CVE-2020-7581
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.617Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:47", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-428: Unquoted Search Path or Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7581", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.617Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-7581\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-07-14T14:15:18.587\",\"lastModified\":\"2023-01-30T19:54:07.110\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3. 0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15.1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). Un componente dentro de la aplicaci\u00f3n afectada llama a un binario de ayuda con privilegios de SISTEMA durante el inicio mientras la ruta de llamada no est\u00e1 citada. Esto podr\u00eda permitir a un atacante local con privilegios administrativos ejecutar c\u00f3digo con privilegios de nivel SYSTEM\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.2},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-428\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-428\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2\",\"matchCriteriaId\":\"F33BF89C-F36E-4C8F-ABB9-579E2022DDA6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2\",\"matchCriteriaId\":\"1DCE5E06-B75F-4D21-96CC-70DD373B1811\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2\",\"matchCriteriaId\":\"C4DD5C57-5877-495C-A01E-747E5DCED9F7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA9BAFAE-C26A-4435-80C1-508F0A3EF768\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.3\",\"matchCriteriaId\":\"9DB2F53B-817C-41F3-9B52-85DE702ACCE5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_rd\\\\\u0026l:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE037602-C9E8-45D5-9A44-3B73052F478E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*\",\"matchCriteriaId\":\"DE74021F-CE57-42CC-8093-E1B0352410FA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D61D4B81-7F51-49BE-83DD-D2C28D23B0EA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"E6D968D9-2A64-4E1C-824F-6508AEC6789D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"66CB66B9-176E-4FA3-BC67-E7C5972A307C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CE934FDC-666F-4D9D-9C03-2896875F0A0D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA57190F-97BA-4D1D-BC73-F37162B775F9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.