CVE-2019-5183 (GCVE-0-2019-5183)
Vulnerability from cvelistv5 – Published: 2020-01-25 17:59 – Updated: 2024-08-04 19:47
VLAI?
Summary
An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host.
Severity ?
No CVSS data available.
CWE
- type confusion
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:47:56.673Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AMD",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "AMD ATIDXX64.DLL (26.20.13031.10003, 26.20.13031.15006, 26.20.13031.18002) running on Radeon RX 550 / 550 Series VMware Workstation 15 (15.5.0 build-14665864) with Windows 10 x64 as guestVM"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "type confusion",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-25T17:59:18",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2019-5183",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AMD",
"version": {
"version_data": [
{
"version_value": "AMD ATIDXX64.DLL (26.20.13031.10003, 26.20.13031.15006, 26.20.13031.18002) running on Radeon RX 550 / 550 Series VMware Workstation 15 (15.5.0 build-14665864) with Windows 10 x64 as guestVM"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "type confusion"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2019-5183",
"datePublished": "2020-01-25T17:59:18",
"dateReserved": "2019-01-04T00:00:00",
"dateUpdated": "2024-08-04T19:47:56.673Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:amd:atidxx64:26.20.13031.10003:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EC82656D-2131-4934-9A1D-A51C78120B1E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:amd:atidxx64:26.20.13031.15006:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F5723683-8C9E-444E-A657-31BCF5F7E25C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:amd:atidxx64:26.20.13031.18002:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1F23D439-AB74-4CCD-BDC3-4980B78193E8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:a:vmware:workstation:15.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83DF9A19-ED8A-4914-96FA-D156CA9AFBC5\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de confusi\\u00f3n de tipos explotable en el controlador AMD ATIDXX64.DLL, versiones 26.20.13031.10003, 26.20.13031.15006 y 26.20.13031.18002. Un sombreador de p\\u00edxeles especialmente dise\\u00f1ado puede causar un problema de confusi\\u00f3n de tipos, conllevando a una potencial ejecuci\\u00f3n de c\\u00f3digo. Un atacante puede proporcionar un archivo de sombreador especialmente dise\\u00f1ado para activar esta vulnerabilidad. Esta vulnerabilidad puede ser activada desde el VMware invitado, afectando al host VMware.\"}]",
"id": "CVE-2019-5183",
"lastModified": "2024-11-21T04:44:30.510",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.0, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-01-25T18:15:12.490",
"references": "[{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964\", \"source\": \"talos-cna@cisco.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-843\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-5183\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2020-01-25T18:15:12.490\",\"lastModified\":\"2024-11-21T04:44:30.510\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de confusi\u00f3n de tipos explotable en el controlador AMD ATIDXX64.DLL, versiones 26.20.13031.10003, 26.20.13031.15006 y 26.20.13031.18002. Un sombreador de p\u00edxeles especialmente dise\u00f1ado puede causar un problema de confusi\u00f3n de tipos, conllevando a una potencial ejecuci\u00f3n de c\u00f3digo. Un atacante puede proporcionar un archivo de sombreador especialmente dise\u00f1ado para activar esta vulnerabilidad. Esta vulnerabilidad puede ser activada desde el VMware invitado, afectando al host VMware.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:amd:atidxx64:26.20.13031.10003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC82656D-2131-4934-9A1D-A51C78120B1E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:amd:atidxx64:26.20.13031.15006:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5723683-8C9E-444E-A657-31BCF5F7E25C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:amd:atidxx64:26.20.13031.18002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F23D439-AB74-4CCD-BDC3-4980B78193E8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:a:vmware:workstation:15.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83DF9A19-ED8A-4914-96FA-D156CA9AFBC5\"}]}]}],\"references\":[{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…