CVE-2020-12028 (GCVE-0-2020-12028)

Vulnerability from cvelistv5 – Published: 2020-07-20 15:17 – Updated: 2024-09-16 23:26
VLAI?
Summary
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
CWE
  • CWE-264 - PERMISSIONS, PRIVILEGES, AND ACCESS CONTROLS CWE-264
Assigner
Impacted products
Credits
Trend Micro’s Zero Day Initiative reported these vulnerabilities to Rockwell Automation
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FactoryTalk View SE",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to Rockwell Automation"
        }
      ],
      "datePublic": "2020-06-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-264",
              "description": "PERMISSIONS, PRIVILEGES, AND ACCESS CONTROLS CWE-264",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-20T17:06:18",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Rockwell Automation has released new versions of the affected products to mitigate the reported vulnerabilities. Affected users who are not able to apply the latest update are encouraged to seek additional mitigations or workarounds from the vendor\u2019s published guidelines in their security advisory.\nRockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs."
        }
      ],
      "source": {
        "advisory": "ICSA-20-170-05 Rockwell Automation FactoryTalk View SE",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk View SE",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-06-18T00:00:00.000Z",
          "ID": "CVE-2020-12028",
          "STATE": "PUBLIC",
          "TITLE": "Rockwell Automation FactoryTalk View SE"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "FactoryTalk View SE",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rockwell Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to Rockwell Automation"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "PERMISSIONS, PRIVILEGES, AND ACCESS CONTROLS CWE-264"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05"
            },
            {
              "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944",
              "refsource": "MISC",
              "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944"
            },
            {
              "name": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Rockwell Automation has released new versions of the affected products to mitigate the reported vulnerabilities. Affected users who are not able to apply the latest update are encouraged to seek additional mitigations or workarounds from the vendor\u2019s published guidelines in their security advisory.\nRockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs."
          }
        ],
        "source": {
          "advisory": "ICSA-20-170-05 Rockwell Automation FactoryTalk View SE",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12028",
    "datePublished": "2020-07-20T15:17:11.738641Z",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-09-16T23:26:08.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*\", \"matchCriteriaId\": \"4DDF668E-9D30-4588-8897-474014D746A5\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.\"}, {\"lang\": \"es\", \"value\": \"En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. Los usuarios deben seguir la gu\\u00eda que se encuentra en los art\\u00edculos 109056 y 1126943 de la base de conocimiento para configurar IPSec y/o HTTP\"}]",
      "id": "CVE-2020-12028",
      "lastModified": "2024-11-21T04:59:08.567",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.1, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:N\", \"baseScore\": 5.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2020-07-20T16:15:12.163",
      "references": "[{\"url\": \"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-264\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-12028\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-07-20T16:15:12.163\",\"lastModified\":\"2024-11-21T04:59:08.567\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.\"},{\"lang\":\"es\",\"value\":\"En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. Los usuarios deben seguir la gu\u00eda que se encuentra en los art\u00edculos 109056 y 1126943 de la base de conocimiento para configurar IPSec y/o HTTP\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.1,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:N\",\"baseScore\":5.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*\",\"matchCriteriaId\":\"4DDF668E-9D30-4588-8897-474014D746A5\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…