CVE-2021-1586 (GCVE-0-2021-1586)
Vulnerability from cvelistv5 – Published: 2021-08-25 19:10 – Updated: 2024-11-07 22:02
VLAI?
Summary
A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.
Severity ?
8.6 (High)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco NX-OS System Software in ACI Mode |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T16:18:10.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-1586",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-07T21:54:28.309256Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-07T22:02:32.217Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco NX-OS System Software in ACI Mode",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2021-08-25T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-25T19:10:59",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
}
],
"source": {
"advisory": "cisco-sa-n9kaci-tcp-dos-YXukt6gM",
"defect": [
[
"CSCvw87983"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2021-08-25T16:00:00",
"ID": "CVE-2021-1586",
"STATE": "PUBLIC",
"TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS System Software in ACI Mode",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.6",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
}
]
},
"source": {
"advisory": "cisco-sa-n9kaci-tcp-dos-YXukt6gM",
"defect": [
[
"CSCvw87983"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2021-1586",
"datePublished": "2021-08-25T19:10:59.639835Z",
"dateReserved": "2020-11-13T00:00:00",
"dateUpdated": "2024-11-07T22:02:32.217Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:nx-os:15.0\\\\(2e\\\\):*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11E2E40A-CCD5-4CA7-826E-10923BED72E8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:nx-os:15.1\\\\(1h\\\\):*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C78C9E79-C6DC-4FE3-8B79-A9BEBED9A67D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0CD9C1F1-8582-4F67-A77D-97CBFECB88B8\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4283E433-7F8C-4410-B565-471415445811\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F80AB6FB-32FD-43D7-A9F1-80FA47696210\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D5B2E4C1-2627-4B9D-8E92-4B483F647651\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"557ED31C-C26A-4FAE-8B14-D06B49F7F08B\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11411BFD-3F4D-4309-AB35-A3629A360FB0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E663DE91-C86D-48DC-B771-FA72A8DF7A7C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A90184B3-C82F-4CE5-B2AD-97D5E4690871\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"40E40F42-632A-47DF-BE33-DC25B826310B\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4AB89849-6DA4-4C9D-BC3F-EE0E41FD1901\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C47F6BF9-2ADB-41A4-8D7D-8BB00141BB23\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BBEF7F26-BB47-44BD-872E-130820557C23\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"07DE6F63-2C7D-415B-8C34-01EC05C062F3\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F423E45D-A6DD-4305-9C6A-EAB26293E53A\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"102F91CD-DFB6-43D4-AE5B-DA157A696230\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E952A96A-0F48-4357-B7DD-1127D8827650\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F70D81F1-8B12-4474-9060-B4934D8A3873\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5394DE31-3863-4CA9-B7B1-E5227183100D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7349D69B-D8FA-4462-AA28-69DD18A652D9\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FE4BB834-2C00-4384-A78E-AF3BCDDC58AF\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B0D30D52-837F-4FDA-B8E5-A9066E9C6D2F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CE49B45-F2E9-491D-9C29-1B46E9CE14E2\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B1CC5F78-E88B-4B82-9E3E-C73D3A49DE26\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"91231DC6-2773-4238-8C14-A346F213B5E5\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2DF88547-BAF4-47B0-9F60-80A30297FCEB\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"113772B6-E9D2-4094-9468-3F4E1A87D07D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C45A38D6-BED6-4FEF-AD87-A1E813695DE0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F1FC2B1F-232E-4754-8076-CC82F3648730\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CDD27C9-5EAF-4956-8AB7-740C84C9D4FC\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17C7E3DB-8E1A-47AD-B1C5-61747DC0CFB9\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2CF467E2-4567-426E-8F48-39669E0F514C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"63842B25-8C32-4988-BBBD-61E9CB09B4F3\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"68EA1FEF-B6B6-49FE-A0A4-5387F76303F8\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4364ADB9-8162-451D-806A-B98924E6B2CF\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B53BCB42-ED61-4FCF-8068-CB467631C63C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"49E0371B-FDE2-473C-AA59-47E1269D050F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"489D11EC-5A18-4F32-BC7C-AC1FCEC27222\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1BC5293E-F2B4-46DC-85DA-167EA323FCFD\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EA022E77-6557-4A33-9A3A-D028E2DB669A\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DDC2F709-AFBE-48EA-A3A2-DA1134534FB6\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en las configuraciones de red Multi-Pod o Multi-Site para Cisco Nexus 9000 Series Fabric Switches en el modo Application Centric Infrastructure (ACI) podr\\u00eda permitir a un atacante remoto no autenticado reiniciar inesperadamente el dispositivo, resultando en una condici\\u00f3n de denegaci\\u00f3n de servicio (DoS). Esta vulnerabilidad se presenta porque el tr\\u00e1fico TCP enviado a un puerto espec\\u00edfico en un dispositivo afectado no se sanea apropiadamente. Un atacante podr\\u00eda explotar esta vulnerabilidad mediante el env\\u00edo de datos TCP dise\\u00f1ados a un puerto espec\\u00edfico que est\\u00e1 escuchando en una direcci\\u00f3n IP p\\u00fablica para la configuraci\\u00f3n de Multi-Pod o Multi-Site. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante causar que el dispositivo se reinicie inesperadamente, resultando en una condici\\u00f3n de DoS.\"}]",
"id": "CVE-2021-1586",
"lastModified": "2024-11-21T05:44:40.963",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\", \"baseScore\": 8.6, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\", \"baseScore\": 8.6, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-08-25T20:15:11.237",
