CVE-2020-26080 (GCVE-0-2020-26080)
Vulnerability from cvelistv5 – Published: 2020-11-18 17:40 – Updated: 2024-11-13 17:39
VLAI?
Summary
A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.
Severity ?
4.1 (Medium)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco IoT Field Network Director (IoT-FND) |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:49:06.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-26080",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-13T17:22:13.624381Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T17:39:03.072Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco IoT Field Network Director (IoT-FND)",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2020-11-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-18T17:40:46",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
}
],
"source": {
"advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
"defect": [
[
"CSCvt45294"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2020-11-18T16:00:00",
"ID": "CVE-2020-26080",
"STATE": "PUBLIC",
"TITLE": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IoT Field Network Director (IoT-FND)",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "4.1",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
}
]
},
"source": {
"advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
"defect": [
[
"CSCvt45294"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2020-26080",
"datePublished": "2020-11-18T17:40:46.724171Z",
"dateReserved": "2020-09-24T00:00:00",
"dateUpdated": "2024-11-13T17:39:03.072Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.6.1\", \"matchCriteriaId\": \"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la funcionalidad user management de Cisco IoT Field Network Director (FND), podr\\u00eda permitir a un atacante remoto autenticado administrar la informaci\\u00f3n de los usuarios en diferentes dominios en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado al dominio.\u0026#xa0;Un atacante podr\\u00eda explotar esta vulnerabilidad manipulando cargas \\u00fatiles JSON para apuntar a diferentes dominios en un sistema afectado.\u0026#xa0;Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante administrar la informaci\\u00f3n del usuario para usuarios en diferentes dominios en un sistema afectado\"}]",
"id": "CVE-2020-26080",
"lastModified": "2024-11-21T05:19:11.697",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"baseScore\": 4.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 1.4}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"baseScore\": 4.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:N/I:P/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-11-18T18:15:12.077",
"references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-26080\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2020-11-18T18:15:12.077\",\"lastModified\":\"2024-11-21T05:19:11.697\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la funcionalidad user management de Cisco IoT Field Network Director (FND), podr\u00eda permitir a un atacante remoto autenticado administrar la informaci\u00f3n de los usuarios en diferentes dominios en un sistema afectado.\u0026#xa0;La vulnerabilidad es debido a un control de acceso inapropiado al dominio.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad manipulando cargas \u00fatiles JSON para apuntar a diferentes dominios en un sistema afectado.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante administrar la informaci\u00f3n del usuario para usuarios en diferentes dominios en un sistema afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\",\"baseScore\":4.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":1.4}],\"cvssMetricV30\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\",\"baseScore\":4.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:P/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.6.1\",\"matchCriteriaId\":\"0D507A4F-4079-4B68-997E-88901E063348\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T15:49:06.995Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-26080\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T17:22:13.624381Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T17:25:57.512Z\"}}], \"cna\": {\"title\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 4.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco IoT Field Network Director (IoT-FND)\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-11-18T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-11-18T17:40:46\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.1\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco IoT Field Network Director (IoT-FND)\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-284\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-26080\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-11-18T16:00:00\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2020-26080\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-13T17:39:03.072Z\", \"dateReserved\": \"2020-09-24T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-11-18T17:40:46.724171Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…