GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2021-1586

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-1586",
    "description": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.",
    "id": "GSD-2021-1586"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-1586"
      ],
      "details": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.",
      "id": "GSD-2021-1586",
      "modified": "2023-12-13T01:23:23.770690Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@cisco.com",
        "DATE_PUBLIC": "2021-08-25T16:00:00",
        "ID": "CVE-2021-1586",
        "STATE": "PUBLIC",
        "TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Cisco NX-OS System Software in ACI Mode ",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Cisco"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
          }
        ]
      },
      "exploit": [
        {
          "lang": "eng",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
        }
      ],
      "impact": {
        "cvss": {
          "baseScore": "8.6",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H ",
          "version": "3.0"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-345"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
            "refsource": "CISCO",
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
          }
        ]
      },
      "source": {
        "advisory": "cisco-sa-n9kaci-tcp-dos-YXukt6gM",
        "defect": [
          [
            "CSCvw87983"
          ]
        ],
        "discovery": "INTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:15.0\\(2e\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:15.1\\(1h\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx3p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2021-1586"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-345"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210825 Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability",
              "refsource": "CISCO",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-n9kaci-tcp-dos-YXukt6gM"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 4.0
        }
      },
      "lastModifiedDate": "2021-09-02T17:18Z",
      "publishedDate": "2021-08-25T20:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…