"references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-345\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-345\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-1586\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2021-08-25T20:15:11.237\",\"lastModified\":\"2024-11-21T05:44:40.963\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en las configuraciones de red Multi-Pod o Multi-Site para Cisco Nexus 9000 Series Fabric Switches en el modo Application Centric Infrastructure (ACI) podr\u00eda permitir a un atacante remoto no autenticado reiniciar inesperadamente el dispositivo, resultando en una condici\u00f3n de denegaci\u00f3n de servicio (DoS). Esta vulnerabilidad se presenta porque el tr\u00e1fico TCP enviado a un puerto espec\u00edfico en un dispositivo afectado no se sanea apropiadamente. Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de datos TCP dise\u00f1ados a un puerto espec\u00edfico que est\u00e1 escuchando en una direcci\u00f3n IP p\u00fablica para la configuraci\u00f3n de Multi-Pod o Multi-Site. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante causar que el dispositivo se reinicie inesperadamente, resultando en una condici\u00f3n de DoS.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-345\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-345\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:15.0\\\\(2e\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11E2E40A-CCD5-4CA7-826E-10923BED72E8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:15.1\\\\(1h\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C78C9E79-C6DC-4FE3-8B79-A9BEBED9A67D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CD9C1F1-8582-4F67-A77D-97CBFECB88B8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4283E433-7F8C-4410-B565-471415445811\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F80AB6FB-32FD-43D7-A9F1-80FA47696210\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5B2E4C1-2627-4B9D-8E92-4B483F647651\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"557ED31C-C26A-4FAE-8B14-D06B49F7F08B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11411BFD-3F4D-4309-AB35-A3629A360FB0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E663DE91-C86D-48DC-B771-FA72A8DF7A7C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A90184B3-C82F-4CE5-B2AD-97D5E4690871\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40E40F42-632A-47DF-BE33-DC25B826310B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4AB89849-6DA4-4C9D-BC3F-EE0E41FD1901\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C47F6BF9-2ADB-41A4-8D7D-8BB00141BB23\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BBEF7F26-BB47-44BD-872E-130820557C23\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07DE6F63-2C7D-415B-8C34-01EC05C062F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F423E45D-A6DD-4305-9C6A-EAB26293E53A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"102F91CD-DFB6-43D4-AE5B-DA157A696230\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E952A96A-0F48-4357-B7DD-1127D8827650\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F70D81F1-8B12-4474-9060-B4934D8A3873\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5394DE31-3863-4CA9-B7B1-E5227183100D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7349D69B-D8FA-4462-AA28-69DD18A652D9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE4BB834-2C00-4384-A78E-AF3BCDDC58AF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0D30D52-837F-4FDA-B8E5-A9066E9C6D2F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CE49B45-F2E9-491D-9C29-1B46E9CE14E2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1CC5F78-E88B-4B82-9E3E-C73D3A49DE26\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"91231DC6-2773-4238-8C14-A346F213B5E5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DF88547-BAF4-47B0-9F60-80A30297FCEB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"113772B6-E9D2-4094-9468-3F4E1A87D07D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C45A38D6-BED6-4FEF-AD87-A1E813695DE0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1FC2B1F-232E-4754-8076-CC82F3648730\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CDD27C9-5EAF-4956-8AB7-740C84C9D4FC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17C7E3DB-8E1A-47AD-B1C5-61747DC0CFB9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CF467E2-4567-426E-8F48-39669E0F514C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63842B25-8C32-4988-BBBD-61E9CB09B4F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68EA1FEF-B6B6-49FE-A0A4-5387F76303F8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4364ADB9-8162-451D-806A-B98924E6B2CF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B53BCB42-ED61-4FCF-8068-CB467631C63C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49E0371B-FDE2-473C-AA59-47E1269D050F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"489D11EC-5A18-4F32-BC7C-AC1FCEC27222\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BC5293E-F2B4-46DC-85DA-167EA323FCFD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA022E77-6557-4A33-9A3A-D028E2DB669A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDC2F709-AFBE-48EA-A3A2-DA1134534FB6\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"name\": \"20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T16:18:10.396Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-1586\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-07T21:54:28.309256Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-07T21:45:34.480Z\"}}], \"cna\": {\"title\": \"Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability\", \"source\": {\"defect\": [[\"CSCvw87983\"]], \"advisory\": \"cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco NX-OS System Software in ACI Mode\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2021-08-25T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"name\": \"20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-345\", \"description\": \"CWE-345\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2021-08-25T19:10:59\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"8.6\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\"}}, \"source\": {\"defect\": [[\"CSCvw87983\"]], \"advisory\": \"cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco NX-OS System Software in ACI Mode\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM\", \"name\": \"20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-345\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-1586\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2021-08-25T16:00:00\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2021-1586\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-07T22:02:32.217Z\", \"dateReserved\": \"2020-11-13T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2021-08-25T19:10:59.639835Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…