Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
Severity ?
6.8 (Medium)
CWE
Assigner
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Clinical Collaboration Platform |
Affected:
0 , < 12.2.1
(custom)
|
Credits
Northridge Hospital Medical Center reported these vulnerabilities to Philips.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:54.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Clinical Collaboration Platform",
"vendor": "Philips",
"versions": [
{
"lessThan": "12.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Northridge Hospital Medical Center reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\n\nexposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.\n\n\u003c/p\u003e"
}
],
"value": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\n\nexposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-16",
"description": "CWE-16",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-04T21:24:46.327Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003e\nPhilips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CVE-2020-16247.\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\u003cp\u003eUsers with questions regarding their specific Philips Clinical \nCollaboration Platform installations and new release eligibility should \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.usa.philips.com/healthcare/solutions/customer-service-solutions\"\u003ePhilips service support, or regional service support\u003c/a\u003e, or call 1-877-328-2808, option 4.\u003c/p\u003e\u003cp\u003eThe Philips advisory and the latest security information for Philips products are available at the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/productsecurity\"\u003ePhilips product security website\u003c/a\u003e.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CVE-2020-16247.\n\n\n\n\n\nUsers with questions regarding their specific Philips Clinical \nCollaboration Platform installations and new release eligibility should \ncontact Philips service support, or regional service support https://www.usa.philips.com/healthcare/solutions/customer-service-solutions , or call 1-877-328-2808, option 4.\n\nThe Philips advisory and the latest security information for Philips products are available at the Philips product security website https://www.philips.com/productsecurity ."
}
],
"source": {
"advisory": "ICSMA-20-261-01",
"discovery": "EXTERNAL"
},
"title": "Philips Clinical Collaboration Platform Configuration",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14506",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Philips Clinical Collaboration Platform",
"version": {
"version_data": [
{
"version_value": "Versions 12.2.1 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CROSS-SITE REQUEST FORGERY (CSRF) CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-16247",
"datePublished": "2020-09-18T17:55:24",
"dateReserved": "2020-07-31T00:00:00",
"dateUpdated": "2025-06-04T21:24:46.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"12.2.1\", \"matchCriteriaId\": \"53A1D5DF-AD61-4A42-8021-C0FFBCB98144\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.\"}, {\"lang\": \"es\", \"value\": \"Philips Clinical Collaboration Platform, versiones 12.2.1 y anteriores.\u0026#xa0;El producto expone un recurso a la esfera de control incorrecta, proporcionando a los actores no deseados un acceso inapropiado al recurso\"}]",
"id": "CVE-2020-16247",
"lastModified": "2024-11-21T05:07:01.237",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:N\", \"baseScore\": 3.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-09-18T18:15:17.113",
"references": "[{\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-16\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-668\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-16247\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-09-18T18:15:17.113\",\"lastModified\":\"2025-06-04T22:15:24.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \\n\\n\\nexposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.\"},{\"lang\":\"es\",\"value\":\"Philips Clinical Collaboration Platform, versiones 12.2.1 y anteriores.\u0026#xa0;El producto expone un recurso a la esfera de control incorrecta, proporcionando a los actores no deseados un acceso inapropiado al recurso\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.5,\"impactScore\":4.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:N\",\"baseScore\":3.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-16\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"12.2.1\",\"matchCriteriaId\":\"53A1D5DF-AD61-4A42-8021-C0FFBCB98144\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…