CVE-2020-7560
Vulnerability from cvelistv5
Published
2020-12-11 00:52
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2020-343-01/ | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.451Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure\u2122 Control Expert software." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-123", "description": "CWE-123: Write-what-where Condition", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-11T00:52:30", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-01/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2020-7560", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions)", "version": { "version_data": [ { "version_value": "EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure\u2122 Control Expert software." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-123: Write-what-where Condition" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-01/", "refsource": "CONFIRM", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-01/" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2020-7560", "datePublished": "2020-12-11T00:52:30", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.451Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-7560\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-12-11T01:15:12.707\",\"lastModified\":\"2022-01-31T19:33:27.473\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure\u2122 Control Expert (all versions) and Unity Pro (former name of EcoStruxure\u2122 Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure\u2122 Control Expert software.\"},{\"lang\":\"es\",\"value\":\"Una CWE-123: Se presenta una vulnerabilidad de Condici\u00f3n Write-what-where en EcoStruxure\u2122 Control Expert (todas las versiones) y Unity Pro (nombre anterior de EcoStruxure\u2122 Control Expert) (todas las versiones), que podr\u00eda causar un bloqueo del software o una ejecuci\u00f3n de c\u00f3digo inesperada cuando se abre un archivo malicioso en el software EcoStruxure\u2122 Control Expert\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-123\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18E8CCC1-A467-4FEF-964D-8481EAE892EC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"51476F6C-7515-4DD4-8D3D-5E86C1EEFC06\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-343-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.