CVE-2019-6822 (GCVE-0-2019-6822)
Vulnerability from cvelistv5 – Published: 2019-07-15 20:46 – Updated: 2024-08-04 20:31
VLAI?
Summary
A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.
Severity ?
No CVSS data available.
CWE
- CWE-416 - Use After Free
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Zelio Soft | Zelio Soft 2 V5.2 and prior |
Affected:
Zelio Soft 2 V5.2 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.201Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "109100",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/109100"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-658/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-190-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Zelio Soft 2 V5.2 and prior",
"vendor": "Zelio Soft",
"versions": [
{
"status": "affected",
"version": "Zelio Soft 2 V5.2 and earlier"
}
]
}
],
"datePublic": "2019-07-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-22T19:21:50",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "109100",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/109100"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-658/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-190-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6822",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Zelio Soft 2 V5.2 and prior",
"version": {
"version_data": [
{
"version_value": "Zelio Soft 2 V5.2 and earlier"
}
]
}
}
]
},
"vendor_name": "Zelio Soft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "109100",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/109100"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-658/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-658/"
},
{
"name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-190-03",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-190-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6822",
"datePublished": "2019-07-15T20:46:39",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.201Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:zelio_soft_2:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"5.2\", \"matchCriteriaId\": \"8F717CDE-45B5-4D04-BDB7-65BC5CCBB17D\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.\"}, {\"lang\": \"es\", \"value\": \"Una CWE-416: Se presenta una vulnerabilidad de Uso de Memoria Previamente Liberada en Zelio Soft 2, versi\\u00f3n V5.2 y anteriores, que podr\\u00eda causar la ejecuci\\u00f3n de c\\u00f3digo remota al abrir un archivo de proyecto de Zelio Soft 2 especialmente dise\\u00f1ado.\"}]",
"id": "CVE-2019-6822",
"lastModified": "2024-11-21T04:47:13.350",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2019-07-15T21:15:10.587",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/109100\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-190-03\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-19-658/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securityfocus.com/bid/109100\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-190-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-19-658/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-416\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-416\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6822\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-07-15T21:15:10.587\",\"lastModified\":\"2024-11-21T04:47:13.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.\"},{\"lang\":\"es\",\"value\":\"Una CWE-416: Se presenta una vulnerabilidad de Uso de Memoria Previamente Liberada en Zelio Soft 2, versi\u00f3n V5.2 y anteriores, que podr\u00eda causar la ejecuci\u00f3n de c\u00f3digo remota al abrir un archivo de proyecto de Zelio Soft 2 especialmente dise\u00f1ado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:zelio_soft_2:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.2\",\"matchCriteriaId\":\"8F717CDE-45B5-4D04-BDB7-65BC5CCBB17D\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/109100\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-190-03\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-658/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securityfocus.com/bid/109100\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-190-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-658/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…