "CSAFPID-225657", "CSAFPID-230441", "CSAFPID-230442", "CSAFPID-230443", "CSAFPID-230508", "CSAFPID-230527", "CSAFPID-230528", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-230568", "CSAFPID-230569", "CSAFPID-239433", "CSAFPID-239437", "CSAFPID-239445", "CSAFPID-239450", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239482", "CSAFPID-239483", "CSAFPID-239484", "CSAFPID-239485", "CSAFPID-239486", "CSAFPID-239487", "CSAFPID-239488", "CSAFPID-239489", "CSAFPID-239490", "CSAFPID-239491", "CSAFPID-239492", "CSAFPID-239493", "CSAFPID-239494", "CSAFPID-239495", "CSAFPID-239496", "CSAFPID-239497", "CSAFPID-239498", "CSAFPID-239499", "CSAFPID-239500", "CSAFPID-239501", "CSAFPID-239502", "CSAFPID-239503", "CSAFPID-239504", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-240152", "CSAFPID-240153", "CSAFPID-240154", "CSAFPID-248790", "CSAFPID-248792", "CSAFPID-248793", "CSAFPID-248858", "CSAFPID-256141", "CSAFPID-256166", "CSAFPID-256529", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874", "CSAFPID-256875", "CSAFPID-257394" ], "url": "https://software.cisco.com" } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-191457", "CSAFPID-191458", "CSAFPID-191459", "CSAFPID-196607", "CSAFPID-196608", "CSAFPID-196609", "CSAFPID-196610", "CSAFPID-201604", "CSAFPID-201605", "CSAFPID-201606", "CSAFPID-201607", "CSAFPID-201884", "CSAFPID-201885", "CSAFPID-201886", "CSAFPID-202737", "CSAFPID-202738", "CSAFPID-205071", "CSAFPID-205072", "CSAFPID-205073", "CSAFPID-205074", "CSAFPID-205075", "CSAFPID-205091", "CSAFPID-205092", "CSAFPID-205093", "CSAFPID-208194", "CSAFPID-208195", "CSAFPID-208580", "CSAFPID-208581", "CSAFPID-208582", "CSAFPID-208583", "CSAFPID-208867", "CSAFPID-210263", "CSAFPID-212033", "CSAFPID-213631", "CSAFPID-220738", "CSAFPID-220739", "CSAFPID-220740", "CSAFPID-220741", "CSAFPID-220742", "CSAFPID-220743", "CSAFPID-220744", "CSAFPID-220745", "CSAFPID-220746", "CSAFPID-220747", "CSAFPID-220748", "CSAFPID-220749", "CSAFPID-220750", "CSAFPID-220751", "CSAFPID-225656", "CSAFPID-225657", "CSAFPID-230441", "CSAFPID-230442", "CSAFPID-230443", "CSAFPID-230508", "CSAFPID-230527", "CSAFPID-230528", "CSAFPID-230530", "CSAFPID-230531", "CSAFPID-230532", "CSAFPID-230534", "CSAFPID-230535", "CSAFPID-230536", "CSAFPID-230541", "CSAFPID-230542", "CSAFPID-230554", "CSAFPID-230567", "CSAFPID-230568", "CSAFPID-230569", "CSAFPID-239433", "CSAFPID-239437", "CSAFPID-239445", "CSAFPID-239450", "CSAFPID-239451", "CSAFPID-239452", "CSAFPID-239453", "CSAFPID-239454", "CSAFPID-239455", "CSAFPID-239456", "CSAFPID-239457", "CSAFPID-239458", "CSAFPID-239459", "CSAFPID-239460", "CSAFPID-239472", "CSAFPID-239476", "CSAFPID-239478", "CSAFPID-239479", "CSAFPID-239482", "CSAFPID-239483", "CSAFPID-239484", "CSAFPID-239485", "CSAFPID-239486", "CSAFPID-239487", "CSAFPID-239488", "CSAFPID-239489", "CSAFPID-239490", "CSAFPID-239491", "CSAFPID-239492", "CSAFPID-239493", "CSAFPID-239494", "CSAFPID-239495", "CSAFPID-239496", "CSAFPID-239497", "CSAFPID-239498", "CSAFPID-239499", "CSAFPID-239500", "CSAFPID-239501", "CSAFPID-239502", "CSAFPID-239503", "CSAFPID-239504", "CSAFPID-239632", "CSAFPID-239633", "CSAFPID-239634", "CSAFPID-239635", "CSAFPID-239636", "CSAFPID-239805", "CSAFPID-239806", "CSAFPID-239807", "CSAFPID-240152", "CSAFPID-240153", "CSAFPID-240154", "CSAFPID-248790", "CSAFPID-248792", "CSAFPID-248793", "CSAFPID-248858", "CSAFPID-256141", "CSAFPID-256166", "CSAFPID-256529", "CSAFPID-256872", "CSAFPID-256873", "CSAFPID-256874", "CSAFPID-256875", "CSAFPID-257394" ] } ], "title": "Cisco Nexus 3000 Series and 9000 Series Switches in Standalone NX-OS Mode Software Image Signature Verification Vulnerability" } ] }
gsd-2019-1810
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-1810", "description": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image.", "id": "GSD-2019-1810" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-1810" ], "details": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image.", "id": "GSD-2019-1810", "modified": "2023-12-13T01:23:51.497788Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-05-15T16:00:00-0700", "ID": "CVE-2019-1810", "STATE": "PUBLIC", "TITLE": "Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco NX-OS Software", "version": { "version_data": [ { "affected": "\u003c", "version_value": "8.3(1)" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. " } ], "impact": { "cvss": { "baseScore": "6.7", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-347" } ] } ] }, "references": { "reference_data": [ { "name": "20190515 Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "name": "108431", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108431" } ] }, "source": { "advisory": "cisco-sa-20190515-nxos-sisv", "defect": [ [ "CSCvj14078" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "6.1\\(2\\)i3\\(4\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n3k-c3164q:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(1\\)", "versionStartIncluding": "7.0\\(3\\)i3\\(1\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(1\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(2\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n3k-c3232c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "7.0\\(3\\)i4\\(1\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n9k-c92304qc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "7.0\\(3\\)i4\\(2\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n9k-c9232c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2019-1810" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-347" } ] } ] }, "references": { "reference_data": [ { "name": "20190515 Cisco Nexus 3000 Series and 9000 Series Switches in NX-OS Mode CLI Command Software Image Signature Verification Vulnerability", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-sisv" }, { "name": "108431", "refsource": "BID", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/108431" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-03-24T17:46Z", "publishedDate": "2019-05-15T23:29Z" } } }
var-201905-0533
Vulnerability from variot
A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image. Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches are products of Cisco. The Cisco Nexus 3000 Series Switches is a 3000 Series switch. The Cisco Nexus 9000 Series Switches is a 9000 Series switch. Attackers can use fake data to attack. Successfully exploiting this issue may allow an attacker to perform unauthorized actions. This may lead to other attacks. This issue is being tracked by Cisco Bug ID CSCvj14078. The following products and versions are affected: Cisco N3K-C3164Q; N3K-C3232C; N9K-C92304QC; N9K-C9232C
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0533", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "6.1\\(2\\)i3\\(4\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i3\\(1\\)" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i7\\(1\\)" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "9.2\\(2\\)" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "9.2\\(1\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i7\\(2\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i4\\(1\\)" }, { "model": "nx-os", "scope": "lt", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i7\\(5\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i4\\(2\\)" }, { "model": "nx-os", "scope": "gte", "trust": 1.0, "vendor": "cisco", "version": "7.0\\(3\\)i7\\(5a\\)" }, { "model": "nx-os", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "nexus c3164q", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "3000" }, { "model": "nexus c3232c", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "3000" }, { "model": "nexus c92304qc", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "9000" }, { "model": "nexus c9232c", "scope": "eq", "trust": 0.6, "vendor": "cisco", "version": "9000" }, { "model": "nx-os 7.0 i7", "scope": null, "trust": 0.3, "vendor": "cisco", "version": null }, { "model": "nx-os", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "0" }, { "model": "nexus series switches", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "90000" }, { "model": "nexus series switches", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "30000" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "BID", "id": "108431" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "6.1\\(2\\)i3\\(4\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n3k-c3164q:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(1\\)", "versionStartIncluding": "7.0\\(3\\)i3\\(1\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(1\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(2\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n3k-c3232c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "7.0\\(3\\)i4\\(1\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n9k-c92304qc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0\\(3\\)i7\\(5\\)", "versionStartIncluding": "7.0\\(3\\)i4\\(2\\)", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "9.2\\(2\\)", "versionStartIncluding": "7.0\\(3\\)i7\\(5a\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n9k-c9232c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-1810" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco", "sources": [ { "db": "BID", "id": "108431" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ], "trust": 0.9 }, "cve": "CVE-2019-1810", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 4.6, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2019-1810", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CNVD-2019-29417", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "VHN-150412", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ykramarz@cisco.com", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-1810", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-1810", "trust": 1.8, "value": "MEDIUM" }, { "author": "ykramarz@cisco.com", "id": "CVE-2019-1810", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2019-29417", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201905-687", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-150412", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "VULHUB", "id": "VHN-150412" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in the Image Signature Verification feature used in an NX-OS CLI command in Cisco Nexus 3000 Series and 9000 Series Switches could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability exists because software digital signatures are not properly verified during CLI command execution. An attacker could exploit this vulnerability to install an unsigned software image on an affected device. Note: If the device has not been patched for the vulnerability previously disclosed in the Cisco Security Advisory cisco-sa-20190306-nxos-sig-verif, a successful exploit could allow the attacker to boot a malicious software image. Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches are products of Cisco. The Cisco Nexus 3000 Series Switches is a 3000 Series switch. The Cisco Nexus 9000 Series Switches is a 9000 Series switch. Attackers can use fake data to attack. \nSuccessfully exploiting this issue may allow an attacker to perform unauthorized actions. This may lead to other attacks. \nThis issue is being tracked by Cisco Bug ID CSCvj14078. The following products and versions are affected: Cisco N3K-C3164Q; N3K-C3232C; N9K-C92304QC; N9K-C9232C", "sources": [ { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "BID", "id": "108431" }, { "db": "VULHUB", "id": "VHN-150412" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-1810", "trust": 3.4 }, { "db": "BID", "id": "108431", "trust": 2.0 }, { "db": "JVNDB", "id": "JVNDB-2019-004591", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201905-687", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2019-29417", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1755", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-150412", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "VULHUB", "id": "VHN-150412" }, { "db": "BID", "id": "108431" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "id": "VAR-201905-0533", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "VULHUB", "id": "VHN-150412" } ], "trust": 1.235938135 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" } ] }, "last_update_date": "2023-12-18T14:05:09.558000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20190515-nxos-sisv", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190515-nxos-sisv" }, { "title": "Patch for Cisco Nexus 3000 Series and 9000 Series Switches Data Forgery Vulnerability Vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/177959" }, { "title": "Cisco Nexus 3000 Series and 9000 Series Switches Repair measures for data forgery problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=92811" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-347", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-150412" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.securityfocus.com/bid/108431" }, { "trust": 2.0, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190515-nxos-sisv" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-1810" }, { "trust": 0.9, "url": "http://www.cisco.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-1810" }, { "trust": 0.6, "url": "https://web.nvd.nist.gov//vuln/detail/cve-2019-1810" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/81102" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/cisco-nexus-multiple-vulnerabilities-via-signature-29341" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "VULHUB", "id": "VHN-150412" }, { "db": "BID", "id": "108431" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-29417" }, { "db": "VULHUB", "id": "VHN-150412" }, { "db": "BID", "id": "108431" }, { "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "db": "NVD", "id": "CVE-2019-1810" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-14T00:00:00", "db": "CNVD", "id": "CNVD-2019-29417" }, { "date": "2019-05-15T00:00:00", "db": "VULHUB", "id": "VHN-150412" }, { "date": "2019-05-15T00:00:00", "db": "BID", "id": "108431" }, { "date": "2019-06-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "date": "2019-05-15T23:29:01.153000", "db": "NVD", "id": "CVE-2019-1810" }, { "date": "2019-05-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-30T00:00:00", "db": "CNVD", "id": "CNVD-2019-29417" }, { "date": "2019-05-23T00:00:00", "db": "VULHUB", "id": "VHN-150412" }, { "date": "2019-05-15T00:00:00", "db": "BID", "id": "108431" }, { "date": "2019-06-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004591" }, { "date": "2023-03-24T17:46:33.507000", "db": "NVD", "id": "CVE-2019-1810" }, { "date": "2019-05-27T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-687" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "BID", "id": "108431" }, { "db": "CNNVD", "id": "CNNVD-201905-687" } ], "trust": 0.9 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Nexus 3000 and 9000 Series switch NX-OS CLI command Vulnerability in digital signature verification", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004591" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "data forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-687" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.